HFHideki Fujii

Hideki Fujii

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hideki Fujii has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Total Hip Arthroplasty for Crowe III/IV Hip Dysplasia With Oblique Subtrochanteric Shortening Osteotomy and S‐ROM‐A Modular Stem: 10‐Year Outcomes

    by Tetsuo Hayama, Motoi Takahashi, Takuya Otani, Hideki Fujii, Yasuhiko Kawaguchi, Toshiomi Abe, Mitsuru Saito

    Background: High dislocation due to developmental dysplasia of the hip (DDH), classified as Crowe type III or IV, presents significant challenges in total hip arthroplasty (THA), particularly in preventing nerve complications while restoring leg length.Aim: This study aimed to evaluate the clinical and radiographic outcomes of primary THA using an S‐ROM‐A modular stem with oblique subtrochanteric shortening osteotomy in patients with high hip dislocation; to identify the advantages, limitations, and possible countermeasures of this surgical approach.Patients and Methods: Subjects were 45 hips (37 patients) with high hip dislocation (Crowe III/IV) treated by primary THA using an S‐ROM‐A stem, with femoral shortening osteotomy performed at our institution. Outcomes 3 years after surgery were examined in 100% of the subjects. Postoperative complications and functional and radiographic outcomes were investigated.Results: The mean age at surgery was 65 years and the mean duration of postoperative follow‐up was 10.7 ± 3.4 years. There were no cases of postoperative infection, symptomatic pulmonary embolism, or neurological complications in the legs. Early postoperative dislocation occurred in two hips (4%, resolved conservatively) and osteotomy site nonunion in one hip (2%). Repeat surgery was required in only this case of nonunion (2%). The hip function score was significantly improved postoperatively. Leg lengthening after surgery was 0–56 mm (mean, 28 mm). Examination of radiographs revealed that it took 12 weeks for bone union at the osteotomy site in all hips except for the one hip with nonunion. No stem subsidence was found postoperatively, and “fixation by bone ingrowth” was achieved at the final follow‐up examination in all hips (100%), including the one that required repeat surgery.Conclusion: THA using an S‐ROM‐A modular stem with oblique subtrochanteric shortening osteotomy provided favorable mid‐term outcomes in patients with Crowe III/IV DDH. No neurological complications occurred, and functional and radiographic improvements were substantial. Our method, which emphasizes intraoperative sciatic nerve palpation for individualized leg lengthening, may serve as a practical and safe alternative to more complex monitoring systems. Further research incorporating objective intraoperative monitoring may help standardize this approach.


  • Open Access

    Do radiological findings around the Fitmore stem change over time?

    by Hideki Fujii, Tetsuo Hayama, Toshiomi Abe, Motoi Takahashi, Ayano Amagami, Yohei Matsushita, Takuya Otani, Mitsuru Saito

    Aims Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population. Methods This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either radiolucent lines (RLLs), cortical hypertrophy (CH), or atrophy (AT) appeared or not on the one-year radiograph. Further, three-year radiographs of eligible cases were reviewed to determine changes such as, disappeared (D), improved (I), stable (S), and progression (P). Additionally, bone condensation (BC) was assessed on the three-year radiograph. Results CH was observed in 49 hips (21.1%), AT was observed in 63 hips (27.2%), and RLLs were observed in 34 hips (14.7%) at one year postoperatively. Among 34 hips with RLLs, 70.6% showed change of either D or I on the three-year radiograph. BC was observed in younger patients more frequently. Conclusion The Fitmore stem works well in a Japanese population with favourable radiological change on hips with RLLs. Longer-term follow-up is required to determine clinical relevance. Cite this article: Bone Jt Open 2022;3(1):20–28.


  • Open Access

    Improving MiniHip femoral prosthesis positioning using a cross‐laser projection system in total hip arthroplasty by an anterolateral supine approach

    by Hideki Fujii, Tetsuo Hayama, Toshiomi Abe, Motoi Takahashi, Yohei Matsushita, Ryuichi Sato, Takuya Otani, Mitsuru Saito

    Background: The authors developed a cross‐laser projection system (CLP) to place a femoral neck‐sparing short stem using the minimally invasive anterolateral supine approach in total hip arthroplasty. This study aimed to verify the utility of CLP.Methods: Thirty joints were assessed with the MiniHip (Corin). The authors compared femoral component implantation with a patient‐specific femoral osteotomy guide (PSG) for the femoral neck‐cut (PSG group), with the CLP attached to the rasp handle to irradiate the cross‐laser to the target of PSG (CLP group), and without PSG or CLP (control group).Results: In the CLP group, the positional deviation of anteversion, anterior/posterior tilt and varus/valgus placement of the stem postoperatively were 1.8° ± 0.2°, 2.0° ± 2.0° and 2.0° ± 0.1°, respectively. The positional deviation of anteversion (p < 0.001) and anterior/posterior tilt (p = 0.036) were significantly smaller than those in the other groups.Conclusions: CLP improves the accuracy of MiniHip femoral prosthesis placement.


  • Open Access

    Preventing postoperative prosthetic joint dislocation by repairing obturator externus in total hip arthroplasty performed via the posterior approach

    by Hideki Fujii, Takuya Otani, Yasuhiko Kawaguchi, Tetsuo Hayama, Toshiomi Abe, Motoi Takahashi, Mitsuru Saito

    Background: In total hip arthroplasty performed via the posterior approach, repairing the posterior soft tissues is a conventional method for preventing postoperative prosthetic joint dislocation. The aim of this study was to verify whether obturator externus repair played the main role and what was the mechanism of the repair preventing the dislocation. Methods: Included were 188 patients who underwent primary cementless total hip arthroplasty via the posterior approach. The patients were divided into a repair group (n = 94) and a non-repair group (n = 94). Patients of repair group received additional obturator externus repair while patients of non-repair group did not. The range of motion of hip joint was assessed before and after operation. Data were compared between the two groups. A p value < 0.05 was considered statistically significant. Results: Before operation and under anesthesia, with regard to internal rotation of hip joint, the mean values of repair and non-repair groups were 24° ± 16/28° ± 15 (p = 0.2933). The mean values of the groups were 13° ± 8/15° ± 9 immediately after repair (p = 0.5672). Range of internal rotation 1 year after operation were 15° ± 8/19° ± 9 (p = 0.0139). Specifically, the values in repair group were lower than those in non-repair group. During a 5-year period of postoperative follow-up, hip joint dislocation occurred in one patient of non-repair group. No dislocation was observed in repair group. Conclusion: When THA is performed via the posterior approach, repairing the obturator externus may decrease the risk of postoperative prosthetic joint dislocation by reinforcing the posterior soft tissues of the hip joint. Level of evidence: Therapeutic study, Level IVa.


  • Open Access

    Clinical results of a short stem with flat tapered wedge design in primary total hip arthroplasty for hip dysplasia in Asians

    by Tetsuo Hayama, Takuya Otani, Hideki Fujii, Yasuhiko Kawaguchi, Toshiomi Abe, Motoi Takahashi, Mitsuru Saito

    Background: Cementless femoral reconstruction is challenging in hip dysplasia due to deformity of the proximal femur causing insufficient stem fixation and/or inadequate neck anteversion. Strategies to address these problems include the use of a modular stem or a distal fixation stem, but both stems have some characteristic disadvantages. Methods: We studied the postoperative clinical outcomes in primary total hip arthroplasty in 257 hips using the flat tapered wedge short femoral stem for hip dysplasia in an Asian population (postoperative follow-up period: 2 years to 6 years and 11 months; mean 4 years and 5 months). We took advantage of the characteristic of high flexibility in stem placement because of its low volume, positioning it while performing some varus/valgus and rotational alignment adjustments. Results: Favorable clinical functional outcomes were obtained, including the radiographic outcome of biological fixation achieved in all stems. Regarding complications, there was no case of split fracture of the femoral calcar region during stem insertion, and the rate of postoperative dislocation was also low at 0.4% (1 case). In the pre- and postoperative computed tomography measurements, the variability in stem anteversion postoperatively was significantly reduced compared to preoperative anatomical anteversion. Conclusion: This flat-shaped short low-volume stem likely has high flexibility in positioning in cases of hip dysplasia and can be easily positioned to avoid fractures while still achieving secure fixation.


  • Open Access

    Treatment of periprosthetic hip infection with retention of a well-fixed stem: six to 13-year outcomes

    by Takuya Otani, Hideki Fujii, Yasuhiko Kawaguchi, Tetsuo Hayama, Toshiomi Abe, Motoi Takahashi, Keishi Marumo

    Background Treatment of periprosthetic joint infection (PJI) is challenging, generally requiring complete implant removal. However, recently reported treatments involve partial retention of implants because of the severe local and systemic burden on the patients and difficulties in functional preservation. Long-term results should be evaluated because of the risk of residual biofilm on the retained implant and late infection recurrence. We evaluated 6 to 13-year clinical outcomes of two-stage treatment of chronic PJI retaining well-fixed cementless stems. Methods Among 36 surgeries for deep infection following hip arthroplasty performed from 2004 to 2011, six hips had a well-fixed and well-functioning cementless stem. These six hips were all chronic PJI and were treated without stem removal. The first-stage surgery involved acetabular cup removal and reconstruction by filling the acetabular defect with antibiotic-loaded acrylic cement, creating a socket-like hemispherical dent, and reducing the retained femoral head to this dent. After confirming infection eradication the second-stage acetabular reconstruction was performed. One patient died of an unrelated noninfective cause 1 year after the operation. Clinical outcomes of the remaining five patients were followed for 6 to 13 years. Results Between the two surgeries (range; 2-5 months), patients underwent active range-of-motion and ambulation exercises. No dislocation was found during the interval. No recurrence of infection was found and good functional outcomes and radiographic findings were observed during the average follow-up of 109 months in all five patients. Conclusions Two-stage treatment with retention of a well-fixed stem may minimize local and systemic burden of the patient and enhance functional preservation while obtaining long-term infection control. Although further study could establish the effectiveness and indications for this treatment option, currently used indications should be carefully evaluated considering factors including local and systemic conditions of the patient, implant fixation status, and type of bacteria.