Use of a 3 French system for balloon aortic valvuloplasty in infants
Authors:
- 26 August 2005
- journal article
- pediatric and-congenital-heart-disease
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 66 (2) , 254-257
Abstract
For infants with valvar aortic stenosis, balloon aortic valvuloplasty has supplanted surgical valvotomy as the initial treatment of choice at most institutions. Technological innovations have resulted in further miniaturization of balloon dilation catheters, allowing this procedure to be performed through smaller sheath sizes. Currently, the Tyshak-Mini balloon dilation catheter (B. Braun Medical) allows passage of up to an 8 mm dilation balloon catheter through a 3 Fr hemostatic sheath. The efficacy of this system for the treatment of valvar aortic stenosis in infants less than 6 months of age was evaluated in 20 patients undergoing 22 procedures. Mean age at the time of intervention was 26 ± 46 days. Mean transvalvar gradient was 76 ± 22 mm Hg prior to balloon dilation. Following balloon valvuloplasty, residual gradient was 26 ± 12 mm Hg, reflecting a mean change in peak-to-peak gradient of 49 ± 19 mm Hg. Postintervention increase in aortic insufficiency was one grade or less in 19/22 procedures, two grades in 2 procedures, and three grades in 1 procedure. There were no significant vascular complications reported immediately following the procedure. Repeat valvuloplasty was performed in three patients in which the 3 Fr system was used in two patients. The 3 Fr system for balloon aortic valvuloplasty in infants less than 6 months of age is effective and safe.Keywords
This publication has 24 references indexed in Scilit:
- Anterograde balloon valvuloplasty for the treatment of neonatal critical valvar aortic stenosisCatheterization and Cardiovascular Interventions, 2002
- Aortic valve regurgitation after surgical versus percutaneous balloon valvotomy for congenital aortic valve stenosisThe American Journal of Cardiology, 1996
- Midterm results of balloon dilation of congenital aortic stenosis: Predictors of successJACC, 1996
- Independent predictors of immediate results of percutaneous balloon aortic valvotomy in childhoodThe American Journal of Cardiology, 1996
- Effectiveness of balloon valvuloplasty in the young adult with congenital aortic stenosisCatheterization and Cardiovascular Diagnosis, 1995
- Balloon aortic valvuloplasty in the young adult with congenital aortic stenosisThe American Journal of Cardiology, 1994
- Balloon aortic valvuloplasty: Results of the Valvuloplasty and Angioplasty of Congenital Anomalies RegistryThe American Journal of Cardiology, 1990
- Balloon dilatation of congenital aortic valve stenosis in infants and children: short term and intermediate results.Heart, 1989
- Successful balloon valvuloplasty for neonatal critical aortic stenosisAmerican Heart Journal, 1986
- Aortic balloon valvuloplastyAmerican Heart Journal, 1983