A High-Fidelity and Micro-anatomically Accurate 3D Finite Element Model for Simulations of Functional Mitral Valve
- 1 January 2013
- book chapter
- Published by Springer Nature
- Vol. 7945, 416-424
Abstract
Promising mitral valve (MV) repair concepts include leaflet augmentation and saddle shaped annuloplasty, and recent long-term studies have indicated that excessive tissue stress and the resulting strain-induced tissue failure are important etiologic factors leading to the recurrence of significant MR after repair. In the present work, we are aiming at developing a high-fidelity computational framework, incorporating detailed collagen fiber architecture, accurate constitutive models for soft valve tissues, and micro-anatomically accurate valvular geometry, for simulations of functional mitral valves which allows us to investigate the organ-level mechanical responses due to physiological loadings. This computational tools also provides a means, with some extension in the future, to help the understanding of the connection between the repair-induced altered stresses/strains and valve functions, and ultimately to aid in the optimal design of MV repair procedure with better performance and durability.Keywords
This publication has 22 references indexed in Scilit:
- Spline Based Microstructural Mapping for Soft Biological Tissues: Application to Aortic Valves2013
- Finite Element Modeling of Mitral Valve Dynamic Deformation Using Patient-Specific Multi-Slices Computed Tomography ScansAnnals of Biomedical Engineering, 2012
- Mitral valve dynamics in structural and fluid–structure interaction modelsMedical Engineering & Physics, 2010
- Finite element analysis of the mitral apparatus: annulus shape effect and chordal force distributionBiomechanics and Modeling in Mechanobiology, 2008
- Fluid–structure interaction models of the mitral valve: function in normal and pathological statesPhilosophical Transactions of the Royal Society B: Biological Sciences, 2007
- Biaixal Stress–Stretch Behavior of the Mitral Valve Anterior Leaflet at Physiologic Strain RatesAnnals of Biomedical Engineering, 2006
- Simulated Bioprosthetic Heart Valve Deformation under Quasi-Static LoadingJournal of Biomechanical Engineering, 2005
- In Vitro Dynamic Strain Behavior of the Mitral Valve Posterior LeafletJournal of Biomechanical Engineering, 2005
- The aortic valve microstructure: Effects of transvalvular pressureJournal of Biomedical Materials Research, 1998
- Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localizationThe Journal of Thoracic and Cardiovascular Surgery, 1996