Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Open Access
- 19 June 2023
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (7) , e14074
Abstract
Purpose: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.Methods: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.Results: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.Conclusion: Protocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.Keywords
This publication has 14 references indexed in Scilit:
- Photon-counting Detector CT: System Design and Clinical Applications of an Emerging TechnologyRadioGraphics, 2019
- Photon-counting CT: Technical Principles and Clinical ProspectsRadiology, 2018
- 150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography TechnologyInvestigative Radiology, 2018
- Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom StudyRadiology, 2018
- Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image setsPhysics in Medicine & Biology, 2017
- Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography systemJournal of Medical Imaging, 2016
- Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose LevelsInvestigative Radiology, 2016
- Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector arrayPhysics in Medicine & Biology, 2016
- Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical ApplicationsRadiology, 2015
- Vision 20/20: Single photon counting x‐ray detectors in medical imagingMedical Physics, 2013