Zaki Ahmed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zaki Ahmed has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
- Daehun Kang
Department of Radiology, Mayo Clinic, Rochester, MN
4 shared publications - Ives R. Levesque
Medical Physics Unit McGill University Montréal Québec Canada
4 shared publications - John Huston
Department of Radiology Mayo Clinic Rochester Minnesota USA
4 shared publications - Matt Bernstein
Department of Radiology Mayo Clinic Rochester Minnesota USA
4 shared publications - Myung-Ho In
Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA
4 shared publications - Nolan K. Meyer
Mayo Clinic, Rochester, MN, USA
4 shared publications
Latest Publications
- Open Access
- 19 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 1803-1821
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Purpose: has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.Methods: A framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.Results: Across the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.Conclusions: This study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
- 19 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 1803-1821
Open AccessThe ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Purpose: has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.Methods: A framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.Results: Across the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.Conclusions: This study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
- Open Access
- 13 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 1761-1773
A community‐endorsed open‐source lexicon for contrast agent–based perfusion MRI: A consensus guidelines report from the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI)
This manuscript describes the ISMRM OSIPI (Open Science Initiative for Perfusion Imaging) lexicon for dynamic contrast‐enhanced and dynamic susceptibility‐contrast MRI. The lexicon was developed by Taskforce 4.2 of OSIPI to provide standardized definitions of commonly used quantities, models, and analysis processes with the aim of reducing reporting variability. The taskforce was established in February 2020 and consists of medical physicists, engineers, clinicians, data and computer scientists, and DICOM (Digital Imaging and Communications in Medicine) standard experts. Members of the taskforce collaborated via a slack channel and quarterly virtual meetings. Members participated by defining lexicon items and reporting formats that were reviewed by at least two other members of the taskforce. Version 1.0.0 of the lexicon was subject to open review from the wider perfusion imaging community between January and March 2022, and endorsed by the Perfusion Study Group of the ISMRM in the summer of 2022. The initial scope of the lexicon was set by the taskforce and defined such that it contained a basic set of quantities, processes, and models to enable users to report an end‐to‐end analysis pipeline including kinetic model fitting. We also provide guidance on how to easily incorporate lexicon items and definitions into free‐text descriptions (e.g., in manuscripts and other documentation) and introduce an XML‐based pipeline encoding format to encode analyses using lexicon definitions in standardized and extensible machine‐readable code. The lexicon is designed to be open‐source and extendable, enabling ongoing expansion of its content. We hope that widespread adoption of lexicon terminology and reporting formats described herein will increase reproducibility within the field.
- 13 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 1761-1773
Open AccessA community‐endorsed open‐source lexicon for contrast agent–based perfusion MRI: A consensus guidelines report from the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI)
This manuscript describes the ISMRM OSIPI (Open Science Initiative for Perfusion Imaging) lexicon for dynamic contrast‐enhanced and dynamic susceptibility‐contrast MRI. The lexicon was developed by Taskforce 4.2 of OSIPI to provide standardized definitions of commonly used quantities, models, and analysis processes with the aim of reducing reporting variability. The taskforce was established in February 2020 and consists of medical physicists, engineers, clinicians, data and computer scientists, and DICOM (Digital Imaging and Communications in Medicine) standard experts. Members of the taskforce collaborated via a slack channel and quarterly virtual meetings. Members participated by defining lexicon items and reporting formats that were reviewed by at least two other members of the taskforce. Version 1.0.0 of the lexicon was subject to open review from the wider perfusion imaging community between January and March 2022, and endorsed by the Perfusion Study Group of the ISMRM in the summer of 2022. The initial scope of the lexicon was set by the taskforce and defined such that it contained a basic set of quantities, processes, and models to enable users to report an end‐to‐end analysis pipeline including kinetic model fitting. We also provide guidance on how to easily incorporate lexicon items and definitions into free‐text descriptions (e.g., in manuscripts and other documentation) and introduce an XML‐based pipeline encoding format to encode analyses using lexicon definitions in standardized and extensible machine‐readable code. The lexicon is designed to be open‐source and extendable, enabling ongoing expansion of its content. We hope that widespread adoption of lexicon terminology and reporting formats described herein will increase reproducibility within the field.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Benefits of echo combination for high-spatial-resolution ME resting state FMRI on a compact 3T scanner
For multi-echo EPI, the T2*-weighted echo combination (T2EC) is a commonly used pre-processing step to boost the data quality. We assessed the benefit of T2EC in high-spatial-resolution multi-echo fMRI with explained variances and functional connectivity detectability. The performance was evaluated and compared with single-echo EPI for resting state fMRI on a compact 3T scanner with high-performance gradients. It was shown that a large portion of unwanted signal variance was globally suppressed through T2EC. Multi-echo acquisition shows improved image intensity and enhanced functional sensitivity in brain regions affected by signal-dropout.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Benefits of echo combination for high-spatial-resolution ME resting state FMRI on a compact 3T scanner
For multi-echo EPI, the T2*-weighted echo combination (T2EC) is a commonly used pre-processing step to boost the data quality. We assessed the benefit of T2EC in high-spatial-resolution multi-echo fMRI with explained variances and functional connectivity detectability. The performance was evaluated and compared with single-echo EPI for resting state fMRI on a compact 3T scanner with high-performance gradients. It was shown that a large portion of unwanted signal variance was globally suppressed through T2EC. Multi-echo acquisition shows improved image intensity and enhanced functional sensitivity in brain regions affected by signal-dropout.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Comparison of different multiband acceleration factors on rhyming-task fMRI on a compact 3T scanner
Multiband acquisition can improve the temporal resolution of task-based fMRI at the cost of increased noise and artifacts. The optimal multiband acceleration depends on the task being studied, specific imaging protocol, and hardware involved. In the current work, multiband acceleration factors of 4, 5, and 6 were compared for a rhyming-task fMRI study using a 32-channel head coil on a compact 3T scanner with high-performance gradients. Multiband factors of 4 and 6 provided significant improvement over no acceleration, whereas a multiband factor of 5 was inconsistent and did not provide a significant improvement in half of the volunteer cohort.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Comparison of different multiband acceleration factors on rhyming-task fMRI on a compact 3T scanner
Multiband acquisition can improve the temporal resolution of task-based fMRI at the cost of increased noise and artifacts. The optimal multiband acceleration depends on the task being studied, specific imaging protocol, and hardware involved. In the current work, multiband acceleration factors of 4, 5, and 6 were compared for a rhyming-task fMRI study using a 32-channel head coil on a compact 3T scanner with high-performance gradients. Multiband factors of 4 and 6 provided significant improvement over no acceleration, whereas a multiband factor of 5 was inconsistent and did not provide a significant improvement in half of the volunteer cohort.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Improved Fidelity for Resting-State Connectivity Measurements in High-Spatial-Resolution ME-fMRI on a Compact 3T Scanner
Through echo-combination, multi-echo echo-planar-imaging (ME-EPI) has shown improved performance for fMRI over single-echo (SE)-EPI. The high-performance gradients on a compact 3T scanner enable whole-brain high-spatial-resolution ME-EPI with reasonable echo times and comparable TR to SE-EPI. To evaluate the fidelity of the ME-EPI sequence in resting state fMRI and compare with that of SE-EPI sequence, seed-based and ICA-based functional connectivity (FC) analyses were applied to evaluate scan-time-dependency and accuracy improvement. ME-EPI extracted more and stronger FCs in seed-based connectivity analysis and produced higher sensitivity and accuracy in ICA-based method, compared to SE-EPI.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Improved Fidelity for Resting-State Connectivity Measurements in High-Spatial-Resolution ME-fMRI on a Compact 3T Scanner
Through echo-combination, multi-echo echo-planar-imaging (ME-EPI) has shown improved performance for fMRI over single-echo (SE)-EPI. The high-performance gradients on a compact 3T scanner enable whole-brain high-spatial-resolution ME-EPI with reasonable echo times and comparable TR to SE-EPI. To evaluate the fidelity of the ME-EPI sequence in resting state fMRI and compare with that of SE-EPI sequence, seed-based and ICA-based functional connectivity (FC) analyses were applied to evaluate scan-time-dependency and accuracy improvement. ME-EPI extracted more and stronger FCs in seed-based connectivity analysis and produced higher sensitivity and accuracy in ICA-based method, compared to SE-EPI.
- Open Access
- 19 June 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (7) , e14074
Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Purpose: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.Methods: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.Results: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.Conclusion: Protocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
- 19 June 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (7) , e14074
Open AccessEstablishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Purpose: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.Methods: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.Results: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.Conclusion: Protocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
- Open Access
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.
Open AccessImproved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.
- Top Cited PapersOpen Access
- 12 October 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (66) , 3669
TE-dependent analysis of multi-echo fMRI with tedana
- 12 October 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (66) , 3669
Top Cited PapersOpen AccessTE-dependent analysis of multi-echo fMRI with tedana
- 8 August 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (1) , 286-298
Pharmacokinetic modeling of dynamic contrast‐enhanced MRI using a reference region and input function tail
Purpose: Quantitative analysis of dynamic contrast‐enhanced MRI (DCE‐MRI) requires an arterial input function (AIF) which is difficult to measure. We propose the reference region and input function tail (RRIFT) approach which uses a reference tissue and the washout portion of the AIF.Methods: RRIFT was evaluated in simulations with 100 parameter combinations at various temporal resolutions (5‐30 s) and noise levels (σ = 0.01‐0.05 mM). RRIFT was compared against the extended Tofts model (ETM) in 8 studies from patients with glioblastoma multiforme. Two versions of RRIFT were evaluated: one using measured patient‐specific AIF tails, and another assuming a literature‐based AIF tail.Results: RRIFT estimated the transfer constant and interstitial volume with median errors within 20% across all simulations. RRIFT was more accurate and precise than the ETM at temporal resolutions slower than 10 s. The percentage error of had a median and interquartile range of −9 ± 45% with the ETM and −2 ± 17% with RRIFT at a temporal resolution of 30 s under noiseless conditions. RRIFT was in excellent agreement with the ETM in vivo, with concordance correlation coefficients (CCC) of 0.95 for , 0.96 for , and 0.73 for the plasma volume using a measured AIF tail. With the literature‐based AIF tail, the CCC was 0.89 for , 0.93 for and 0.78 for .Conclusions: Quantitative DCE‐MRI analysis using the input function tail and a reference tissue yields absolute kinetic parameters with the RRIFT method. This approach was viable in simulation and in vivo for temporal resolutions as low as 30 s.
- 8 August 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (1) , 286-298
Pharmacokinetic modeling of dynamic contrast‐enhanced MRI using a reference region and input function tail
Purpose: Quantitative analysis of dynamic contrast‐enhanced MRI (DCE‐MRI) requires an arterial input function (AIF) which is difficult to measure. We propose the reference region and input function tail (RRIFT) approach which uses a reference tissue and the washout portion of the AIF.Methods: RRIFT was evaluated in simulations with 100 parameter combinations at various temporal resolutions (5‐30 s) and noise levels (σ = 0.01‐0.05 mM). RRIFT was compared against the extended Tofts model (ETM) in 8 studies from patients with glioblastoma multiforme. Two versions of RRIFT were evaluated: one using measured patient‐specific AIF tails, and another assuming a literature‐based AIF tail.Results: RRIFT estimated the transfer constant and interstitial volume with median errors within 20% across all simulations. RRIFT was more accurate and precise than the ETM at temporal resolutions slower than 10 s. The percentage error of had a median and interquartile range of −9 ± 45% with the ETM and −2 ± 17% with RRIFT at a temporal resolution of 30 s under noiseless conditions. RRIFT was in excellent agreement with the ETM in vivo, with concordance correlation coefficients (CCC) of 0.95 for , 0.96 for , and 0.73 for the plasma volume using a measured AIF tail. With the literature‐based AIF tail, the CCC was 0.89 for , 0.93 for and 0.78 for .Conclusions: Quantitative DCE‐MRI analysis using the input function tail and a reference tissue yields absolute kinetic parameters with the RRIFT method. This approach was viable in simulation and in vivo for temporal resolutions as low as 30 s.
- 10 May 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (7) , e3924
An extended reference region model for DCE‐MRI that accounts for plasma volume
The reference region model (RRM) for dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) provides pharmacokinetic parameters without requiring the arterial input function. A limitation of the RRM is that it assumes that the blood plasma volume in the tissue of interest is zero, but this is often not true in highly vascularized tissues, such as some tumours. This study proposes an extended reference region model (ERRM) to account for tissue plasma volume. Furthermore, ERRM was combined with a two‐fit approach to reduce the number of fitting parameters, and this was named the constrained ERRM (CERRM). The accuracy and precision of RRM, ERRM and CERRM were evaluated in simulations covering a range of parameters, noise and temporal resolutions. These models were also compared with the extended Tofts model (ETM) on in vivo glioblastoma multiforme data. In simulations, RRM overestimated Ktrans by over 10% at vp = 0.01 under noiseless conditions. In comparison, ERRM and CERRM were both accurate, with CERRM showing better precision when noise was included. On in vivo data, CERRM provided maps that had the highest agreement with ETM, whilst also being robust at temporal resolutions as poor as 30 s. ERRM can provide pharmacokinetic parameters without an arterial input function in tissues with non‐negligible vp where RRM provides inaccurate estimates. The two‐fit approach, named CERRM, further improves on the accuracy and precision of ERRM.
- 10 May 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (7) , e3924
An extended reference region model for DCE‐MRI that accounts for plasma volume
The reference region model (RRM) for dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) provides pharmacokinetic parameters without requiring the arterial input function. A limitation of the RRM is that it assumes that the blood plasma volume in the tissue of interest is zero, but this is often not true in highly vascularized tissues, such as some tumours. This study proposes an extended reference region model (ERRM) to account for tissue plasma volume. Furthermore, ERRM was combined with a two‐fit approach to reduce the number of fitting parameters, and this was named the constrained ERRM (CERRM). The accuracy and precision of RRM, ERRM and CERRM were evaluated in simulations covering a range of parameters, noise and temporal resolutions. These models were also compared with the extended Tofts model (ETM) on in vivo glioblastoma multiforme data. In simulations, RRM overestimated Ktrans by over 10% at vp = 0.01 under noiseless conditions. In comparison, ERRM and CERRM were both accurate, with CERRM showing better precision when noise was included. On in vivo data, CERRM provided maps that had the highest agreement with ETM, whilst also being robust at temporal resolutions as poor as 30 s. ERRM can provide pharmacokinetic parameters without an arterial input function in tissues with non‐negligible vp where RRM provides inaccurate estimates. The two‐fit approach, named CERRM, further improves on the accuracy and precision of ERRM.