Tissue equivalency of phantom materials for neutron dosimetry in proton therapy
- 5 November 2009
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 36 (12) , 5412-5419
Abstract
Purpose: Previous Monte Carlo and experimental studies involving secondary neutrons in proton therapy have employed a number of phantom materials that are designed to represent human tissue. In this study, the authors determined the suitability of common phantom materials for dosimetry of secondary neutrons, specifically for pediatric and intracranial proton therapy treatments.Methods: This was achieved through comparison of the absorbed dose and dose equivalent from neutrons generated within the phantom materials and various ICRP tissues. The phantom materials chosen for comparison were Lucite, liquid water, solid water, and A150 tissue equivalent plastic. These phantom materials were compared to brain, muscle, and adipose tissues.Results: The magnitude of the doses observed were smaller than those reported in previous experimental and Monte Carlo studies, which incorporated neutrons generated in the treatment head. The results show that for both neutron absorbed dose and dose equivalent, no single phantom material gives agreement with tissue within 5% at all the points considered. Solid water gave the smallest mean variation with the tissues out of field where neutrons are the primary contributor to the total dose.Conclusions: Of the phantom materials considered, solid water shows best agreement with tissues out of field.Keywords
This publication has 27 references indexed in Scilit:
- Out-of-Field Dose Equivalents Delivered by Passively Scattered Therapeutic Proton Beams for Clinically Relevant Field ConfigurationsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Proton Radiotherapy for Childhood Ependymoma: Initial Clinical Outcomes and Dose ComparisonsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancerPhysics in Medicine & Biology, 2008
- Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantomsPhysics in Medicine & Biology, 2008
- Secondary exposure for 73 and 200 MeV proton therapyRadiation Protection Dosimetry, 2006
- Patient neutron dose equivalent exposures outside of the proton therapy treatment fieldRadiation Protection Dosimetry, 2005
- Dose conformation of intensity-modulated stereotactic photon beams, proton beams, and intensity-modulated proton beams for intracranial lesionsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- The Binary CascadeThe European Physical Journal A, 2004
- Advantage of protons compared to conventional X-ray or IMRT in the treatment of a pediatric patient with medulloblastomaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Organ Doses and Dose Equivalents for Neutrons above 20 MeVRadiation Protection Dosimetry, 1997