Leftover Astigmatism: The Missing Link Between Measured and Calculated Posterior Corneal Astigmatism
Authors:
- Michael GogginMGMichael Goggin
- Benjamin R. LaHoodBLBenjamin R. LaHood
- Murilo F. RoggiaMRMurilo F. Roggia
- Tony S. ChenTCTony S. Chen
- Simone BeheregaraySBSimone Beheregaray
- Adrian EstermanAEAdrian Esterman
- 1 September 2022
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 38 (9) , 559-564
Abstract
PURPOSE: To quantify the total eye astigmatism that is not accounted for by measurement of anterior corneal astigmatism and posterior corneal astigmatism and knowledge of intraocular lens (IOL) astigmatism and assess whether it is correlated with candidate sources of or correlates with leftover astigmatism. METHODS: Vector subtraction of anterior corneal, posterior corneal, and IOL astigmatism from total eye astigmatism as represented by spectacle astigmatism to yield a value of “leftover” astigmatism that is neither corneal nor lenticular. This value was derived in a series of eyes following cataract surgery. This novel entity was examined for correlation with candidate sources of or correlates with leftover astigmatism. RESULTS: In 103 pseudophakic eyes with known IOL toricity, mean leftover astigmatism was 0.71 ± 0.43 diopters. This was significantly correlated with against-the-rule anterior corneal astigmatism ( P < .001). CONCLUSIONS: Leftover astigmatism is clinically substantial. Because it is included in IOL cylinder power calculations based on refractive outcome, it may explain why methods of IOL cylinder power calculation using refractive outcome–based adjustments to anterior corneal astigmatism (previously described as adjustments for “posterior corneal astigmatism”) are more successful than adjustment on the basis of measured posterior corneal astigmatism. [ J Refract Surg. 2022;38(9):559–564.]Keywords
This publication has 12 references indexed in Scilit:
- Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometerJournal of Cataract & Refractive Surgery, 2019
- Comparing Total Keratometry Measurement on the IOLMaster 700 With Goggin Nomogram Adjusted Anterior KeratometryJournal of Refractive Surgery, 2018
- Astigmatism induced by intraocular lens tilt evaluated via ray tracingJournal of Cataract & Refractive Surgery, 2018
- Measurement of Posterior Corneal Astigmatism by the IOLMaster 700Journal of Refractive Surgery, 2018
- Assessing the Likely Effect of Posterior Corneal Curvature on Toric IOL Calculation for IOLs of 2.50 D or Greater Cylinder PowerJournal of Refractive Surgery, 2017
- Outcome of adjustment for posterior corneal curvature in toric intraocular lens calculation and selectionJournal of Cataract & Refractive Surgery, 2016
- Distribution of Posterior Corneal Astigmatism According to Axis Orientation of Anterior Corneal AstigmatismPLOS ONE, 2015
- Correcting astigmatism with toric intraocular lenses: Effect of posterior corneal astigmatismJournal of Cataract & Refractive Surgery, 2013
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface MeasurementAmerican Journal of Ophthalmology, 2009