A Laser Doppler Blood Flow Measurement System With a 151.4 dBΩ Gain and 0.05% Nonlinearity for PAD Patients
Open Access
- 13 June 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (14) , 14196-14204
Abstract
This article presents a compact blood flow measurement system exploiting the Doppler effect and photocurrent sensing technique for wearable health monitoring. Specifically, it helps the patients suffering from peripheral artery disease (PAD) to monitor the blood flow continuously without involving a physician or medical expert. The system prototype integrates a laser diode, a photodiode, and an analog front-end (AFE) on a 54 mm $\times64$ mm three-layer PCB using discrete components for proof of concept. The front-end is designed with two output modes providing simultaneous current-to-voltage and current-to-frequency conversion without requiring an external clock source. Moreover, this system does not require optical filters or fibers, dynamic artifacts are therefore significantly reduced. Drawing 33 mA current from a 3.3-V supply, the developed system offers a transimpedance gain of 151.4 dB $\Omega $ for the voltage mode output. For the frequency output, a nonlinearity of 0.05% is achieved.Keywords
Funding Information
- Hamad Bin Khalifa University (HBKU) Innovation (HBKU-INT-IC-IIF-05-01)
This publication has 30 references indexed in Scilit:
- A Hybrid Semi-Digital Transimpedance Amplifier With Noise Cancellation Technique for Nanopore-Based DNA SequencingIEEE Transactions on Biomedical Circuits and Systems, 2015
- Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler FlowmeterSensors, 2015
- A Distributed Amplifier System for Bilayer Lipid Membrane (BLM) Arrays With Noise and Individual Offset CancellationIEEE Transactions on Biomedical Circuits and Systems, 2015
- Laser Doppler Blood Flow Imaging Using a CMOS Imaging Sensor with On-Chip Signal ProcessingSensors, 2013
- CMOS Low Current Measurement System for Biomedical ApplicationsIEEE Transactions on Biomedical Circuits and Systems, 2012
- A normal penile pressure cannot rule out the presence of lesions on the arteries supplying the hypogastric circulation in patients with arterial claudicationVascular Medicine, 2009
- Twente Optical Perfusion Camera: system overview and performance for video rate laser Doppler perfusion imagingOptics Express, 2009
- Wide bandwidth transimpedance amplifier for extremely high sensitivity continuous measurementsReview of Scientific Instruments, 2007
- A Current-Sensitive Front-End Amplifier for Nano-Biosensors with a 2MHz BW2007