Detection of seizure patterns with multichannel amplitude-integrated EEG and the color density spectral array in the adult neurology intensive care unit
Open Access
- 1 September 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (38) , e12514
Abstract
This study's purpose was to determine the sensitivity, false-positive and false-negative of seizure detection in adult intensive care by amplitude-integrated electroencephalography (aEEG) and color density spectral array (CDSA). 30 continuous electroencephalogram (EEG) recordings were randomly performed in 3 digital EEG-recording machines, 3 specialized neurophysiologists participated in this study, underwent 4 hours of training of CDSA and aEEG, marked any epochs suspected to be seizures without access to the raw EEG. The results will be compared and analyzed with continuous EEG reading to consider sensitivity, positive or negative rate. The recordings in this study, comprised 720 hours of EEG containing a total of 435 seizures. The median sensitivity for seizure identification was 80% of CDSA and 81.3% of aEEG, Median false-positive was 4 per 24 hours of CDSA, and 2 per 24 hours of aEEG display, Median false-negative was 4 per 24 hours of CDSA, and 4 per 24 hours of aEEG display. The time spent in identification of seizures by CDSA and aEEG was much time-saving than continuous EEG-reading. In this study, both CDSA and aEEG have a higher sensitivity but lower false-positive or missed rate in the interpretation of seizure identification in adult NICU.Keywords
This publication has 21 references indexed in Scilit:
- Seizure identification in the ICU using quantitative EEG displaysNeurology, 2010
- Continuous Electroencephalogram Monitoring in the Intensive Care UnitAnesthesia & Analgesia, 2009
- Accuracy of Bedside Electroencephalographic Monitoring in Comparison With Simultaneous Continuous Conventional Electroencephalography for Seizure Detection in Term InfantsPediatrics, 2008
- Neonatal seizure detection using multichannel display of envelope trendEpilepsia, 2007
- Postneonatal epilepsy following amplitude-integrated EEG-detected neonatal seizuresPediatric Neurology, 2005
- Non-expert use of the cerebral function monitor for neonatal seizure detectionArchives of Disease in Childhood - Fetal and Neonatal Edition, 2004
- Neonatal seizures: Electroclinical dissociationPediatric Neurology, 1991
- Postnatal Epilepsy After EEG‐Confirmed Neonatal SeizuresEpilepsia, 1991
- Occult Neonatal SeizuresEpilepsia, 1988
- Monitoring cerebral electrical function in the ICUCritical Care Medicine, 1980