Ji Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ji Sun has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Dihui Ma
Department of Neurology, The First Hospital of Jilin University, Changchun, Jilin 130021, China
2 shared publications - Yan Li2 shared publications
- Yudan Lv
The First Hospital of Jilin University
2 shared publications Congzheng Wu
1 shared publicationGuangcheng Zhang
Department of Cardiac Surgery, People's Hospital of Jilin Province, Changchun, Jilin 130021, China
1 shared publicationHepeng Wang
1 shared publication
Latest Publications
- Open Access
- 2 June 2026
- Published by Elsevier in SSRN Electronic Journal
High-quality, high-energy Nd:YAG pulsed laser operating at 100 Hz with multiple wavelengths side-pumping
A water-free, multi-wavelength diode-pumped Nd:YAG laser is demonstrated to yield a maximum output energy of 131 mJ at a pulse repetition frequency of 100 Hz and with pulse width of 9.6 ns. Zemax simulations informed the selection of a 0.8 at.% doping concentration in Nd:YAG crystals, which promoted a near-Gaussian gain profile. Thermal management was optimized through thermal insulation between the crystals and LDAs, combined with thermoelectric coolers (TECs), heat sinks for precise crystal temperature stabilization, and forced-air cooling for the LDAs. An electro-optic Q-switch based on deuterated potassium dihydrogen phosphate (DKDP) enabled stable pulse generation. The system operated reliably at repetition rates of 50-100 Hz, delivering up to 169.5 mJ per pulse at 80 Hz with pulse width ~8.8 ns and 131 mJ at pulse repetition of 100 Hz with pulse width of ~9.6 ns. The energy fluctuations of the RMS are better than 2.2%. Beam quality factors were measured as Mₓ² = 2.61 and Mᵧ² = 3.31. As far as we know, this is the first demonstration using multi-wavelength laser diode arrays as the pump source to achieve >100 mJ single-pulse energy and >10 MW peak power at a pulse repetition of 100 Hz under water-free cooling, while maintaining good beam quality.
- 2 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-quality, high-energy Nd:YAG pulsed laser operating at 100 Hz with multiple wavelengths side-pumping
A water-free, multi-wavelength diode-pumped Nd:YAG laser is demonstrated to yield a maximum output energy of 131 mJ at a pulse repetition frequency of 100 Hz and with pulse width of 9.6 ns. Zemax simulations informed the selection of a 0.8 at.% doping concentration in Nd:YAG crystals, which promoted a near-Gaussian gain profile. Thermal management was optimized through thermal insulation between the crystals and LDAs, combined with thermoelectric coolers (TECs), heat sinks for precise crystal temperature stabilization, and forced-air cooling for the LDAs. An electro-optic Q-switch based on deuterated potassium dihydrogen phosphate (DKDP) enabled stable pulse generation. The system operated reliably at repetition rates of 50-100 Hz, delivering up to 169.5 mJ per pulse at 80 Hz with pulse width ~8.8 ns and 131 mJ at pulse repetition of 100 Hz with pulse width of ~9.6 ns. The energy fluctuations of the RMS are better than 2.2%. Beam quality factors were measured as Mₓ² = 2.61 and Mᵧ² = 3.31. As far as we know, this is the first demonstration using multi-wavelength laser diode arrays as the pump source to achieve >100 mJ single-pulse energy and >10 MW peak power at a pulse repetition of 100 Hz under water-free cooling, while maintaining good beam quality.
- 15 August 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
High energy output generated by double end bonded Nd:YAG crystals
- 15 August 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
High energy output generated by double end bonded Nd:YAG crystals
- Open Access
- 22 April 2020
- Published by Spandidos Publications in Oncology Reports
- Vol. 44 (1) , 156-164
An elongated tract of polyQ in the carboxyl‑terminus of human α1A calcium channel induces cell apoptosis by nuclear translocation
An aberrant elongated tract of glutamine residues (polyQ) in proteins induces multiple diseases treated in the clinic. In our previous study of progressive myoclonic epilepsy (PME), using whole‑exome sequencing, a mutant Cav2.1 protein with an aberrant elongated polyQ tract was identified in PME patients. To investigate the molecular mechanism and cell biology of this aberrant elongated polyQ tract, wild‑type Cav2.1 with 13 polyQ repeats (Cav2.1 wt‑Q13) and mutant‑type Cav2.1 with 26 polyQ repeats (Cav2.1 mt‑Q26) were prepared and introduced into human SH‑SY5Y neuroblastoma cells. Using a WST‑1 assay, it was revealed that Cav2.1 mt‑Q26 markedly suppressed the proliferation of the SH‑SY5Y cells, a result not observed for the Cav2.1 wt‑Q13‑transfected cells. It was also revealed that Cav2.1 mt and its truncated molecules suppressed cell proliferation by inducing apoptosis rather than arresting the cell cycle. Further investigations indicated a nuclear translocation phenomenon associated with the Cav2.1 mt molecules. Mechanistically, it was revealed that the Cav2.1 mt molecules activated the Bcl‑2/Bax, caspase‑3 and poly ADP‑ribose polymerase (PARP) apoptotic pathways. The present study may provide new insights for interpreting the pathogenesis of PME and the relationship among polyQ, CACNA1A gene mutations and PME.
- 22 April 2020
- Published by Spandidos Publications in Oncology Reports
- Vol. 44 (1) , 156-164
Open AccessAn elongated tract of polyQ in the carboxyl‑terminus of human α1A calcium channel induces cell apoptosis by nuclear translocation
An aberrant elongated tract of glutamine residues (polyQ) in proteins induces multiple diseases treated in the clinic. In our previous study of progressive myoclonic epilepsy (PME), using whole‑exome sequencing, a mutant Cav2.1 protein with an aberrant elongated polyQ tract was identified in PME patients. To investigate the molecular mechanism and cell biology of this aberrant elongated polyQ tract, wild‑type Cav2.1 with 13 polyQ repeats (Cav2.1 wt‑Q13) and mutant‑type Cav2.1 with 26 polyQ repeats (Cav2.1 mt‑Q26) were prepared and introduced into human SH‑SY5Y neuroblastoma cells. Using a WST‑1 assay, it was revealed that Cav2.1 mt‑Q26 markedly suppressed the proliferation of the SH‑SY5Y cells, a result not observed for the Cav2.1 wt‑Q13‑transfected cells. It was also revealed that Cav2.1 mt and its truncated molecules suppressed cell proliferation by inducing apoptosis rather than arresting the cell cycle. Further investigations indicated a nuclear translocation phenomenon associated with the Cav2.1 mt molecules. Mechanistically, it was revealed that the Cav2.1 mt molecules activated the Bcl‑2/Bax, caspase‑3 and poly ADP‑ribose polymerase (PARP) apoptotic pathways. The present study may provide new insights for interpreting the pathogenesis of PME and the relationship among polyQ, CACNA1A gene mutations and PME.
- Open Access
- 1 September 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (38) , e12514
Detection of seizure patterns with multichannel amplitude-integrated EEG and the color density spectral array in the adult neurology intensive care unit
This study's purpose was to determine the sensitivity, false-positive and false-negative of seizure detection in adult intensive care by amplitude-integrated electroencephalography (aEEG) and color density spectral array (CDSA). 30 continuous electroencephalogram (EEG) recordings were randomly performed in 3 digital EEG-recording machines, 3 specialized neurophysiologists participated in this study, underwent 4 hours of training of CDSA and aEEG, marked any epochs suspected to be seizures without access to the raw EEG. The results will be compared and analyzed with continuous EEG reading to consider sensitivity, positive or negative rate. The recordings in this study, comprised 720 hours of EEG containing a total of 435 seizures. The median sensitivity for seizure identification was 80% of CDSA and 81.3% of aEEG, Median false-positive was 4 per 24 hours of CDSA, and 2 per 24 hours of aEEG display, Median false-negative was 4 per 24 hours of CDSA, and 4 per 24 hours of aEEG display. The time spent in identification of seizures by CDSA and aEEG was much time-saving than continuous EEG-reading. In this study, both CDSA and aEEG have a higher sensitivity but lower false-positive or missed rate in the interpretation of seizure identification in adult NICU.
- 1 September 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (38) , e12514
Open AccessDetection of seizure patterns with multichannel amplitude-integrated EEG and the color density spectral array in the adult neurology intensive care unit
This study's purpose was to determine the sensitivity, false-positive and false-negative of seizure detection in adult intensive care by amplitude-integrated electroencephalography (aEEG) and color density spectral array (CDSA). 30 continuous electroencephalogram (EEG) recordings were randomly performed in 3 digital EEG-recording machines, 3 specialized neurophysiologists participated in this study, underwent 4 hours of training of CDSA and aEEG, marked any epochs suspected to be seizures without access to the raw EEG. The results will be compared and analyzed with continuous EEG reading to consider sensitivity, positive or negative rate. The recordings in this study, comprised 720 hours of EEG containing a total of 435 seizures. The median sensitivity for seizure identification was 80% of CDSA and 81.3% of aEEG, Median false-positive was 4 per 24 hours of CDSA, and 2 per 24 hours of aEEG display, Median false-negative was 4 per 24 hours of CDSA, and 4 per 24 hours of aEEG display. The time spent in identification of seizures by CDSA and aEEG was much time-saving than continuous EEG-reading. In this study, both CDSA and aEEG have a higher sensitivity but lower false-positive or missed rate in the interpretation of seizure identification in adult NICU.
- 1 August 2014
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 49 (8) , 1335-1340
Surgical treatment and outcomes of pentalogy of Cantrell in eight patients
- 1 August 2014
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 49 (8) , 1335-1340
Surgical treatment and outcomes of pentalogy of Cantrell in eight patients