Dosimetric properties of Gafchromic® EBT films in medical carbon ion beams
Authors:
- Mária MartišíkováMMMária Martišíková
- Oliver JäkelOJOliver Jäkel
- 31 August 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (18) , 5557-5567
Abstract
High spatial resolution is desired for dosimetrical verification of patient plans for radiotherapy treatments employing scanned ion beams. This is provided by Gafchromic EBT film, the ancestor of currently available EBT2 films. In this contribution, dosimetric properties of EBT films were investigated. Measurements of depth response were performed for monoenergetic fields (250 MeV/u) for different ion fluences as well as for an energy-modulated spread-out Bragg peak of 5 x 5 x 5 cm(3) in 10 cm depth. The films were positioned perpendicular to the incoming carbon ion beams. The observed quenching of the response relative to the same dose of photons was quantified by the relative efficiency. In monenenergetic beams, a relative efficiency of about 0.73 was found in the plateau, 0.4 in the peak and 0.55 in the tail region. No dependence of the relative efficiency on the ion fluence was observed well beyond the clinically used levels. This gives a constant peak to plateau ratio, which is about 1.8 times lower than that for the delivered dose. In the spread-out Bragg peak, the relative efficiency was found to decrease from 0.64 to 0.54 toward the distal end. Thus when aiming for a prediction of the film response in mixed ion beams, the efficiency of the film has to be parametrized as a function of the ion type and energy over the whole ion spectrum. In addition, the relative water-equivalent range of EBT films was measured here to be 1.291 +/- 0.015.Keywords
This publication has 27 references indexed in Scilit:
- Technical Note: Homogeneity of Gafchromic®EBT2 filmMedical Physics, 2010
- From the limits of the classical model of sensitometric curves to a realistic model based on the percolation theory for GafChromic™ EBT filmsMedical Physics, 2009
- Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurancePhysics in Medicine & Biology, 2007
- Clinical use of EBT model Gafchromic™ film in radiotherapyMedical Physics, 2006
- Absorption spectra variations of EBT radiochromic film from radiation exposurePhysics in Medicine & Biology, 2005
- Precise radiochromic film dosimetry using a flat-bed document scannerMedical Physics, 2005
- Relation between carbon ion ranges and x‐ray CT numbersMedical Physics, 2001
- Quality management of medical physics issues at the German heavy ion therapy projectMedical Physics, 2000
- Energy loss of 70 MeV protons in organic polymersMedical Physics, 1993
- Experimental and Calculated Response of a Radiochromic Dye Film Dosimeter to High-LET RadiationsRadiation Research, 1984