Abstract
In this work, an FPGA-based plain delay line TDC is presented, together with a theoretical model on its timing properties. The TDC features an automated calibration system implemented in the on-chip processor of a SoC-FPGA, uses a low amount of FPGA resources and is therefore suitable for applications requiring a high number of channels such as Time-of-Flight Positron Emission Tomography. We first investigated the importance of calibration and validated the theoretical model on the TDC timing properties. Finally, the device has been embodied into a two channel Positron Emission Tomography acquisition system and tested. We found the calibration essential to obtain a good time resolution (38 ps FWHM in comparison with a 78 ps FWHM obtained with the uncalibrated device). The model we developed is able to predict the TDC timing properties. They are shown to be related to the fundamental parameters of the used FPGA technology. In particular, the best achievable time resolution of this specific architecture (plain tapped delay line on FPGA) is set to about 30 ps by the sum of the setup and hold times of the registers in the FPGA. The timing resolution of the two-channel setup is about 118 ps.Keywords
Funding Information
- Seventh Framework Programme (602621-Trimage)
- Ministerio de Economía y Competitividad (TEC2015-66002-R, MDM-2014-0369)
This publication has 15 references indexed in Scilit:
- A comparative study of the time performance between NINO and FlexToT ASICsJournal of Instrumentation, 2017
- The TRIMAGE PET Data Acquisition System: Initial ResultsIEEE Transactions on Radiation and Plasma Medical Sciences, 2016
- Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with CaPhysics in Medicine & Biology, 2015
- Randoms and TOF gain revisitedPhysics in Medicine & Biology, 2015
- The Design of a 16-Channel 15 ps TDC Implemented in a 65 nm FPGAIEEE Transactions on Nuclear Science, 2013
- Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: an experimental and theoretical analysisJournal of Instrumentation, 2013
- Novel detector technology for clinical PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Wallace tree encoding in folding and interpolation ADCs2003
- A high-resolution CMOS time-to-digital converter utilizing a Vernier delay lineIEEE Journal of Solid-State Circuits, 2000
- Interpolating time counter with 100 ps resolution on a single FPGA deviceIEEE Transactions on Instrumentation and Measurement, 2000