Femtosecond Laser Microfabricated Optofluidic Mach–Zehnder Interferometer for Refractive Index Sensing
- 20 September 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 54 (6) , 1-7
Abstract
An approach for refractive index (RI) sensing is proposed using a waveguide-based optofluidic Mach-Zehnder interferometer (MZI). In this optofluidic MZI, the sensing arm is an epoxy-based negative photoresist (SU-8) core fabricated with femtosecond laser-induced two-photon polymerization technique, while the reference arm is the glass substrate. By integrating the SU-8 core with a microchannel, a RI sensor is realized with which the RI of sodium chloride (NaCl) solution has been measured. Effects of the chip length, microchannel length, and core size on the sensitivity of RI measurement have been revealed, indicating a shorter chip length, longer microchannel, and smaller core size can achieve a higher sensitivity, which is advantageous for sensing applications.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- Canada Research Chairs
- Canada Foundation for Innovation
- Province of Newfoundland and Labrador
- Memorial University of Newfoundland
This publication has 28 references indexed in Scilit:
- Optofluidic waveguide as a transformation optics device for lightwave bending and manipulationNature Communications, 2012
- Integrated polymer-based Mach-Zehnder interferometer label-free streptavidin biosensor compatible with injection moldingBiosensors and Bioelectronics, 2011
- Optofluidic waveguides for reconfigurable photonic systemsOptics Express, 2011
- Fiber in-line Mach-Zehnder interferometer fabricated by femtosecond laser micromachining for refractive index measurement with high sensitivityJournal of the Optical Society of America B, 2010
- Integrated optofluidics: A new river of lightNature Photonics, 2007
- Developing optofluidic technology through the fusion of microfluidics and opticsNature, 2006
- The origins and the future of microfluidicsNature, 2006
- A Mach-Zehnder interferometer based on silicon oxides for biosensor applicationsAnalytica Chimica Acta, 2006
- Optical biosensor microsystems based on the integration of highly sensitive Mach–Zehnder interferometer devicesJournal of Optics A: Pure and Applied Optics, 2006
- Integrated optical Mach-Zehnder interferometers as simazine immunoprobesSensors and Actuators B: Chemical, 1997