Qiying Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiying Chen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Daiying Zhang
Department of Physics and Physical Oceanography, Memorial University of Newfoundland, St. John's, Newfoundland, Canada
4 shared publications Liqiu Men
Department of Physics and Physical Oceanography, Memorial University of Newfoundland, St. John's, Newfoundland, Canada
4 shared publications- Liqiu Men
Department of Physics and Physical Oceanography, Memorial University of Newfoundland, St. John's, Newfoundland and Labrador Canada
4 shared publications D. Zhang
Department of Physics and Physical Oceanography Memorial University of Newfoundland St. John's Newfoundland A1B 3X7 Canada
2 shared publicationsL. Men
Department of Physics and Physical Oceanography Memorial University of Newfoundland St. John's Newfoundland A1B 3X7 Canada
2 shared publicationsPing Lu
Department of Physics and Physical Oceanography, Memorial University of Newfoundland, St. John's, Newfoundland A1B 3X7, Canada
2 shared publications
Latest Publications
- 12 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 27 (4) , 1-7
Waveguide Mach-Zehnder Interferometer for Temperature and Concentration Sensing
Mach-Zehnder interferometer (MZI) based on optical waveguide is proposed and demonstrated, in which a waveguide core with a core expander and a collector is inscribed in a photoresist SU-8 film by ultrafast laser-induced two-photon polymerization (TPP) technique, whereas the cladding of the waveguide is fabricated by the standard photolithographic technique. Interference occurs in this MZI when the light is scattered into the cladding by the core expander and then collected by the core collector, in which the roles of the core expander and the collector are investigated in details. By integrating with a microchannel, a waveguide-based optofluidic MZI sensor is realized, which exhibits a redshift at a sensitivity of 0.618 nm/°C with the increase of temperature, and blueshifts at sensitivities of -0.102 nm/wt% and -0.092 nm/°Bx for concentration measurement of sodium chloride and sucrose solutions, respectively. Experimental results demonstrate the effectiveness of this sensor for temperature and concentration measurement, manifesting its promising potential for biomedical, chemical, and environmental applications.
- 12 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 27 (4) , 1-7
Waveguide Mach-Zehnder Interferometer for Temperature and Concentration Sensing
Mach-Zehnder interferometer (MZI) based on optical waveguide is proposed and demonstrated, in which a waveguide core with a core expander and a collector is inscribed in a photoresist SU-8 film by ultrafast laser-induced two-photon polymerization (TPP) technique, whereas the cladding of the waveguide is fabricated by the standard photolithographic technique. Interference occurs in this MZI when the light is scattered into the cladding by the core expander and then collected by the core collector, in which the roles of the core expander and the collector are investigated in details. By integrating with a microchannel, a waveguide-based optofluidic MZI sensor is realized, which exhibits a redshift at a sensitivity of 0.618 nm/°C with the increase of temperature, and blueshifts at sensitivities of -0.102 nm/wt% and -0.092 nm/°Bx for concentration measurement of sodium chloride and sucrose solutions, respectively. Experimental results demonstrate the effectiveness of this sensor for temperature and concentration measurement, manifesting its promising potential for biomedical, chemical, and environmental applications.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-7
Femtosecond Laser Microfabricated Microfilters for Particle–Liquid Separation in a Microfluidic Chip
A novel cross-flow based particle sorter is proposed and demonstrated in this study. The filtration structures consist of two groups of micropillars which are fabricated with photoresist material SU-8 using femtosecond laser induced two-photon polymerization (TPP) technique. Particles can be separated according to the slit sizes of the micropillars. The distributions of flow velocity and particle trajectories in filters of different lengths are simulated with the COMSOL software. The particle sorting efficiencies are calculated and compared. The microfluidic sorter chip is tested with a fluid consisting of mixed microbeads with diameters of 10 μm and 5 μm. The performance of the sorter developed in this study demonstrates its effectiveness and efficiency in sorting particles in a fluid. Furthermore, the femtosecond laser induced TPP microfabrication technique enables the fabrication of customized microstructures with a high degree of integration and low fabrication cost, promising for various biological, chemical, and environmental applications.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 25 (1) , 1-7
Femtosecond Laser Microfabricated Microfilters for Particle–Liquid Separation in a Microfluidic Chip
A novel cross-flow based particle sorter is proposed and demonstrated in this study. The filtration structures consist of two groups of micropillars which are fabricated with photoresist material SU-8 using femtosecond laser induced two-photon polymerization (TPP) technique. Particles can be separated according to the slit sizes of the micropillars. The distributions of flow velocity and particle trajectories in filters of different lengths are simulated with the COMSOL software. The particle sorting efficiencies are calculated and compared. The microfluidic sorter chip is tested with a fluid consisting of mixed microbeads with diameters of 10 μm and 5 μm. The performance of the sorter developed in this study demonstrates its effectiveness and efficiency in sorting particles in a fluid. Furthermore, the femtosecond laser induced TPP microfabrication technique enables the fabrication of customized microstructures with a high degree of integration and low fabrication cost, promising for various biological, chemical, and environmental applications.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 54 (6) , 1-7
Femtosecond Laser Microfabricated Optofluidic Mach–Zehnder Interferometer for Refractive Index Sensing
An approach for refractive index (RI) sensing is proposed using a waveguide-based optofluidic Mach-Zehnder interferometer (MZI). In this optofluidic MZI, the sensing arm is an epoxy-based negative photoresist (SU-8) core fabricated with femtosecond laser-induced two-photon polymerization technique, while the reference arm is the glass substrate. By integrating the SU-8 core with a microchannel, a RI sensor is realized with which the RI of sodium chloride (NaCl) solution has been measured. Effects of the chip length, microchannel length, and core size on the sensitivity of RI measurement have been revealed, indicating a shorter chip length, longer microchannel, and smaller core size can achieve a higher sensitivity, which is advantageous for sensing applications.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 54 (6) , 1-7
Femtosecond Laser Microfabricated Optofluidic Mach–Zehnder Interferometer for Refractive Index Sensing
An approach for refractive index (RI) sensing is proposed using a waveguide-based optofluidic Mach-Zehnder interferometer (MZI). In this optofluidic MZI, the sensing arm is an epoxy-based negative photoresist (SU-8) core fabricated with femtosecond laser-induced two-photon polymerization technique, while the reference arm is the glass substrate. By integrating the SU-8 core with a microchannel, a RI sensor is realized with which the RI of sodium chloride (NaCl) solution has been measured. Effects of the chip length, microchannel length, and core size on the sensitivity of RI measurement have been revealed, indicating a shorter chip length, longer microchannel, and smaller core size can achieve a higher sensitivity, which is advantageous for sensing applications.
- Open Access
- 1 September 2018
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 2 (9) , 095016
Femtosecond laser fabricated polymeric grating for spectral tuning
By taking advantages of the two-photon polymerization induced by femtosecond laser and the versatility of the femtosecond laser microfabrication, we demonstrate a femtosecond laser microfabricated polymeric grating for spectral tuning, in which gratings of different thicknesses achieve gradual tuning of a white incident light into output lights of different colors ranging from cyan to red, which is in good agreement with the simulation. Through the selection of different grating parameters, the technique developed in this study offers the possibility to tailor the performance of the grating to achieve specific grating efficiency or complete extinction at specific wavelengths, which is promising for measurements and applications in spectroscopy, sensing, integrated optical systems, and biomedicine.
- 1 September 2018
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 2 (9) , 095016
Open AccessFemtosecond laser fabricated polymeric grating for spectral tuning
By taking advantages of the two-photon polymerization induced by femtosecond laser and the versatility of the femtosecond laser microfabrication, we demonstrate a femtosecond laser microfabricated polymeric grating for spectral tuning, in which gratings of different thicknesses achieve gradual tuning of a white incident light into output lights of different colors ranging from cyan to red, which is in good agreement with the simulation. Through the selection of different grating parameters, the technique developed in this study offers the possibility to tailor the performance of the grating to achieve specific grating efficiency or complete extinction at specific wavelengths, which is promising for measurements and applications in spectroscopy, sensing, integrated optical systems, and biomedicine.
- Open Access
- 1 July 2018
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 54 (14) , 888-890
Femtosecond laser fabricated polymer microring resonator for sensing applications
A microring resonator realised by femtosecond laser two‐photon photopolymerisation in an epoxy‐based negative photoresist (SU‐8) is proposed and demonstrated, which is further proved to be capable of temperature and refractive index sensing by monitoring the shift of the resonance wavelength of the interferometric pattern. The experimental results indicate refractive index sensitivity of 12.50 nm/refractive index unit (redshift) and temperature sensitivity of −9.51 × 10 −2 nm/ o C (blueshift), respectively.
- 1 July 2018
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 54 (14) , 888-890
Open AccessFemtosecond laser fabricated polymer microring resonator for sensing applications
A microring resonator realised by femtosecond laser two‐photon photopolymerisation in an epoxy‐based negative photoresist (SU‐8) is proposed and demonstrated, which is further proved to be capable of temperature and refractive index sensing by monitoring the shift of the resonance wavelength of the interferometric pattern. The experimental results indicate refractive index sensitivity of 12.50 nm/refractive index unit (redshift) and temperature sensitivity of −9.51 × 10 −2 nm/ o C (blueshift), respectively.
- 15 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 30 (4) , 395-398
Femtosecond Laser Microfabricated Optofluidic Grating Refractometer
A novel femtosecond laser microfabricated optofluidic grating is proposed and demonstrated in this letter, which realizes the measurement of refractive index of liquid. The diffraction grating is fabricated with an epoxy-based negative photoresist (SU-8) on glass substrate by femtosecond laser-induced two-photon polymerization and bonded with a polydimethylsiloxane microchannel, for which the transmission spectrum can be modulated by changing the refractive index of the liquid flowing in the microchannel. Experimental observation on the shift of the transmission peak wavelength indicates that the sensitivity of the diffraction grating is higher for a lower-order mode or a thicker grating, i.e., blue-shifted peak wavelength with a magnitude of$3.586\times 10^{3}\,\,\mu \text{m}$ per refractive index unit for the second-order mode of the grating with a thickness of 3.60$\mu \text{m}$ .- 15 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 30 (4) , 395-398
Femtosecond Laser Microfabricated Optofluidic Grating Refractometer
A novel femtosecond laser microfabricated optofluidic grating is proposed and demonstrated in this letter, which realizes the measurement of refractive index of liquid. The diffraction grating is fabricated with an epoxy-based negative photoresist (SU-8) on glass substrate by femtosecond laser-induced two-photon polymerization and bonded with a polydimethylsiloxane microchannel, for which the transmission spectrum can be modulated by changing the refractive index of the liquid flowing in the microchannel. Experimental observation on the shift of the transmission peak wavelength indicates that the sensitivity of the diffraction grating is higher for a lower-order mode or a thicker grating, i.e., blue-shifted peak wavelength with a magnitude of$3.586\times 10^{3}\,\,\mu \text{m}$ per refractive index unit for the second-order mode of the grating with a thickness of 3.60$\mu \text{m}$ .- Open Access
- 1 January 2016
- Published by International Society for Environmental Information Science (ISEIS) in Journal of Environmental Informatics
- Vol. 28 (2) , 120-125
Ocean Observation with Opto-Microfluidic Devices
Ocean Observation with Opto-Microfluidic Devices
- 1 January 2016
- Published by International Society for Environmental Information Science (ISEIS) in Journal of Environmental Informatics
- Vol. 28 (2) , 120-125
Open AccessOcean Observation with Opto-Microfluidic Devices
Ocean Observation with Opto-Microfluidic Devices
- Open Access
Microfabrication and Applications of Opto-Microfluidic Sensors
A review of research activities on opto-microfluidic sensors carried out by the research groups in Canada is presented. After a brief introduction of this exciting research field, detailed discussion is focused on different techniques for the fabrication of opto-microfluidic sensors, and various applications of these devices for bioanalysis, chemical detection, and optical measurement. Our current research on femtosecond laser microfabrication of optofluidic devices is introduced and some experimental results are elaborated. The research on opto-microfluidics provides highly sensitive opto-microfluidic sensors for practical applications with significant advantages of portability, efficiency, sensitivity, versatility, and low cost.
Open AccessMicrofabrication and Applications of Opto-Microfluidic Sensors
A review of research activities on opto-microfluidic sensors carried out by the research groups in Canada is presented. After a brief introduction of this exciting research field, detailed discussion is focused on different techniques for the fabrication of opto-microfluidic sensors, and various applications of these devices for bioanalysis, chemical detection, and optical measurement. Our current research on femtosecond laser microfabrication of optofluidic devices is introduced and some experimental results are elaborated. The research on opto-microfluidics provides highly sensitive opto-microfluidic sensors for practical applications with significant advantages of portability, efficiency, sensitivity, versatility, and low cost.
- 13 January 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (2) , 268-270
Femtosecond laser microfabricated fiber Mach–Zehnder interferometer for sensing applications
We demonstrate a femtosecond laser microfabricated fiber Mach–Zehnder interferometer and reveal the dependences of the sensitivities of different environmental parameters on the specifications of the interferometer. A 30-mm-long fiber interferometer at a wavelength of exhibits a temperature sensitivity of , axial strain sensitivity of , and refractive index sensitivity of , respectively. In addition to dependence on interferometer length, the sensitivities are also strongly dependent on the operation wavelength of the selected interference order. When the operation wavelength is selected at , the sensitivities are , , and , respectively.- 13 January 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (2) , 268-270
Femtosecond laser microfabricated fiber Mach–Zehnder interferometer for sensing applications
We demonstrate a femtosecond laser microfabricated fiber Mach–Zehnder interferometer and reveal the dependences of the sensitivities of different environmental parameters on the specifications of the interferometer. A 30-mm-long fiber interferometer at a wavelength of exhibits a temperature sensitivity of , axial strain sensitivity of , and refractive index sensitivity of , respectively. In addition to dependence on interferometer length, the sensitivities are also strongly dependent on the operation wavelength of the selected interference order. When the operation wavelength is selected at , the sensitivities are , , and , respectively.- 26 September 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6757
Fiber-optic sensor probing with a thermoreversible film
Thermoreversible compounds have been investigated for applications as a transducer in a fiber-optic temperature sensor utilizing a 2×2 fiber optic coupler. The dependence of the reflected optical power on the temperature has been studied. The reflected optical power at 632.8 nm indicated a monotonous change in the temperature range of observation, corresponding to 2.05dB increase in the optical power when the temperature increased from 20°C to 134°C. The temperature dependence of the optical properties was found to be reversible, which indicates that the temperature transducer is reversible as well.
- 26 September 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6757
Fiber-optic sensor probing with a thermoreversible film
Thermoreversible compounds have been investigated for applications as a transducer in a fiber-optic temperature sensor utilizing a 2×2 fiber optic coupler. The dependence of the reflected optical power on the temperature has been studied. The reflected optical power at 632.8 nm indicated a monotonous change in the temperature range of observation, corresponding to 2.05dB increase in the optical power when the temperature increased from 20°C to 134°C. The temperature dependence of the optical properties was found to be reversible, which indicates that the temperature transducer is reversible as well.