Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
Authors:
- 2 November 2018
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Network Open
- Vol. 1 (7) , e185474
Abstract
Can in silico imaging trials play a role in the evaluation of new medical imaging systems? This diagnostic study used computer-simulated imaging of 2986 synthetic image–based virtual patients to compare digital mammography and digital breast tomosynthesis and found an improved lesion detection performance favoring tomosynthesis for all breast sizes and lesion types. The increased performance for tomosynthesis was consistent with results from a comparative trial using human patients and radiologists. The study’s findings suggest that in silico imaging trials and imaging system computer simulation tools can in some cases be considered viable sources of evidence for the regulatory evaluation of imaging devices. Expensive and lengthy clinical trials can delay regulatory evaluation of innovative technologies, affecting patient access to high-quality medical products. Simulation is increasingly being used in product development but rarely in regulatory applications. To conduct a computer-simulated imaging trial evaluating digital breast tomosynthesis (DBT) as a replacement for digital mammography (DM) and to compare the results with a comparative clinical trial. The simulated Virtual Imaging Clinical Trial for Regulatory Evaluation (VICTRE) trial was designed to replicate a clinical trial that used human patients and radiologists. Images obtained with in silico versions of DM and DBT systems via fast Monte Carlo x-ray transport were interpreted by a computational reader detecting the presence of lesions. A total of 2986 synthetic image–based virtual patients with breast sizes and radiographic densities representative of a screening population and compressed thicknesses from 3.5 to 6 cm were generated using an analytic approach in which anatomical structures are randomly created within a predefined breast volume and compressed in the craniocaudal orientation. A positive cohort contained a digitally inserted microcalcification cluster or spiculated mass. The trial end point was the difference in area under the receiver operating characteristic curve between modalities for lesion detection. The trial was sized for an SE of 0.01 in the change in area under the curve (AUC), half the uncertainty in the comparative clinical trial. In this trial, computational readers analyzed 31 055 DM and 27 960 DBT cases from 2986 virtual patients with the following Breast Imaging Reporting and Data System densities: 286 (9.6%) extremely dense, 1200 (40.2%) heterogeneously dense, 1200 (40.2%) scattered fibroglandular densities, and 300 (10.0%) almost entirely fat. The mean (SE) change in AUC was 0.0587 (0.0062) (P < .001) in favor of DBT. The change in AUC was larger for masses (mean [SE], 0.0903 [0.008]) than for calcifications (mean [SE], 0.0268 [0.004]), which was consistent with the findings of the comparative trial (mean [SE], 0.065 [0.017] for masses and −0.047 [0.032] for calcifications). The results of the simulated VICTRE trial are consistent with the performance seen in the comparative trial. While further research is needed to assess the generalizability of these findings, in silico imaging trials represent a viable source of regulatory evidence for imaging devices.Keywords
This publication has 29 references indexed in Scilit:
- Channelized Hotelling observers for the assessment of volumetric imaging data setsJournal of the Optical Society of America A, 2011
- Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unitMedical Physics, 2009
- Experimental validation of a three‐dimensional linear system model for breast tomosynthesisMedical Physics, 2008
- A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone‐beam CT breast imagingMedical Physics, 2006
- One-Shot Estimate of MRMC Variance: AUCAcademic Radiology, 2006
- Validating the use of channels to estimate the ideal linear observerJournal of the Optical Society of America A, 2003
- Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variabilityJournal of the Optical Society of America A, 2001
- Addition of a channel mechanism to the ideal-observer modelJournal of the Optical Society of America A, 1987
- X-ray transmission formula for antiscatter gridsPhysics in Medicine & Biology, 1983
- Efficiency of Human Visual Signal DiscriminationScience, 1981