Early vascular healing after titanium–nitride–oxide-coated stent versus platinum–chromium everolimus-eluting stent implantation in patients with acute coronary syndrome
- 13 April 2016
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (7) , 1031-1039
Abstract
Data on early vascular healing response of novel stent designs are scarce. In this randomized prospective trial, we sought to compare early neointimal coverage of cobalt–chromium-based titanium–nitride–oxide-coated bioactive stents (CoCr-BAS) versus platinum–chromium everolimus-eluting stents (PtCr-EES) at 2-month follow-up in patients with acute coronary syndrome (ACS). Forty patients with ACS were randomized to receive either CoCr-BAS (n = 19) or PtCr-EES (n = 21). Neointimal strut coverage and strut apposition were examined by optical coherence tomography; and coronary flow reserve (CFR), fractional flow reserve (FFR) and index of microcirculatory resistance (IMR) were assessed using a coronary pressure wire at 2 months. Two patients in the PtCr-EES underwent OCT out of the time frame of the study, and were excluded from analysis. At 63 ± 8 days, 302 cross-sections (3412 struts) were analysed in the CoCr-BAS group, and 324 cross-sections (3460 struts) in the PtCr-EES group. Median [IQR] neointimal thickness was 203 [108] µm and 42.2 [41] µm for CoCr-BAS and PtCr-EES, respectively (p < 0.001). Median [IQR] percentage of uncovered struts was 1.2 [2.8] % versus 11.3 [17.7] %, respectively (p < 0.001). Flow measurements were comparable between the two groups (p > 0.05 for all). CoCr-BAS showed earlier and more adequate neointimal coverage of struts at 2 months, compared with PtCr-EES, but with more neointimal hyperplasia. Functional healing as assessed by CFR, FFR, and IMR was similar between the two stent arms.Keywords
Funding Information
- Finnish Cardiac Society
- Sydäntutkimussäätiö
This publication has 34 references indexed in Scilit:
- Randomized comparison between 3-month Cre8 DES vs. 1-month Vision/Multilink8 BMS neointimal coverage assessed by OCT evaluation: The DEMONSTRATE studyInternational Journal of Cardiology, 2014
- Lack of association between dual antiplatelet therapy use and stent thrombosis between 1 and 12 months following resolute zotarolimus-eluting stent implantationEuropean Heart Journal, 2014
- Dipyridamole coronary flow reserve stratifies prognosis in acute coronary syndrome patients without left anterior descending diseaseEuropean Heart Journal - Cardiovascular Imaging, 2013
- Comparison of Early Strut Coverage Between Zotarolimus- and Everolimus-Eluting Stents Using Optical Coherence TomographyThe American Journal of Cardiology, 2013
- Short- and Long-Term Outcomes With Drug-Eluting and Bare-Metal Coronary StentsCirculation, 2012
- Impact of different stent alloys on human vascular response to everolimus‐eluting stent: An optical coherence tomography study: The OCTEVERESTCatheterization and Cardiovascular Interventions, 2012
- ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: The Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC)European Heart Journal, 2011
- A Prospective, Randomized Evaluation of a Novel Everolimus-Eluting Coronary StentJACC, 2011
- Five-Year Clinical Outcome of Titanium-Nitride-Oxide-Coated Bioactive Stent Implantation in a Real-World Population: A Comparison with Paclitaxel-eluting Stents: The PORI RegistryJournal of Interventional Cardiology, 2010
- Pathology of Drug-Eluting Stents in HumansJACC, 2006