Measuring femoral lesions despite CT metal artefacts: a cadaveric study
Open Access
- 6 July 2011
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 41 (5) , 547-555
Abstract
Objective Computed tomography is the modality of choice for measuring osteolysis but suffers from metal-induced artefacts obscuring periprosthetic tissues. Previous papers on metal artefact reduction (MAR) show qualitative improvements, but their algorithms have not found acceptance for clinical applications. We investigated to what extent metal artefacts interfere with the segmentation of lesions adjacent to a metal femoral implant and whether metal artefact reduction improves the manual segmentation of such lesions. Materials and methods We manually created 27 periprosthetic lesions in 10 human cadaver femora. We filled the lesions with a fibrotic interface tissue substitute. Each femur was fitted with a polished tapered cobalt-chrome prosthesis and imaged twice—once with the metal, and once with a substitute resin prosthesis inserted. Metal-affected CTs were processed using standard back-projection as well as projection interpolation (PI) MAR. Two experienced users segmented all lesions and compared segmentation accuracy. Results We achieved accurate delineation of periprosthetic lesions in the metal-free images. The presence of a metal implant led us to underestimate lesion volume and introduced geometrical errors in segmentation boundaries. Although PI MAR reduced streak artefacts, it led to greater underestimation of lesion volume and greater geometrical errors than without its application. Conclusion CT metal artefacts impair image segmentation. PI MAR can improve subjective image appearance but causes loss of detail and lower image contrast adjacent to prostheses. Our experiments showed that PI MAR is counterproductive for manual segmentation of periprosthetic lesions and should be used with care.Keywords
This publication has 30 references indexed in Scilit:
- Interactive segmentation framework of the Medical Imaging Interaction ToolkitComputer Methods and Programs in Biomedicine, 2009
- Hippocampus segmentation in MR images using atlas registration, voxel classification, and graph cutsNeuroImage, 2008
- CT and MRI of hip arthroplastyClinical Radiology, 2007
- Comparison of CT, MRI, and Radiographs in Assessing Pelvic OsteolysisClinical Orthopaedics and Related Research, 2005
- Magnetic resonance imaging in the evaluation of periprosthetic acetabular osteolysis: A cadaveric studyJournal of Orthopaedic Research, 2005
- Osteolysis—basic science, incidence and diagnosisCurrent Orthopaedics, 2004
- A New Algorithm for Metal Artifact Reduction in Computed TomographyInvestigative Radiology, 2003
- Use of volumetric computerized tomography as a primary outcome measure to evaluate drug efficacy in the prevention of peri‐prosthetic osteolysis: A 1‐year clinical pilot of etanercept vs. placeboJournal of Orthopaedic Research, 2003
- Measurement of Bone Defects Adjacent to Acetabular Components of Hip ReplacementClinical Orthopaedics and Related Research, 2003
- An iterative maximum-likelihood polychromatic algorithm for CTIEEE Transactions on Medical Imaging, 2001