Correlation between driveline features and driveline infection in left ventricular assist device selection
- 22 July 2016
- journal article
- research article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (1) , 34-41
Abstract
Although the survival rate for left ventricular assist device (LVAD) therapy has improved, device-related complications are an unpredictable threat to the patient’s quality of life. We focused on driveline infection, and aimed to determine whether specific features of drivelines affect the frequency of infection. We enrolled patients who underwent LVAD implantation and were followed-up at our institute between 2007 and 2015. We counted the occurrences of driveline infection requiring any antibiotic therapy over a 2-year study period. Furthermore, we experimentally measured and compared the outer diameters and stiffness of three devices. Of all, 72 patients received an LVAD during the enrollment period. LVADs were HeartMate II (n = 32), EVAHEART (n = 22), and DuraHeart (n = 18). The outer diameters and stiffness were measured in five of each device. HeartMate II group had the highest driveline infection-free rate among all three devices during the study period (p = 0.042). The driveline of the HeartMate II LVAD had a significantly smaller outer diameter and lower stiffness than that of the other two devices (p < 0.05 for both). In conclusion, device-specific driveline features may affect the development of driveline infection during LVAD therapy.Keywords
This publication has 22 references indexed in Scilit:
- Left ventricular assist device driveline infections: recent advances and future goals2015
- Special Treatment and Wound Care of the Driveline Exit Site after Left Ventricular Assist Device ImplantationThe Thoracic and Cardiovascular Surgeon, 2015
- Readmissions After Continuous Flow Left Ventricular Assist Device ImplantationASAIO Journal, 2015
- Advantage of Pulsatility in Left Ventricular Reverse Remodeling and Aortic Insufficiency Prevention During Left Ventricular Assist Device TreatmentCirculation Journal, 2015
- A Review of Infections in Patients with Left Ventricular Assist Devices: Prevention, Diagnosis and ManagementMethodist DeBakey Cardiovascular Journal, 2015
- Technique for minimizing and treating driveline infections2014
- Post-approval study of a highly pulsed, low-shear-rate, continuous-flow, left ventricular assist device, EVAHEART: A Japanese multicenter study using J-MACSThe Journal of Heart and Lung Transplantation, 2014
- Aortic Insufficiency in Patients With Sustained Left Ventricular Systolic Dysfunction After Axial Flow Assist Device ImplantationCirculation Journal, 2014
- Reduction of Driveline Infections Through Doubled Driveline Tunneling of Left Ventricular Assist DevicesArtificial Organs, 2013
- Working formulation for the standardization of definitions of infections in patients using ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2011