Design and Application of Corona Current Measurement System under High-Voltage Direct-Current Environment
Authors:
- Xin EnchengXEXin Encheng
- Xu RuiXRXu Rui
- Yuan HaiwenYHYuan Haiwen
- Lu JiayuLJLu Jiayu
- 1 September 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 692-696
Abstract
Transmission line corona characteristic research is one of the key technologies in high-voltage direct current (HVDC) transmission project in our country. In order to analyze conductor corona discharge characteristic under HVDC environment, a corona current measurement system is developed. In this paper, based on the finite-element method, the structure of the measuring equipment is determined. The anti-interference technology of the measuring equipment is researched and applied for accurate measurement. Research results show that, the measurement system is immune to the effects from the external electromagnetic environment and can measure corona current accurately. The corona current signal collected by optical fiber communication technology is safe and reliable. The measurement system can be used to measure the wide frequency band corona current. Corona current of the positive pole is bigger than of negative pole with the same voltage grade, and this measurement system can be used to research conductor corona characteristic.Keywords
This publication has 13 references indexed in Scilit:
- Development and Application of High-Frequency Sensor for Corona Current Measurement under Ultra High-Voltage Direct-Current EnvironmentIEEE Transactions on Instrumentation and Measurement, 2012
- Control of electromagnetic waves through electromagnetic shielding2011
- The Measurement Method for Corona Discharge Current Under High-Voltage EnvironmentIEEE Transactions on Instrumentation and Measurement, 2008
- A new hybrid current sensor for high-voltage applicationsIEEE Transactions on Power Delivery, 2005
- Development of a Portable Fiber-Optic Current Sensor for Power Systems MonitoringIEEE Transactions on Instrumentation and Measurement, 2004
- The Use of Fiber Optics for Communications, Measurement and Control Within High Voltage SubstationsIEEE Transactions on Power Apparatus and Systems, 1980
- Electromagnetic Shielding Effectiveness of Steel Sheets with Partly Welded SeamsIEEE Transactions on Electromagnetic Compatibility, 1977
- A Comparative Study of the Corona Performance of Conductor Bundles for 1200 KV Transmission LinesIEEE Transactions on Power Apparatus and Systems, 1974
- Radio Noise, Audible Noise, and Corona Loss of EHV and UHV Transmission Lines Under Rain: Predetermination Based on Cage TestsIEEE Transactions on Power Apparatus and Systems, 1970
- Analysis of Corona Losses on DC Transmission Lines: I - Unipolar LinesIEEE Transactions on Power Apparatus and Systems, 1969