A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study
Open Access
Abstract
Background: The purpose of this study was to measure and compare the strain levels in the peri-implant bone as generated by the blade-like implant (BLI) and the screw-type implant (STI) with two different internal connections (hexagonal and conical) and with a 1:1 and 2:1 crown/implant (C/I) ratio. Methods: The implants (BLI and STI) were placed into sawbones according to the manufacturer’s protocol. Two strain gauges, horizontal and vertical to the implant axis, were placed around each implant on the bone surface 1 mm from the cervical part. Each implant was loaded by a material testing machine at a force of 100 N. Micro-strains (με) generated in the surrounding bone were measured by a strain gauge and recorded. Results: Recorded micro-strains were not significant in both the insertion and loading phases (p < 0.0625). The average recorded micro-strain values were lower in the horizontal dimension of STI with hexagonal connection when the C/I ratio was 2:1 compared with BLI, 210 με and 443 με, respectively. Conclusion: Within the limitations of this study, implant design, implant-abutment connection and C/I ratio did not influence strain values in bone and there is no statistically significant effect of these parameters on bone.Keywords
This publication has 41 references indexed in Scilit:
- Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant ConfigurationImplant Dentistry, 2011
- The effect of thread pattern upon implant osseointegrationClinical Oral Implants Research, 2010
- Immediate Implant Placement After Removal of a Failed Implant: A Clinical and Histological Case ReportJournal of Oral Implantology, 2009
- Interventions for replacing missing teeth: different types of dental implants2007
- A 10‐year prospective study of ITI dental implants placed in the posterior region. II: Influence of the crown‐to‐implant ratio and different prosthetic treatment modalities on crestal bone lossClinical Oral Implants Research, 2007
- Influence of controlled immediate loading and implant design on peri‐implant bone formationJournal of Clinical Periodontology, 2006
- Immediately Loaded Blade Implant Retrieved From a Man After a 20-year Loading Period: A Histologic and Histomorphometric Case ReportJournal of Oral Implantology, 2006
- The effects of bolus size and chewing rate on masticatory performance with artificial test foodsJournal of Oral Rehabilitation, 1997
- BIOMECHANICAL CONCERNS WITH FIXED PARTIAL DENTURES INVOLVING IMPLANTSImplant Dentistry, 1993
- Implant fixation improved by close fit Cylindrical implant – bone interface studied in rabbitsActa Orthopaedica, 1988