Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zeev Ormianer has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Ameer Biadsee

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine Tel‐Aviv University Tel Aviv Israel

    6 shared publications
  • Shchada Masarwa

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Ramat Aviv, Tel Aviv 6997801, Israel

    2 shared publications
  • Tarek Mtanis

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Ramat Aviv, Tel Aviv 6997801, Israel

    2 shared publications
  • Adi Lorean

    Titu Maiorescu Univ, Fac Dent Med, Dept Oral Surg & Oral Implantol, Bucharest, Romania

    1 shared publication
  • Alina Becker

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Ramat Aviv, 69978, Tel Aviv, Israel

    1 shared publication
  • Alina Becker

    Department of Oral Rehabilitation, School of Dental Medicine, Tel-Aviv University, P.O. Box 39040, Tel Aviv 6997801, Israel

    1 shared publication

Latest Publications

  • Open Access

    Influence of Hyaluronic Acid Lip Filler Augmentation on Smile Design Parameters in Young Female Population: An Observational Study

    by Ameer Biadsee, Haya Milhem, Matityahou Ormianer, Zeev Ormianer

    Objective: To evaluate the effect of hyaluronic acid (HA) lip augmentation on anterior tooth exposure and smile‐line characteristics using three‐dimensional (3D) facial scanning technology. Materials and Methods: Twenty‐five female participants were enrolled. All injections were performed by a single experienced clinician following a standardized protocol, with a total of 1.0 mL of HA filler administered to the lips. 3D facial scans were obtained before treatment, immediately after injection, and at a 4‐week follow‐up. Maxillary left central incisor and canine exposure during smiling, as well as upper lip volume, were measured at each timepoint using dedicated software. Results: The mean participant age was 26.2 years, and the mean follow‐up period was 28.8 days. At follow‐up, maxillary central incisor and canine exposure decreased by 0.1 mm compared to pre‐treatment values ( p < 0.001). Upper lip volume increased by 0.79 mm 3 at follow‐up ( p < 0.001). An inverse correlation was observed between lip volume and central incisor exposure, indicating reduced tooth display with increased lip volume. No significant correlation was found between lip volume and canine exposure or between central incisor and canine exposure. Conclusion: HA lip augmentation was associated with small but statistically significant changes in anterior tooth exposure during smiling. These findings highlight the influence of perioral soft tissue on smile‐related dental parameters and underscore the importance of considering lip volume when planning esthetic dental and restorative treatments.

  • Open Access

    Assessing the Cleanliness of Dental Implants Using Scanning Electron Microscopy and Energy-Dispersive X-ray Spectroscopy Analysis—A SEM and EDS In Vitro Study

    by Tarek Mtanis, Ameer Biadsee, Zeev Ormianer

    A wide variety of titanium (Ti) alloy dental implant systems are available and as a result, choosing the correct system has become a challenge. Cleanliness of the dental implant surface affects osseointegration but surface cleanliness may be jeopardized during manufacturing. The purpose of this study was to assess the cleanliness of three implant systems. Fifteen implants per system were examined with scanning electron microscopy to identify and count foreign particles. Particle chemical composition analysis was performed with energy-dispersive X-ray spectroscopy. Particles were categorized according to size and location. Particles on the outer and inner threads were quantitatively compared. A second scan was performed after exposing the implants to room air for 10 min. Carbon, among other elements, was found on the surface of all implant groups. Zimmer Biomet dental implants had higher particle numbers than other brands. Cortex and Keystone dental implants showed similar distribution patterns. The outer surface had higher particle numbers. Cortex dental implants were the cleanest. The change in particle numbers after exposure was not significant (p > 0.05). Conclusion: Most of the implants studied were contaminated. Particle distribution patterns vary with the manufacturer. The wider and outer areas of the implant have a higher probability of contamination.


  • Open Access

    Effect of Titanium-Base Abutment Height on Optical Properties of Monolithic Anterior Zirconia Crowns

    by Ameer Biadsee, Mutlu Özcan, Lubaba Masarwa, Mishel Haddad, Nadin Al-Haj Husain, Zeev Ormianer

    The effects of different heights of ti-base abutments on the color of anterior screw-retained zirconia restorations fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technologies may affect the optical clinical outcome. The purpose of this study was to measure and compare the color parameters of zirconia crowns in different shades on ti-base abutments. Identical specimens (N = 160) were milled to restore the screw-retained central maxillary incisor crown, using 5% mol yttria zirconia (5Y-TZP). The specimens were designed using computer design software to match 3.5 mm and 5.5-mm ti-base abutments and milled using one CAD-CAM technology. Specimens were divided into four main groups depending on zirconia shade (A1/0, A2/3, A3.5/4 and B2/3) and then assigned to two subgroups according to ti-base height. Color measurements in the CIELab coordinates were made using a spectrophotometer under room-light conditions. Color difference (ΔE*) values were calculated using the CIE76 and CIEDE2000 formula. Within the group of A0/1 and A2/3, for 5.5 mm abutment height, a significant difference was found between the means of colors ∆E00 and ∆Eab (p < 0.01). Using a 5.5 mm-height ti-base abutment may produce a clinically unacceptable outcome (ΔEab > 2) in A1/0 and A2/3 color groups.


  • Open Access

    A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study

    by Riyam Kassem, Amar Samara, Ameer Biadsee, Shchada Masarwa, Tarek Mtanis, Zeev Ormianer

    Background: The purpose of this study was to measure and compare the strain levels in the peri-implant bone as generated by the blade-like implant (BLI) and the screw-type implant (STI) with two different internal connections (hexagonal and conical) and with a 1:1 and 2:1 crown/implant (C/I) ratio. Methods: The implants (BLI and STI) were placed into sawbones according to the manufacturer’s protocol. Two strain gauges, horizontal and vertical to the implant axis, were placed around each implant on the bone surface 1 mm from the cervical part. Each implant was loaded by a material testing machine at a force of 100 N. Micro-strains (με) generated in the surrounding bone were measured by a strain gauge and recorded. Results: Recorded micro-strains were not significant in both the insertion and loading phases (p < 0.0625). The average recorded micro-strain values were lower in the horizontal dimension of STI with hexagonal connection when the C/I ratio was 2:1 compared with BLI, 210 με and 443 με, respectively. Conclusion: Within the limitations of this study, implant design, implant-abutment connection and C/I ratio did not influence strain values in bone and there is no statistically significant effect of these parameters on bone.


  • Open Access

    The Effect of Various Cementing Agents on Occlusal Discrepancy Using an Intra-Oral Scanner: An In Vivo Study

    by Ameer Biadsee, Rana Yassin, Eran Dolev, Vladimir Perlis, Shchada Masarwa, Zeev Ormianer

    A marginal fit of all-ceramic crowns is a prerequisite for the long-term clinical success of a dental restoration. Few in vivo studies have investigated the effect of the film thickness of various luting agents on vertical discrepancy. This in vivo study evaluated the influence of three luting cements on the occlusal vertical discrepancy of milled crowns using a complete digital workflow. Forty-three patients treated in a students’ clinic in Tel-Aviv University with 45 single posterior digitally prepared monolithic crowns were included in the study. The crowns were randomly divided into three groups using different resin luting agents: self-adhesive resin cement, resin-modified glass ionomer cement and adhesive resin cement. The crowns were intra-orally scanned before and after cementation. The two standard tessellation language (STL) files for each crown were superimposed using digital software, and between four and six measurements were made at the occlusal surface to demonstrate the occlusal and marginal discrepancies. One-way ANOVA (α = 0.05) was used. The vertical occlusal discrepancy ranged from 2 to 38 μm. The mean vertical discrepancy values were (µm): self-adhesive resin = 12.93 ± 4.74, resin-modified glass ionomer = 19.05 ± 4.60 and adhesive resin = 13.69 ± 5.17. There were significant differences between resin-modified and self-adhesive cement groups (p = 0.004), and between resin-modified and adhesive resin cement groups (p = 0.013). Distal marginal ridge measurements were significantly different between resin-modified glass ionomer cement and self-adhesive resin cement group (p < 0.001) and the adhesive resin cement group (p = 0.021). There were no significant differences between the discrepancy values at the two measurement points in the self-adhesive cement group (p = 0.377), nor the resin-modified glass ionomer group (p = 0.388), or the adhesive resin cement group (p = 0.905). The cementation procedure with various resin cements results in occlusal vertical discrepancies within standard clinical acceptability. Resin-modified glass ionomer cement produced more vertical discrepancy than adhesive and self-adhesive resin cements did.


  • Open Access

    Thermal Cycling Effect on Locator System Retention and Metal Surface Roughness

    by Vladimir Perlis, Tarek Mtanis, Ameer Biadsee, Zeev Ormianer

    Purpose: To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them.Materials and methods: Twenty‐five new Locator R‐Tx were included in the study. Four areas were marked on each Locators’ patrix metal surface and scanned using a confocal scanner (μsurf explorer; NanoFocus). Three surface roughness parameters were measured in the scans: Sa (average distance of peaks from the central plain of the area), Vmp (volume of the peaks in the area), and Spc (mean curvature of the peaks describing the degree of their sharpness). Retention test was performed using Instron® 4500 compression tension tensile tester at a speed of 10 mm/min. The retention tests were done using a working model made of two acrylic blocks in which the Locator system parts were inserted. The surface parameters measurements and the retention tests were performed 2 times, once before and once after TC. The Locators were subjected to 15,000 TC cycles by investing them into 2 tubs with different water temperatures, 55°C and 5°C. During each 60‐second cycle, the Locators were submerged in each tub for 20 seconds, with a 10 second transition time between the tubs. The post‐TC retention and surface parameters measurements were compared with those prior to TC and the prior to TC measurements served as controls. Changes in parameters before and after TC were analyzed by a two‐way ANOVA nested model with random intercept and slope by restricted maximum likelihood method. Correlation between retention and surface parameters was quantified and examined using Kendall's correlation test. The findings were considered statistically significant if p < 0.05.Results: There was a significant decrease in retention of 16.6N at the second retention test (p < 0.001). A significant statistical decrease in surface parameters were measured after TC process, Sa and Vmp (18 ×10–3 μm, p = 0.041 and 0.94 ×10–3 1/μm, p = 0.001, respectively). A significant statistical increase in Spc of 6.4 ×10–3 μm3/μm2 (p = 0.023) was noticed. The correlation between retention decreases and surface changes was not statistically significant.Conclusion: The TC process causes a substantial reduction in retention to the Locator system over time. In addition, TC causes significant but minor changes to the Locator surface area. Most of the changes are in the horizontal dimension.


  • Open Access

    Effects of Aging Torque Controllers on Screw Tightening Force and Bacterial Micro-Leakage on the Implant-Abutment Complex

    by Yousef Jiries, Tamar Brosh, Shlomo Matalon, Vladimir Perlis, Zeev Ormianer

    Aim: We assess the accuracy of torque controllers after several aging processes and the bacterial leakage on implant-abutment complexes (IAC). Methods: A total of 12 spring-type and 12 friction-type torque controllers and 48 IAC (24 conical and 24 hexagonal connections) were evaluated. Chemical, mechanical, temperature, and pressure-aging methods were applied individually to replicate clinical use. Torque controller accuracy was analyzed before and after aging using a calibrated gauge. To assess bacterial leakage, the IAC were suspended in a bacterial medium for 24 h. Direct Contact Test (DCT) and Polymerase Chain Reaction Test (RT-PCR) analyzed the infiltration of F. nucleatum and P. gingivalis into the IAC micro-gap. Results: A significant decrease in torque after 10 days of aging was found. The spring-type torque controller was affected the most, regardless of the aging method (P < 0.05). PCR results indicated that all groups exhibited significantly more bacterial leakage, regardless of the method used (P < 0.05). The conical IAC demonstrated more bacterial leakage of P. gingivalis compared with the hexagonal IAC (P = 0.07). DCT found bacterial growth in the IAC only before aging and was not identified after aging. Conclusion: Aging affects torque accuracy. A reduction in force was noticed after 10 days. The conical IAC exhibits more bacterial leakage, although this was not statistically significant.


  • Marginal Bone Loss of Dental Implants in Patients with Type 2 Diabetes Mellitus with Poorly Controlled HbA1c Values: A Long-Term Retrospective Study

    by Adi Lorean, Hila Ziv-On, Vladimir Perlis, Zeev Ormianer

    Purpose: The objective of this study was to report implant survival rates, marginal bone loss, and the impact of prosthesis type among patients with type 2 diabetes mellitus (DMT2), with high hemoglobin A1C (HbA1c) values. Materials and Methods: This retrospective study utilized patient medical records from an oral surgeon's office. Patients who had moderately or poorly controlled DMT2 with HbA1c values up to 10% were reviewed. Inclusion criteria were partially or fully edentulous patients diagnosed with DMT2 who were subsequently treated with implant-supported prosthetic restorations. Patients were at least 18 years of age. Exclusion criteria were patients who did not present for annual follow-up visits, patient records with incomplete surgical or restorative data, or nondiagnostic radiographs. All the fixed restorations were cement-retained, and the removable restorations were supported by two to six implants. Marginal bone loss and the consequences of prosthetic type were assessed from the last available radiograph compared with the one taken after the surgical procedure. Results: Data of 357 implants were extracted from the records of 38 patients with HbA1c values (6.9% to 10.0%). The mean follow-up was 7.3 years, with a minimum of 5 years. Six implants failed, yielding a 98.4% overall implant survival rate. The patients were divided into two groups according to the HbA1c values before implant placement. The moderately controlled group included 25 patients with DMT2, with HbA1c values of 6.9% to 8.0%, and the poorly controlled group included 13 patients, with HbA1c values of 8.1% to 10.0%. The overall mean bone loss was 2.02 +/- 2.43 mm. In both groups, the maxilla demonstrated more bone loss than the mandible (P<.05). Marginal bone loss in moderately controlled and poorly controlled groups was 1.86 (+/- 2.21) mm and 2.33 (+/- 2.85) mm, respectively (P<.05). Removable prostheses also revealed greater bone loss rates compared with fixed prostheses in both groups (P<.05). Conclusion: Patients with high HbA1c values (8.1% to 10.0%) had more marginal bone loss than those with lower HbA1c values. Removable dentures should be reconsidered as a standard treatment option in these patients.


  • The Effect of Aging on the Roughness and Bacterial Adhesion of Lithium Disilicate and Zirconia Ceramics

    by Shlomo Matalon, Dana Safadi, Avi Meirowitz, Zeev Ormianer

    Purpose: This in vitro study was designed to compare bacterial adhesion to zirconia versus lithium disilicate crowns after artificial aging.Materials and Methods: Seventy‐five discs were tested in this study: 25 Cr‐Co base metal discs (control), 25 zirconia discs, and 25 lithium disilicate discs. Each sample was polished and glazed appropriately. The discs were subjected to 1000 thermal cycles between 5 and 55°C, whereby samples stayed in the bath for 20 seconds, at each temperature. Then, 10 µL of Streptococcus sanguinis suspension was placed on the discs. The samples were scanned for surface roughness before and after aging, and after incubation. Sp and Sa were measured with a confocal, visible light disk‐scanning system (Sa expresses the difference in height of each point compared to the arithmetical mean of the surface. Sp is the height of the highest peak within the defined area). Optical density of the discs was evaluated by a spectrophotometer. One‐way ANOVA was performed to assess differences after aging and incubation.Results: Statistical analysis showed significant differences (p = 0.02) in surface roughness between the Cr‐Co base metal, zirconia and lithium disilicate before and after aging. The mean Sa was 0.36 ± 0.12 µm, 0.638 ± 0.24 µm, and 1.23 ± 0.42 µm, respectively. Lithium disilicate had the highest surface roughness values. There was a significant difference (p = 0.001) after incubation. The mean and standard deviation surface roughness of Cr‐Co base metal, zirconia and lithium disilicate were 0.99 ± 0.49 µm, 1.40 ± 0.46 µm, and 2.44 ± 1.21 µm, respectively.While no significant differences were found in the accumulation of S. sanguinis between zirconia and lithium disilicate, there was a significant difference (p = 0.02) in the optical density between these 2 test groups and the control group (metal). The optical density of metal (0.94 ± 0.15) was higher than for lithium disilicate (0.74 ± 0.10) and zirconia (0.75 ± 0.08). There was no statistical difference in bacterial adherence between lithium disilicate and zirconia.Conclusion: Dental crown materials differed significantly in terms of surface roughness and bacterial adhesion between Cr‐Co base metal and zirconia and lithium disilicate. After aging and bacterial adherence, the zirconia discs had the smoothest surface, with similar bacterial accumulation as lithium disilicate; suggesting that lithium disilicate may be less sensitive to bacterial adhesion than zirconia.