A linear relationship for the LET-dependence of Gafchromic EBT3 film in spot-scanning proton therapy
- 1 March 2019
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (5) , 055015
Abstract
Radiochromic film (RCF) is a valuable dosimetric tool, primarily due to its sub-millimeter spatial resolution. For accurate proton dosimetry, the dependence of film response on linear energy transfer (LET) must be characterized and calibrated. In this work, we characterized film under-response, or ‘quenching’, as a function of dose-weighted linear energy transfer (LET d ) in several proton fields and established a simple, linear relationship with LET d . We performed measurements as a function of depth in a PMMA phantom irradiated by a spot-scanning proton beam. The fields had energies of 71.3 MeV, 71.3 MeV with filter, and 159.9 MeV. At each depth (measurements taken in depth step sizes of 0.5–1 mm in the Bragg peak), we measured dose with a PTW Markus ion chamber and EBT3 RCF. EBT3 under-response was characterized by the ratio of dose measured with film to that with ion chamber. LET d values for our experimental setup were calculated using in-house clinical Monte Carlo code. Measured film under-response increased with LET d , from approximately 10% under-response for LET d = 5 keV µ m −1 to approximately 20% for LET d = 8 keV µ m −1 . The under-response for all measurements was plotted versus LET d . A linear fit to the data was performed, yielding a function for under-response, , with respect to LET d : . Finally, the linear under-response relationship was applied to a film measurement within a spread-out Bragg peak (SOBP). Without correcting for LET d -dependence in the SOBP measurement, the discrepancy between film and Monte Carlo profiles was greater than 15% at the distal edge. With correction, the corrected film profile was within 2% and 1 mm of the Monte Carlo profile. RCF response depends on LET d , potentially under-responding by >15% in clinically-relevant scenarios. Therefore, it is insufficient to perform only a dose calibration; LET calibration is also necessary for accurate proton film dosimetry. The LET d -dependence of EBT3 can be described by a single, linear function over a range of clinically-relevant proton therapy LET d values.Keywords
This publication has 22 references indexed in Scilit:
- Microdosimetric measurements of a clinical proton beam with micrometer‐sized solid‐state detectorMedical Physics, 2017
- Measurements of 2D distributions of absorbed dose in protontherapy with Gafchromic EBT3 filmsApplied Radiation and Isotopes, 2015
- Under-response correction for EBT3 films in the presence of proton spread out Bragg peaksPhysica Medica, 2014
- An anthropomorphic spine phantom for proton beam approval in NCI-funded trialsJournal of Applied Clinical Medical Physics, 2014
- Development and validation of radiochromic film dosimetry and Monte Carlo simulation tools for acquisition of absolute, high-spatial resolution longitudinal dose distributions in ocular proton therapyRadiation Measurements, 2013
- Radiochromic EBT2 film dosimetry for low‐energy protontherapyMedical Physics, 2011
- Dosimetry and spectral analysis of a radiobiological experiment using laser-driven proton beamsPhysics in Medicine & Biology, 2011
- Radiochromic film dosimetry: Past, present, and futurePhysica Medica, 2011
- Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertaintiesPhysics in Medicine & Biology, 2011
- LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetryPhysics in Medicine & Biology, 2009