Dynamics in longitudinal eye movements and corneal shape
- 13 October 2006
- journal article
- case report
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 26 (6) , 572-579
Abstract
The magnitude and character of longitudinal movements of the eye were studied in the context of high speed videokeratoscopy. It was of interest to determine whether these dynamic changes in the eye movements can affect the corneal shape and its estimation. A high speed videokeratoscope with a sampling frequency of 50 Hz was used for measuring the corneal apex movements as well as for measuring variations in the best‐fit sphere radius and central radius of curvature. The magnitude of the measured longitudinal apex movements could reach over 200 μ m showing a slow trend. The estimated local changes of the apex movements that could be associated with the cardiopulmonary system were about 40–50 μ m. The temporal variations in the equivalent estimated central radius of curvature ranged between 10 and 15 μ m. Spectral analysis of the longitudinal eye movements revealed strong signatures of the pulse and respiration signals as well as the assumed blink control signal. No clear association between the longitudinal apex movements and the corneal curvature was found. However, very slow significant changes in the corneal shape were observed. The central radius of curvature of the cornea revealed slow changes of up to 120 μ m. Understanding the nature of such changes will be of benefit in ophthalmic applications requiring highly accurate measurements of corneal shape, such as contact lens design and refractive surgery.Keywords
This publication has 23 references indexed in Scilit:
- Influence of intraocular pressure on geometrical properties of a linear model of the eyeball: Effect of optical self-adjustmentOptik, 2004
- Corneal Topography and AccommodationCornea, 2003
- Consideration of Three Types of Spontaneous Eyeblink Activity in Normal Humans: during Reading and Video Display Terminal Use, in Primary Gaze, and while in ConversationOptometry and Vision Science, 2001
- Dominant frequency content of ocular microtremor from normal subjectsVision Research, 1999
- Microfluctuations of steady-state accommodation and the cardiopulmonary systemVision Research, 1995
- Measurement of Elastic Modulus of the Central Bovine Cornea by Means of Holographic Interferometry. Part II. ResultsOptometry and Vision Science, 1994
- The synkinesis between antero‐posterior eye position and lid fissure widthClinical and Experimental Optometry, 1992
- Human gaze stability in the horizontal, vertical and torsional direction during voluntary head movements, evaluated with a three-dimensional scleral induction coil techniqueVision Research, 1987
- A Computational Approach to Edge DetectionIEEE Transactions on Pattern Analysis and Machine Intelligence, 1986
- Respiratory sinus arrhythmia: a frequency dependent phenomenonJournal of Applied Physiology, 1964