DID. Robert Iskander

D. Robert Iskander

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


D. Robert Iskander has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Michael J. Collins

    Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia

    6 shared publications
  • Henryk T. Kasprzak

    Institute of Physics, Wroclaw University of Technology, Poland

    2 shared publications
  • Larry N. Thibos

    School of Optometry, Indiana University, Bloomington, IN, USA

    2 shared publications
  • Ross Franklin

    Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Qld, Australia

    2 shared publications
  • BRETT A. BAppSc DAVIS

    Contact Lens and Visual Optics Laboratory School of Optometry Queensland University of Technology Brisbane Australia

    1 shared publication
  • Brett A. Davis

    Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Qld, Australia

    1 shared publication

Latest Publications

  • Ultrasonic In Vivo Measurement of Ocular Surface Expansion

    by Malgorzata A Kowalska, Henryk T. Kasprzak, D. Robert Iskander, Monika Danielewska, David Mas

    Our aim was to ascertain whether the ultrasonic measurement of longitudinal corneal apex displacements carried out in a proper headrest is a credible method of ocular pulse (OP) detection. To distinguish between longitudinal movements of the eye globe treated as a rigid body and ocular surface expansion caused by the variations of the eye-globe volume, two ultrasound distance sensors were applied to noninvasively measure displacements of cornea and sclera. The same sensors were used to examine the influence of the anterio-posterior movements of a fixed head on the registration of corneal apex pulsation. In both experiments, ECG signals were synchronically recorded. Time, spectral, and coherence analyses obtained for four healthy subjects showed that the ocular surface expansion due to pulsatile ocular blood flow (POBF) is the main component of longitudinal corneal displacement. Ocular surface pulsation is always affected by the head movement. However, there exist some unique properties of signals, which help to distinguish between head and eye movements. A rigid headrest and a bite bar are required to stabilize the head during OP measurement. Ultrasonic technique enables noninvasive and accurate in vivo measurement of corneal pulsation, which could be of interest for indirectly estimating intraocular pressure propagation and POBF component.


  • Open Access

    Estimation of the depth of focus from wavefront measurements

    by Fan Yi, D. Robert Iskander, Michael J. Collins

    It is possible to estimate the depth of focus (DOF) of the eye directly from wavefront measurements using various retinal image quality metrics (IQMs). In such methods, DOF is defined as the range of defocus error that degrades the retinal image quality calculated from IQMs to a certain level of the maximum value. Although different retinal image quality metrics are used, currently there have been two arbitrary threshold levels adopted, 50% and 80%. There has been limited study of the relationship between these threshold levels and the actual measured DOF. We measured the subjective DOF in a group of 17 normal subjects and used through-focus augmented visual Strehl ratio based on optical transfer function (VSOTF) derived from their wavefront aberrations as the IQM. For each subject, a VSOTF threshold level was derived that would match the subjectively measured DOF. Significant correlation was found between the subject's estimated threshold level and the HOA RMS (Pearson's r = 0.88, p < 0.001). The linear correlation can be used to estimate the threshold level for each individual subject, subsequently leading to a method for estimating individual's DOF from a single measurement of their wavefront aberrations.


  • Modeling Videokeratoscopic Height Data with Spherical Harmonics

    by D Robert Iskander

    Purpose.: All currently considered parametric models used for decomposing videokeratoscopy height data are viewer‐centered and hence describe what the operator sees rather than what the surface is. The purpose of this study was to ascertain the applicability of an object‐centered representation to modeling of corneal surfaces. Methods.: A three‐dimensional surface decomposition into a series of spherical harmonics is considered and compared with the traditional Zernike polynomial expansion for a range of videokeratoscopic height data. Results.: Spherical harmonic decomposition led to significantly better fits to corneal surfaces (in terms of the root mean square error values) than the corresponding Zernike polynomial expansions with the same number of coefficients, for all considered corneal surfaces, corneal diameters, and model orders. Conclusions.: Spherical harmonic decomposition is a viable alternative to Zernike polynomial decomposition. It achieves better fits to videokeratoscopic height data and has the advantage of an object‐centered representation that could be particularly suited to the analysis of multiple corneal measurements.


  • The statistics of refractive error maps: managing wavefront aberration analysis without Zernike polynomials

    by D. Robert Iskander, Jayoung Nam, Larry N. Thibos

    The refractive error of a human eye varies across the pupil and therefore may be treated as a random variable. The probability distribution of this random variable provides a means for assessing the main refractive properties of the eye without the necessity of traditional functional representation of wavefront aberrations. To demonstrate this approach, the statistical properties of refractive error maps are investigated. Closed‐form expressions are derived for the probability density function (PDF) and its statistical moments for the general case of rotationally‐symmetric aberrations. A closed‐form expression for a PDF for a general non‐rotationally symmetric wavefront aberration is difficult to derive. However, for specific cases, such as astigmatism, a closed‐form expression of the PDF can be obtained. Further, interpretation of the distribution of the refractive error map as well as its moments is provided for a range of wavefront aberrations measured in real eyes. These are evaluated using a kernel density and sample moments estimators. It is concluded that the refractive error domain allows non‐functional analysis of wavefront aberrations based on simple statistics in the form of its sample moments. Clinicians may find this approach to wavefront analysis easier to interpret due to the clinical familiarity and intuitive appeal of refractive error maps.


  • Phase Reconstruction using Zernike Orthogonal Slope Polynomials

    by Jayoung Nam, Larry N. Thibos, D. Robert Iskander

    We develop Zernike radial slope polynomials for phase reconstruction from wavefront slope data. These new polynomials form an orthonormal set for gradient data and thus avoid problems encountered when using spatial-derivatives of ordinary Zernike polynomials.

  • The "Hook and Loop" Resampling Plane

    by D. Robert Iskander, Weaam Alkhaldi

    We propose a new resampling scheme that takes literally the concept of the non-parametric bootstrap in which new samples are generated from the empirical distribution function. The introduced resampling concept is totally heuristic, but already shows promising results when applied to model selection. We show that for a range of linear models, the proposed resampling scheme outperforms the classical model selection techniques as well as its predecessor, the non-parametric bootstrap. It also simplifies the practical problem of choosing residual scaling or the length of the subsample that exists in the traditional bootstrap based model selection approach.


  • Extrapolation of Central Corneal Topography Into the Periphery

    by D Robert Iskander, Michael J. Collins, Scott A. Read

    Purpose. To investigate the errors associated with extrapolating the topography of the central cornea into the peripheral cornea. Methods. Corneal topography data previously acquired from 92 young adult subjects was used. These data were collected and analyzed by using a method that allows central and peripheral maps to be combined to produce an extended corneal topography map that reaches close to the limbus. By using the central 5-, 6-, and 7-mm corneal topography that would normally be acquired in a single measurement, various mathematical techniques were applied to extrapolate the central topography into the periphery. These mathematical techniques included the use of simple conics, generalized conics, cosine hyperbolic functions, and a set of fourth, sixth, and eighth radial order polynomials. The root-mean-square error between the extrapolated topography and true extended topography at various diameters was then compared. Results. The root-mean-square errors in the outer extrapolated region ranged from 30 to 220 μm, depending on the fit function used. The lowest errors were achieved with the conic fits, cosine hyperbolic functions, and fourth and sixth radial order polynomials, with root-mean-square error levels of approximately 30 to 40 μm. The variables of global versus meridional fitting, centering the data on the geometric center versus vertex normal, the regional quadrant, and the diameter of the central topography used had relatively little influence on the fit errors. Conclusions. Extrapolation from central corneal topography into the periphery by using radial polynomials of the fourth order provides the lowest levels of fit errors for normal corneas.


  • The Skew Ray Ambiguity in the Analysis of Videokeratoscopic Data

    by D Robert Iskander, BRETT A. BAppSc DAVIS, MICHAEL J. PhD COLLINS

    Purpose.: Skew ray ambiguity is present in most videokeratoscopic measurements when azimuthal components of the corneal curvature are not taken into account. There have been some reported studies based on theoretical predictions and measured test surfaces suggesting that skew ray ambiguity is significant for highly deformed corneas or decentered corneal measurements. However, the effect of skew ray ambiguity in ray tracing through videokeratoscopic data has not been studied in depth. Methods.: We have evaluated the significance of the skew ray ambiguity and its effect on the analyzed corneal optics. This has been achieved by devising a procedure in which we compared the corneal wavefront aberrations estimated from 3D ray tracing with those determined from 2D (meridional based) estimates of the refractive power. The latter was possible due to recently developed concept of refractive Zernike power polynomials which links the refractive power domain with that of the wavefront. Simulated corneal surfaces as well as data from a range of corneas (from two different Placido disk‐based videokeratoscopes) were used to find the limit at which the difference in estimated corneal wavefronts (or the corresponding refractive powers) would have clinical significance (e.g., equivalent to 0.125 D or more). Results.: The inclusion/exclusion of the skew ray in the analyses showed some differences in the results. However, the proposed procedure showed clinically significant differences only for highly deformed corneas and only for large corneal diameters. Conclusions.: For the overwhelming majority of surfaces, the skew ray ambiguity is not a clinically significant issue in the analysis of the videokeratoscopic data indicating that the meridional processing such as that encountered in calculation of the refractive power maps is adequate.


  • Objective refraction from monochromatic wavefront aberrations via Zernike power polynomials

    by D. Robert Iskander, Brett A. Davis, Michael J. Collins, Ross Franklin

    With the increased popularity of wavefront sensor devices there has been significant interest in relating the subjectively measured sphero‐cylindrical refractive error to the objectively measured wavefront aberrations. We investigate the applicability of four different measures for objective refraction assessment that are derived from a set of estimated Zernike wavefront coefficients. Two of the measures are based on the second‐ and higher‐order Zernike polynomials while the other two measures are based on the estimated dioptric power representations. For the latter, closed‐form expressions for dioptric powers based on the estimated focal length and the wavefront curvature are derived. We call these two new representations the ‘refractive Zernike power polynomials’ and ‘curvature Zernike power polynomials’. Data from 120 eyes from 60 normal subjects were used to assess the correlation between the subjective and objective refractions. The results indicate that the objective sphero‐cylindrical refraction calculated from the estimated refractive power map via the Zernike power polynomials is superior to the other considered representations and achieves best correlation with subjective sphero‐cylindrical refraction.


  • Dynamics in longitudinal eye movements and corneal shape

    by D. Robert Iskander, Henryk T. Kasprzak

    The magnitude and character of longitudinal movements of the eye were studied in the context of high speed videokeratoscopy. It was of interest to determine whether these dynamic changes in the eye movements can affect the corneal shape and its estimation. A high speed videokeratoscope with a sampling frequency of 50 Hz was used for measuring the corneal apex movements as well as for measuring variations in the best‐fit sphere radius and central radius of curvature. The magnitude of the measured longitudinal apex movements could reach over 200 μ m showing a slow trend. The estimated local changes of the apex movements that could be associated with the cardiopulmonary system were about 40–50 μ m. The temporal variations in the equivalent estimated central radius of curvature ranged between 10 and 15 μ m. Spectral analysis of the longitudinal eye movements revealed strong signatures of the pulse and respiration signals as well as the assumed blink control signal. No clear association between the longitudinal apex movements and the corneal curvature was found. However, very slow significant changes in the corneal shape were observed. The central radius of curvature of the cornea revealed slow changes of up to 120 μ m. Understanding the nature of such changes will be of benefit in ophthalmic applications requiring highly accurate measurements of corneal shape, such as contact lens design and refractive surgery.