Automatic delineation for replanning in nasopharynx radiotherapy: What is the agreement among experts to be considered as benchmark?
Open Access
- 19 August 2013
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 52 (7) , 1417-1422
Abstract
Background and purpose. Anatomic changes during head and neck radiotherapy require replanning. The primary aim of this study is the definition of the agreement among experts in the head and neck automatic delineation frame to use as benchmark. The secondary goal is to assess the reliability of automatic delineation for nasopharynx radiotherapy and time saving. Material and methods. A computed tomography (CT) scan was acquired in 10 nasopharynx patients along intensity-modulated radiotherapy (IMRT) treatment for replanning. Deformable registration with replanning autocontouring of the structures was performed using VelocityAI 2.3© software defining Structure Set A. The optimization of these contours was obtained through revision by a skilled operator, drawing Structure Set B. An ex novo Structure Set C was segmented on the replanning CT-scan by an expert delineation team. The mean Dice's Similarity Index (mDSI) was calculated between Structure Set A and B, A and C, and between B and C for each volume. All segmentation times for organs at risk (OARs) and clinical target volume (CTV) were recorded and compared. Results. We validated the replanning autocontoured Structure Sets for 10 patients. For volumetric analysis we observed mDSI values of 0.87 for the OARs, 0.70 for nodes, 0.90 for CTV in the Structure Set A-B comparison and respectively of 0.74, 0.63 and 0.78 for the Structure Set A-C one, and 0.78, 0.78 and 0.85 for Structure Set B-C, which represents the existing expert based benchmark. We calculated a mean saved time in Structure Set B of 30 minutes. Conclusions. Autocontouring procedures offer considerable segmentation time saving with acceptable reliability of the contours, even if an independent check procedure for their optimization is still required to increase their adherence to referential benchmark gold standard among experts, which stands at a 0.80 DSI value.Keywords
This publication has 22 references indexed in Scilit:
- Automatic segmentation of male pelvic anatomy on computed tomography images: a comparison with multiple observers in the context of a multicentre clinical trialRadiation Oncology, 2013
- Volume and dosimetric changes and initial clinical experience of a two-step adaptive intensity modulated radiation therapy (IMRT) scheme for head and neck cancerRadiotherapy and Oncology, 2013
- Adaptive radiotherapy for head and neck cancer—Dosimetric results from a prospective clinical trialRadiotherapy and Oncology, 2013
- Weight loss in patients with head and neck cancer during and after conventional and accelerated radiotherapyActa Oncologica, 2012
- Current challenges in clinical target volume definition: Tumour margins and microscopic extensionsActa Oncologica, 2012
- A System for Continual Quality Improvement of Normal Tissue Delineation for Radiation Therapy Treatment PlanningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- A multi-institution evaluation of deformable image registration algorithms for automatic organ delineation in adaptive head and neck radiotherapyRadiation Oncology, 2012
- 3D Variation in delineation of head and neck organs at riskRadiation Oncology, 2012
- Dosimetric Evaluation of Automatic Segmentation for Adaptive IMRT for Head-and-Neck CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945