Abstract
To evaluate and compare toric intraocular lens (IOL) implantation and spherical IOL implantation with peripheral corneal relaxing incisions to manage astigmatism during phacoemulsification. Ophthalmology Service, Hospital Ramón y Cajal, Madrid, Spain. Prospective randomized comparative case series. Eyes with cataract and corneal astigmatism (1.00 to 3.00 diopters [D]) had toric IOL implantation or peripheral corneal relaxing incisions. Outcome measures were visual outcomes, slitlamp assessment, digital toric IOL axis determination, spectacle need, and patient satisfaction. Three months postoperatively, the mean uncorrected distance visual acuity (UDVA) was 0.13 ± 0.10 (SD) in the toric IOL group and 0.19 ± 0.12 in the relaxing incisions group; the UDVA was better than 0.20 in 75% of eyes and 60% of eyes, respectively. Refractive cylinder decreased significantly in both groups, with a mean residual refractive astigmatism of 0.61 ± 0.41 D in the toric IOL group and 1.32 ± 0.60 D in the relaxing incisions group (P<.01). The mean toric IOL rotation was 3.65 ± 2.96 degrees, with no significant differences between slitlamp and digital photograph measurements. There was a trend toward better mesopic contrast sensitivity with glare in the toric IOL group. There were no differences in VF-14 or patient satisfaction results; 15% of patients in the toric IOL group and 45% in the relaxing-incision group required distance spectacles postoperatively. Although refractive astigmatism decreased in both groups, toric IOL implantation was more effective and predictable, resulting in greater spectacle independence.Keywords
This publication has 19 references indexed in Scilit:
- Prevalence of corneal astigmatism before cataract surgeryJournal of Cataract & Refractive Surgery, 2009
- Correction of astigmatism at the time of cataract surgeryCurrent Opinion in Ophthalmology, 2009
- Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lensesJournal of Cataract & Refractive Surgery, 2008
- Prevalence of Refractive Error in the United States, 1999-2004Archives of Ophthalmology (1950), 2008
- Foldable toric intraocular lens for astigmatism correction in cataract patientsJournal of Cataract & Refractive Surgery, 2008
- Limbal Relaxing Incisions to Correct Corneal Astigmatism During PhacoemulsificationJournal of Refractive Surgery, 2007
- Status of toric intraocular lensesCurrent Opinion in Ophthalmology, 2007
- Analysis of patients with good uncorrected distance and near vision after monofocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2006
- Limbal relaxing incisions versus on-axis incisions to reduce corneal astigmatism at the time of cataract surgeryJournal of Cataract & Refractive Surgery, 2005
- Limbal relaxing incisions in congenital astigmatism: 6 month follow-upJournal of Cataract & Refractive Surgery, 2001