Fault Diagnosis and System Reconfiguration Strategy of Single-phase Three Level Neutral-Point-Clamped Cascaded Inverter
- 25 February 2019
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Abstract
This paper presents a fault diagnosis method and system reconfiguration strategy of three level neutral-pointclamped cascaded inverter (3L-NPC-CI) to enhance reliability of power supply in electrified railway. First, neural network is employed to perform open-circuit fault diagnosis and identify fault switches. Then, system reconfiguration strategy is proposed to perform single phase 3L-NPC-CI reconfiguration. Through the analysis of the operation status of 3L-NPC, there are eight fault modes in single bridge arm, including single-switch fault and double-switches fault. By the feature analysis for the output arm voltage harmonic of normal and eight fault modes, seven harmonic parameters are selected as fault feature vectors. Meanwhile, a three-layer neural network is constructed, and the seven feature vectors are the input layer of the neural network. By training algorithm, the fault switches location can be identified accurately about one modulation period. Then, the fault module is bypassed and the 3L-NPC-CI system is stable by reconfiguring the modulation strategy of other normal modular. Simulation and experimental results are given to validate the proposed fault diagnosis and system reconfiguration strategy. The proposed method is able to improve robustness and reliability of 3L-NPCCI in traction power supply system.Keywords
Funding Information
- National Rail Transit Electrification and Automation Engineering Technique Research Center (NEEC-2017-A01)
- This work is supported by the National Natural Science Foundation of China (51477144)
This publication has 29 references indexed in Scilit:
- Opposite Vector Based Phase Shift Carrier Space Vector Pulse Width Modulation for Extending the Voltage Balance Region in Single-Phase 3LNPC Cascaded RectifierIEEE Transactions on Power Electronics, 2016
- Open-Circuit Fault Diagnosis and Fault-Tolerant Control for a Grid-Connected NPC InverterIEEE Transactions on Power Electronics, 2015
- Fault Diagnosis and Tolerant Control of Single IGBT Open-Circuit Failure in Modular Multilevel ConvertersIEEE Transactions on Power Electronics, 2015
- A Real-Time Multiple Open-Circuit Fault Diagnosis Method in Voltage-Source-Inverter Fed Vector Controlled DrivesIEEE Transactions on Power Electronics, 2015
- Advanced Cophase Traction Power Supply System Based on Three-Phase to Single-Phase ConverterIEEE Transactions on Power Electronics, 2014
- Survey of Fault-Tolerance Techniques for Three-Phase Voltage Source InvertersIEEE Transactions on Industrial Electronics, 2014
- A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current ErrorsIEEE Transactions on Industrial Electronics, 2012
- Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based TechniquesIEEE Transactions on Industrial Electronics, 2007
- Fault detection of open-switch damage in voltage-fed PWM motor drive systemsIEEE Transactions on Power Electronics, 2003
- A New Neutral-Point-Clamped PWM InverterIEEE Transactions on Industry Applications, 1981