Xu Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xu Peng has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Pengcheng Han
School of Power Electrical Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
5 shared publications - Shibin Gao
Southwest Jiaotong University
5 shared publications - Zeliang Shu
School of Electrical Engineering and the Key Laboratory of Magnetic Suspension Technology and Maglev Vehicle, Ministry of Education, Southwest Jiaotong University, Chengdu, China
5 shared publications - Xiaoqiong He
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
4 shared publications Chao Zhou
Institute of Aviation Electronic and Electrical Engineering, Civil Aviation Flight University of China, Chengdu, China
2 shared publications- Haijun Ren
Southwest Jiaotong University, 56711 Chengdu China
2 shared publications
Latest Publications
- Open Access
Design and Control of Range-Extender-Based Compound-Wing Unmanned VTOL
This paper proposes a power architecture for a Compound-Wing Unmanned VTOL to supply power during the hovering state. To enhance the hovering efficiency of the UAV while considering the cruising efficiency, the layout structure of a traditional Compound-Wing Unmanned VTOL is optimized. A high-power-density hybrid-power range-extender using an ICE (internal combustion engine) suitable for the Compound-Wing Unmanned VTOL is designed. The engine electronic control unit (ECU) suitable for the range-extender is presented by using a locally linearized state-space equation and LQR (Linear-Quadratic Regulator). Simulation experiments, ground running tests, and flight tests have been conducted to verify the performance of the Compound-Wing Unmanned VTOL and its power architecture.
Open AccessDesign and Control of Range-Extender-Based Compound-Wing Unmanned VTOL
This paper proposes a power architecture for a Compound-Wing Unmanned VTOL to supply power during the hovering state. To enhance the hovering efficiency of the UAV while considering the cruising efficiency, the layout structure of a traditional Compound-Wing Unmanned VTOL is optimized. A high-power-density hybrid-power range-extender using an ICE (internal combustion engine) suitable for the Compound-Wing Unmanned VTOL is designed. The engine electronic control unit (ECU) suitable for the range-extender is presented by using a locally linearized state-space equation and LQR (Linear-Quadratic Regulator). Simulation experiments, ground running tests, and flight tests have been conducted to verify the performance of the Compound-Wing Unmanned VTOL and its power architecture.
- Open Access
The Design of Improved Series Hybrid Power System Based on Compound-Wing VTOL
Hybrid power systems are now widely utilized in a variety of vehicle platforms due to their efficacy in reducing pollution and enhancing energy utilization efficiency. Nevertheless, the existing vehicle hybrid systems are of a considerable size and weight, rendering them unsuitable for integration into 25 kg compound-wing UAVs. This study presents a design solution for a compound-wing vertical takeoff and landing unmanned aerial vehicle (VTOL) equipped with an improved series hybrid power system. The system comprises a 48 V lithium polymer battery(Li-Po battery), a 60cc internal combustion engine (ICE), a converter, and a dedicated permanent magnet synchronous machine (PMSM) with four motors, which collectively facilitate dual-directional energy flow. The four motors serve as a load and lift assembly, providing the requisite lift during the take-off, landing, and hovering phases, and in the event of the ICE thrust insufficiency, as well as forward thrust during the level cruise phase by mounting the variable pitch propeller directly on the ICE. The entire hybrid power system of the UAV undergoes numerical modeling and experimental simulation to validate the feasibility of the complete hybrid power configuration. The validation is achieved by comparing and analyzing the results of the numerical simulations with ground tests. Moreover, the effectiveness of this hybrid power system is validated through the successful completion of flight test experiments. The hybrid power system has been demonstrated to significantly enhance the endurance of vertical flight for a compound-wing VTOL by more than 25 min, thereby establishing a solid foundation for future compound-wing VTOLs to enable multi-destination flights and multiple takeoffs and landings.
Open AccessThe Design of Improved Series Hybrid Power System Based on Compound-Wing VTOL
Hybrid power systems are now widely utilized in a variety of vehicle platforms due to their efficacy in reducing pollution and enhancing energy utilization efficiency. Nevertheless, the existing vehicle hybrid systems are of a considerable size and weight, rendering them unsuitable for integration into 25 kg compound-wing UAVs. This study presents a design solution for a compound-wing vertical takeoff and landing unmanned aerial vehicle (VTOL) equipped with an improved series hybrid power system. The system comprises a 48 V lithium polymer battery(Li-Po battery), a 60cc internal combustion engine (ICE), a converter, and a dedicated permanent magnet synchronous machine (PMSM) with four motors, which collectively facilitate dual-directional energy flow. The four motors serve as a load and lift assembly, providing the requisite lift during the take-off, landing, and hovering phases, and in the event of the ICE thrust insufficiency, as well as forward thrust during the level cruise phase by mounting the variable pitch propeller directly on the ICE. The entire hybrid power system of the UAV undergoes numerical modeling and experimental simulation to validate the feasibility of the complete hybrid power configuration. The validation is achieved by comparing and analyzing the results of the numerical simulations with ground tests. Moreover, the effectiveness of this hybrid power system is validated through the successful completion of flight test experiments. The hybrid power system has been demonstrated to significantly enhance the endurance of vertical flight for a compound-wing VTOL by more than 25 min, thereby establishing a solid foundation for future compound-wing VTOLs to enable multi-destination flights and multiple takeoffs and landings.
- 5 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 9 (2) , 2444-2452
A Hybrid Sensorless Starting Strategy for SRM With Fault-Tolerant Capability
The electromagnetic characteristics of the switched reluctance motors (SRM) appear highly nonlinear due to the high phase current in the starting stage. Thus, the key issue of developing a reliable sensorless starting strategy is to seek an effective way to avoid the saturation effects on position estimation. In this paper, a hybrid sensorless starting strategy with fault-tolerant capability is proposed. Firstly, an unsaturated inductance restructure based inductance vector coordinate transformation method (UIR-IVCT) is proposed for accurate initial positioning at standstill and continuous position estimation in the starting operation. Secondly, an incremental inductance partition method (IIP) with a bottom incremental inductance threshold is proposed for position pulse indirect measurement and fault-tolerant position estimation under phase lacking faults. These two methods are combined to ensure continuous position estimation under normal operation and fault-tolerant position estimation under one or two phases lacking cases. Thus, the proposed hybrid sensorless strategy can highly improve the overall reliability of the sensorless starting process. Furthermore, the proposed method is easy for implementation without complex initial data measurement, complicated parameter modeling, and heavy memory space. Detailed analysis and experimental results based on a 12/8 structure SRM prototype machine are provided for verification.
- 5 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 9 (2) , 2444-2452
A Hybrid Sensorless Starting Strategy for SRM With Fault-Tolerant Capability
The electromagnetic characteristics of the switched reluctance motors (SRM) appear highly nonlinear due to the high phase current in the starting stage. Thus, the key issue of developing a reliable sensorless starting strategy is to seek an effective way to avoid the saturation effects on position estimation. In this paper, a hybrid sensorless starting strategy with fault-tolerant capability is proposed. Firstly, an unsaturated inductance restructure based inductance vector coordinate transformation method (UIR-IVCT) is proposed for accurate initial positioning at standstill and continuous position estimation in the starting operation. Secondly, an incremental inductance partition method (IIP) with a bottom incremental inductance threshold is proposed for position pulse indirect measurement and fault-tolerant position estimation under phase lacking faults. These two methods are combined to ensure continuous position estimation under normal operation and fault-tolerant position estimation under one or two phases lacking cases. Thus, the proposed hybrid sensorless strategy can highly improve the overall reliability of the sensorless starting process. Furthermore, the proposed method is easy for implementation without complex initial data measurement, complicated parameter modeling, and heavy memory space. Detailed analysis and experimental results based on a 12/8 structure SRM prototype machine are provided for verification.
- 23 August 2022
- Published by Springer Nature in Journal of Power Electronics
- Vol. 22 (12) , 2025-2038
Negative sequence control for DC voltage balancing in three-phase cascaded H-bridge rectifiers considering DC-port failures
- 23 August 2022
- Published by Springer Nature in Journal of Power Electronics
- Vol. 22 (12) , 2025-2038
Negative sequence control for DC voltage balancing in three-phase cascaded H-bridge rectifiers considering DC-port failures
- 11 May 2022
- Published by Springer Nature in Journal of Power Electronics
- Vol. 22 (8) , 1242-1254
Voltage balance strategy for DC-port failures of three-phase cascaded H-bridge rectifiers based on negative sequence current injection
- 11 May 2022
- Published by Springer Nature in Journal of Power Electronics
- Vol. 22 (8) , 1242-1254
Voltage balance strategy for DC-port failures of three-phase cascaded H-bridge rectifiers based on negative sequence current injection
- Open Access
Voltage-Balancing Strategy for Three-Level Neutral-Point-Clamped Cascade Converter under Sequence Smooth Modulation
Three-level neutral-point clamped cascaded converters (3LNPC-CC) are widely used in high power nigh-voltage applications. This paper mainly discusses the open-circuit fault in DC-side of the 3LNPC-CC. Optimized by the sequence pulse modulation, a sequence smooth modulation (SSM) is proposed to keep the DC-side voltage balance while the 3LNPC-CC suffers open-circuit fault from DC-side. The SSM found efficient switch-state path through a 3-D cube model and simplified the path from thousands of switch state. The SSM avoids the complex calculation in the voltage-balancing modulation, while the dynamic character of it was less influenced. At the same time, the modulation changes the voltage level smoothly and balances the fault DC-side voltage effectively. The characters of the proposed modulation are verified by the simulation and the experiment.
Open AccessVoltage-Balancing Strategy for Three-Level Neutral-Point-Clamped Cascade Converter under Sequence Smooth Modulation
Three-level neutral-point clamped cascaded converters (3LNPC-CC) are widely used in high power nigh-voltage applications. This paper mainly discusses the open-circuit fault in DC-side of the 3LNPC-CC. Optimized by the sequence pulse modulation, a sequence smooth modulation (SSM) is proposed to keep the DC-side voltage balance while the 3LNPC-CC suffers open-circuit fault from DC-side. The SSM found efficient switch-state path through a 3-D cube model and simplified the path from thousands of switch state. The SSM avoids the complex calculation in the voltage-balancing modulation, while the dynamic character of it was less influenced. At the same time, the modulation changes the voltage level smoothly and balances the fault DC-side voltage effectively. The characters of the proposed modulation are verified by the simulation and the experiment.
- 2 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Fixed and Smooth-Switch-Sequence Modulation for Voltage Balancing Based on Single-Phase Three-Level Neutral Point Clamped Cascaded Rectifier
In this paper, a fixed and smooth-switch-sequence modulation (F-3SM) is proposed to equalize the dc-link voltages among the cascaded rectifier. The structure of a single-phase 3-level neutral point clamped cascaded rectifier (3LNPC-CR) is studied. Three core steps of this strategy are analyzed respectively, including carrier wave disposition calculation, fixed pulse generator, and voltage rank function. In addition, a criterion of the degree of the load unbalance is established in order to measure the voltage balancing boundary of the presented approach. The superiorities of the proposed control strategy embody the smooth switch sequence, the strong voltage balance capability, as well as the fixed switch sequence. Owe to these advantages, the cascaded rectifier could effectively reduce the switching frequency, achieve the goals of voltage balancing, and reduce the calculation burden of the controller when the number of cascaded modules is large. The effectiveness of the proposed strategy is verified by simulation and experiment results.
- 2 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Fixed and Smooth-Switch-Sequence Modulation for Voltage Balancing Based on Single-Phase Three-Level Neutral Point Clamped Cascaded Rectifier
In this paper, a fixed and smooth-switch-sequence modulation (F-3SM) is proposed to equalize the dc-link voltages among the cascaded rectifier. The structure of a single-phase 3-level neutral point clamped cascaded rectifier (3LNPC-CR) is studied. Three core steps of this strategy are analyzed respectively, including carrier wave disposition calculation, fixed pulse generator, and voltage rank function. In addition, a criterion of the degree of the load unbalance is established in order to measure the voltage balancing boundary of the presented approach. The superiorities of the proposed control strategy embody the smooth switch sequence, the strong voltage balance capability, as well as the fixed switch sequence. Owe to these advantages, the cascaded rectifier could effectively reduce the switching frequency, achieve the goals of voltage balancing, and reduce the calculation burden of the controller when the number of cascaded modules is large. The effectiveness of the proposed strategy is verified by simulation and experiment results.
- Open Access
Voltage-Balancing Strategy for Three-Level Neutral Point Clamped Cascade Converter under Sequence Pulse Modulation
In response to the unbalanced DC-port fault of three-level neutral point clamped cascaded converter (3LNPC-CC), a sequence pulse modulation (SPM) voltage-balancing strategy is proposed in this paper to balance DC-link voltage, not only within the module but also among modules. With the steps of carrier cascaded calculation and sequence pulse generator, the voltage level of cascaded modules would take a smooth transition. Then the limitation of the SPM strategy is calculated according to the law of volt-second balance and the law of energy conservation. The proposed strategy has the advantage of simple calculation and control stability. Simulation and experimental results show the superiority of the proposed strategy.
Open AccessVoltage-Balancing Strategy for Three-Level Neutral Point Clamped Cascade Converter under Sequence Pulse Modulation
In response to the unbalanced DC-port fault of three-level neutral point clamped cascaded converter (3LNPC-CC), a sequence pulse modulation (SPM) voltage-balancing strategy is proposed in this paper to balance DC-link voltage, not only within the module but also among modules. With the steps of carrier cascaded calculation and sequence pulse generator, the voltage level of cascaded modules would take a smooth transition. Then the limitation of the SPM strategy is calculated according to the law of volt-second balance and the law of energy conservation. The proposed strategy has the advantage of simple calculation and control stability. Simulation and experimental results show the superiority of the proposed strategy.
- 25 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Fault Diagnosis and System Reconfiguration Strategy of Single-phase Three Level Neutral-Point-Clamped Cascaded Inverter
This paper presents a fault diagnosis method and system reconfiguration strategy of three level neutral-pointclamped cascaded inverter (3L-NPC-CI) to enhance reliability of power supply in electrified railway. First, neural network is employed to perform open-circuit fault diagnosis and identify fault switches. Then, system reconfiguration strategy is proposed to perform single phase 3L-NPC-CI reconfiguration. Through the analysis of the operation status of 3L-NPC, there are eight fault modes in single bridge arm, including single-switch fault and double-switches fault. By the feature analysis for the output arm voltage harmonic of normal and eight fault modes, seven harmonic parameters are selected as fault feature vectors. Meanwhile, a three-layer neural network is constructed, and the seven feature vectors are the input layer of the neural network. By training algorithm, the fault switches location can be identified accurately about one modulation period. Then, the fault module is bypassed and the 3L-NPC-CI system is stable by reconfiguring the modulation strategy of other normal modular. Simulation and experimental results are given to validate the proposed fault diagnosis and system reconfiguration strategy. The proposed method is able to improve robustness and reliability of 3L-NPCCI in traction power supply system.
- 25 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Fault Diagnosis and System Reconfiguration Strategy of Single-phase Three Level Neutral-Point-Clamped Cascaded Inverter
This paper presents a fault diagnosis method and system reconfiguration strategy of three level neutral-pointclamped cascaded inverter (3L-NPC-CI) to enhance reliability of power supply in electrified railway. First, neural network is employed to perform open-circuit fault diagnosis and identify fault switches. Then, system reconfiguration strategy is proposed to perform single phase 3L-NPC-CI reconfiguration. Through the analysis of the operation status of 3L-NPC, there are eight fault modes in single bridge arm, including single-switch fault and double-switches fault. By the feature analysis for the output arm voltage harmonic of normal and eight fault modes, seven harmonic parameters are selected as fault feature vectors. Meanwhile, a three-layer neural network is constructed, and the seven feature vectors are the input layer of the neural network. By training algorithm, the fault switches location can be identified accurately about one modulation period. Then, the fault module is bypassed and the 3L-NPC-CI system is stable by reconfiguring the modulation strategy of other normal modular. Simulation and experimental results are given to validate the proposed fault diagnosis and system reconfiguration strategy. The proposed method is able to improve robustness and reliability of 3L-NPCCI in traction power supply system.
- Open Access
Harmonic Analysis of Single-Phase Neutral-Point-Clamped Cascaded Inverter in Advanced Traction Power Supply System Based on the Big Triangular Carrier Equivalence Method
An advanced traction power supply system based on a single phase neutral-point-clamped (NPC) cascaded inverter is studied. The big triangular carrier equivalence method in double coordinate system is proposed, which can reduce one coordinate system, thus simplifying the calculation. Based on the big triangular carrier equivalence method, the harmonic characteristics of a single phase NPC cascaded inverter are calculated by double Fourier transform and voltage harmonics expressions of 5-level, 9-level and 13-level output waveforms are derived. Finally, the performance and calculated results of the proposed method were verified by simulations and experiments. The result provides a theoretical basis for further studies on traction network resonance.
Open AccessHarmonic Analysis of Single-Phase Neutral-Point-Clamped Cascaded Inverter in Advanced Traction Power Supply System Based on the Big Triangular Carrier Equivalence Method
An advanced traction power supply system based on a single phase neutral-point-clamped (NPC) cascaded inverter is studied. The big triangular carrier equivalence method in double coordinate system is proposed, which can reduce one coordinate system, thus simplifying the calculation. Based on the big triangular carrier equivalence method, the harmonic characteristics of a single phase NPC cascaded inverter are calculated by double Fourier transform and voltage harmonics expressions of 5-level, 9-level and 13-level output waveforms are derived. Finally, the performance and calculated results of the proposed method were verified by simulations and experiments. The result provides a theoretical basis for further studies on traction network resonance.