Trans-venous lead removal without the use of extraction sheaths, results of >250 removal procedures
Open Access
- 27 August 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (1) , 112-116
Abstract
The number of implanted cardiac rhythm devices has rapidly increased in the past decade. Subsequently, the need for lead extraction has also increased. Several techniques of lead removal have been documented from manual traction of the lead to lead extraction assisted with mechanical or laser sheaths. The goal of this study was to review our experience with lead removal using manual traction without the assistance of extraction sheaths. In the Leiden University Medical Center all leads are removed using manual traction without the assistance of extraction sheaths. We have retrospectively reviewed all lead removal procedures performed between 2000 and 2009. Procedures were reviewed for indication, success, complication rates, and mortality. In total, 279 lead removal procedures were included. During these procedures 445 leads were removed. Time since lead implantation: 4.2 ± 4.7 years. During extraction 53(11.9%) leads fractured, of which >50% could still be completely removed using a femoral approach. A longer implantation duration [odds ratio (OR) 1.16 per year, 95% confidence interval (CI) 1.09–1.23] and passive fixation (OR 2.52, 95%CI 1.17–5.45) significantly associated with the chance of lead fracture during lead removal. Clinical success, using the primary approach of manual traction from the pectoral area, was obtained in 228 (84.8%) procedures. Major complications occurred in 2(0.7%) and minor in 13(4.7%) procedures. One patient died within 24 h after the procedure due to septic shock. There was no further mortality within the first month after the procedure. Lead removal using manual traction, without the assistance of lead extraction sheaths, is clinically successful in ∼85% of the lead extraction procedures. Concomitant morbidity and mortality are low. The highest clinical success (∼95%) was observed in patients with leads implanted less than 2.6 years.Keywords
This publication has 20 references indexed in Scilit:
- Implementation of Lead Safety RecommendationsPacing and Clinical Electrophysiology, 2010
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failureHeart Rhythm, 2009
- Extraction of Transvenous Pacing and ICD LeadsPacing and Clinical Electrophysiology, 2008
- Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trialEP Europace, 2007
- Implantable Cardioverter-DefibrillatorsJAMA, 2006
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureThe New England journal of medicine, 2005
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionThe New England journal of medicine, 2002
- Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial11No financial support was received for performing the procedures or collecting the data, or for data analysis.JACC, 1999
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaThe New England journal of medicine, 1996