Applying Standard Clinical Chemistry Assay Validation to Droplet Digital PCR Quantitative Liquid Biopsy Testing
Open Access
- 1 December 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 64 (12) , 1732-1742
Abstract
Background: Droplet digital PCR (ddPCR) is an emerging technology for quantitative cell-free DNA oncology applications. However, assay performance criteria must be established in a standardized manner to harness this potential. We reasoned that standard protocols used in clinical chemistry assay validation should be able to fill this need. Methods: We validated KRAS, EGFR, and BRAF quantitative ddPCR assays based on the Clinical Laboratory Improvement Act regulations for laboratory-developed tests in clinical chemistry and the matching Clinical and Laboratory Standards Institute guidelines. This included evaluation of limit of the blank (LOB), limit of detection (LOD), limit of quantification (LOQ), intraassay and interassay imprecision, analytical range, dilution linearity, accuracy (including comparison with orthogonal platforms), reference range study, interference, and stability studies. Results: For the ddPCR assays, the LOB was 4 mutant copies, LODs were 12 to 22 copies, and LOQs were 12 to 22 and 35 to 64 copies. The upper limit of the dynamic range was 30000 copies, and dilutions were linear down to the LOQs with good accuracy of spike recovery of Horizon reference material. Method comparisons with next-generation sequencing and an alternative ddPCR platform showed complete qualitative agreement and quantitative concordance, with slopes of 0.73 to 0.97 and R2s of 0.83 to 0.99. No substantial interferences were discovered. Wild-type copy numbers in plasma ranged from 462 to 6169/mL in healthy individuals. Conclusions: Standard clinical chemistry assay validation protocols can be applied to quantitative ddPCR assays. This should facilitate comparison of the performance of different assays and allow establishment of minimal significant change thresholds in monitoring applications.Keywords
This publication has 33 references indexed in Scilit:
- Next-generation sequencing and real-time quantitative PCR for minimal residual disease detection in B-cell disordersLeukemia, 2013
- Tolerance of Droplet-Digital PCR vs Real-Time Quantitative PCR to Inhibitory SubstancesClinical Chemistry, 2013
- Absolute quantification by droplet digital PCR versus analog real-time PCRNature Methods, 2013
- Comparative evaluation of published real-time PCR assays for the detection of malaria following MIQE guidelinesMalaria Journal, 2013
- The Digital MIQE Guidelines: Minimum Information for Publication of Quantitative Digital PCR ExperimentsClinical Chemistry, 2013
- Factors Contributing to Variability of Quantitative Viral PCR Results in Proficiency Testing Samples: a Multivariate AnalysisJournal of Clinical Microbiology, 2012
- Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number QuantificationAnalytical Chemistry, 2011
- Molecular diagnostics: harmonization through reference materials, documentary standards and proficiency testingExpert Review of Molecular Diagnostics, 2011
- Investigation of Reproducibility and Error Associated with qPCR Methods using Quantifiler® Duo DNA Quantification Kit*Journal of Forensic Sciences, 2010
- Differential susceptibility of PCR reactions to inhibitors: an important and unrecognised phenomenonBMC Research Notes, 2008