Rapid electrochemical platform for nicotine sensing in cigarettes and chewing gums
Open Access
- 1 October 2015
- journal article
- research article
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 8 (2) , 166-171
Abstract
A novel protocol for the simple and rapid determination of nicotine using square-wave voltammetry at boron-doped diamond electrode was developed. The effect of pH of supporting electrolyte, scan rate and square-wave voltammetric parameters was examined. Behavior study revealed that nicotine provided two irreversible oxidation peaks, the first one well-shaped at +1.14 V and the second one poorly-defined at +1.61 V vs. Ag/AgCl electrode in the presence of phosphate buffer (pH 9.0). Under optimal experimental conditions (modulation amplitude of 40 mV, frequency of 50 Hz and scan rate of 0.225 V · s-1), the current response of nicotine was proportionally linear in the concentration range from 9.9 × 10-6 to 1.7 × 10-4 mol · L-1 (R2 = 0.996) with the detection limit of 6.1 × 10-6 mol · L-1 (0.989 mg · L-1) and the relative standard deviation of 8.8 % (number of measurements n = 10, 5.7 × 10-5 mol · L-1 nicotine). The proposed procedure was applied to the quantification of nicotine in cigarettes and chewing gums with the determined values in good agreement with those declared by producer. In this respect, the developed protocol could represent an effective and rapid alternative to chemically modified electrodes in analysis of alkaloids.Keywords
This publication has 7 references indexed in Scilit:
- Electrochemical Behavior of Nicotine at Unmodified Carbon Paste Electrode and Its Determination in a Set of Refilling Liquids for Electronic CigarettesElectroanalysis, 2014
- An electrochemical method for high sensitive detection of nicotine and its interaction with bovine serum albuminElectrochemistry Communications, 2012
- Voltammetric Determination of Nicotine at Poly(4‐Amino‐3‐Hydroxynaphthalene Sulfonic Acid)‐Modified Glassy Carbon ElectrodeElectroanalysis, 2012
- Metallic Free Carbon Nanotube Cluster Modified Screen Printed Electrodes for the Sensing of Nicotine in Artificial SalivaElectroanalysis, 2009
- Electrochemical Behavior of Nicotine Studied by Voltammetric Techniques at Boron‐Doped Diamond ElectrodesAnalytical Letters, 2005
- Measuring tobacco smoke exposure: quantifying nicotine/cotinine concentration in biological samples by colorimetry, chromatography and immunoassay methodsJournal of Pharmaceutical and Biomedical Analysis, 2004
- DIRECT DETERMINATION OF NICOTINE IN ANTISMOKING PHARMACEUTICAL PRODUCTS AND IN TOBACCO USING AN INHIBITION BIOSENSORAnalytical Letters, 2001