KCKristína Cinková

Kristína Cinková

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kristína Cinková has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Ľubomír Švorc

    Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovak Republic

    4 shared publications
  • M. Marton

    Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Bratislava, Slovak Republic

    2 shared publications
  • Marian Vojs

    Faculty of Electrical Engineering and Information Technology, Institute of Electronics and Photonics, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19, Bratislava, Slovakia

    2 shared publications
  • A. Samphao

    Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, Thailand

    1 shared publication
  • Dalibor Stanković

    Faculty of Chemistry, University of Belgrade, Belgrade, Serbia

    1 shared publication
  • Dana Andrejčáková

    Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, SK-812 37 Bratislava, Slovak Republic

    1 shared publication

Latest Publications

  • The doping level of boron-doped diamond electrodes affects the voltammetric sensing of uric acid

    by K. Cinková, K. Kianičková, D. M. Stanković, M. Vojs, M. Marton, Ľ. Švorc

    In this work, the electrochemical oxidation and subsequent determination of uric acid was investigated using boron-doped diamond electrodes with various B/C ratios (0–2000 ppm). The cyclic voltammetric study showed one irreversible oxidation peak at +(1.1–1.25) V (vs. Ag/AgCl/3 M KCl) in the presence of Britton–Robinson buffer (pH 2.25) depending on the boron content. Employing differential pulse voltammetry using the 2000 ppm boron-doped diamond electrode the acquired analytical parameters were as follows: a limit of detection of 7.7 μM, a limit of quantification of 26 μM and intra-day repeatability (relative standard deviation of 2.9% for n = 15). After performing an interference study, the method was applied to the determination of uric acid in biological samples (human urine). The uric acid concentrations determined in the urine samples were compared with the reference values stated in the literature. The proposed methodology using boron-doped diamond electrodes could find applications in uric acid sensing within clinical, pharmaceutical and environmental analysis.


  • Open Access

    Electrochemical method for point-of-care determination of ciprofloxacin using boron-doped diamond electrode

    by Kristína Cinková, Dana Andrejčáková, Ľubomír Švorc

    This paper presents an electrochemical behavior study and quantification of fluoroquinolone antibiotic ciprofloxacin using boron-doped diamond electrode. Ciprofloxacin provides a diffusion-driven electrode reaction with an irreversible and poorly defined peak at +1.6 V vs. Ag/AgCl electrode in the presence of Britton-Robinson buffer solution pH 4. Applying differential pulse voltammetry (modulation amplitude of 60 mV, modulation time of 50 ms), the calibration curve with high linearity (R 2 = 0.997) was obtained within the concentration range of (0.74 – 20.0) × 10−6 mol L−1 with the detection limit of 6.0 × 10−7 mol L−1 and repeatability expressed by relative standard deviation of 2.7 % (for 20 measurements). Interference study was performed to explore the selectivity of the elaborated procedure. By analysis of pharmaceutical dosages and model human urine samples, the ciprofloxacin content with the recovery values ranging from 88.4 to 121.2 % were determined. The developed approach using point-of-care electrochemical sensor based on boron-doped diamond material could represent inexpensive analytical alternative to separation methods and could be beneficial in analysis of biological samples and in the quality control in pharmaceutical industry.


  • Open Access

    Rapid electrochemical platform for nicotine sensing in cigarettes and chewing gums

    by Kristína Cinková, Linda Dianová, Marian Vojs, Marián Marton, Ľubomír Švorc

    A novel protocol for the simple and rapid determination of nicotine using square-wave voltammetry at boron-doped diamond electrode was developed. The effect of pH of supporting electrolyte, scan rate and square-wave voltammetric parameters was examined. Behavior study revealed that nicotine provided two irreversible oxidation peaks, the first one well-shaped at +1.14 V and the second one poorly-defined at +1.61 V vs. Ag/AgCl electrode in the presence of phosphate buffer (pH 9.0). Under optimal experimental conditions (modulation amplitude of 40 mV, frequency of 50 Hz and scan rate of 0.225 V · s-1), the current response of nicotine was proportionally linear in the concentration range from 9.9 × 10-6 to 1.7 × 10-4 mol · L-1 (R2 = 0.996) with the detection limit of 6.1 × 10-6 mol · L-1 (0.989 mg · L-1) and the relative standard deviation of 8.8 % (number of measurements n = 10, 5.7 × 10-5 mol · L-1 nicotine). The proposed procedure was applied to the quantification of nicotine in cigarettes and chewing gums with the determined values in good agreement with those declared by producer. In this respect, the developed protocol could represent an effective and rapid alternative to chemically modified electrodes in analysis of alkaloids.


  • Electroanalytical application of a boron-doped diamond electrode for sensitive voltammetric determination of theophylline in pharmaceutical dosages and human urine

    by K. Cinková, N. Zbojeková, M. Vojs, M. Marton, A. Samphao, Ľ. Švorc

    In this paper, a novel voltammetric method for the determination of 1,3-dimethylxanthine alkaloid theophylline is elaborated using differential pulse (DPV) and square-wave voltammetric (SWV) modes on a boron-doped diamond electrode. Direct oxidation of the analyte at very positive potentials was observed by cyclic voltammetry, as evidenced by the presence of a well-shaped irreversible peak at +1.63 V (vs. Ag/AgCl electrode) in 1 mol L−1 sulphuric acid. After optimization of experimental conditions, the current response of theophylline was proportionally linear from 2 to 380 μmol L−1 using both pulse techniques. The developed electroanalytical method yielded low detection limits of 0.91 and 1.45 μmol L−1 associated with good intra-day repeatability (relative standard deviation of 3.2 and 2.5%) using DPV and SWV, respectively. The influence of some possible interferents was also evaluated. The practical feasibility of the proposed methodology was tested in the analysis of pharmaceutical dosages and human urine samples and good recovery values were accomplished (93.2–102.5%). The results of analysis of pharmaceuticals were also in close agreement at a 95% confidence level with those obtained using the titration (reference) method. Taking these attributes into consideration, the proposed sensor may be employed as a simple and effective analytical tool in drug control analysis and analysis of biological samples as well as a useful alternative to previously utilized modified electrodes in this field.