Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry
- 6 July 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (10) , 1343-1354
Abstract
Phosphorus is an element that is difficult to determine accurately by most analytical techniques. In particular, phosphorus determination by means of electrothermal atomic absorption spectrometry (ETAAS) has been traditionally hampered by (i) the practical inability of using phosphorus resonance lines; (ii) its complex chemical behaviour (e.g., formation of volatile compounds and a tendency to interact with graphite); and, particularly, (iii) the overlap observed between molecular and atomic phosphorus lines, which makes it very difficult to obtain reliable results when using line source-ETAAS. In this work, the potential of high resolution-continuum source ET spectrometry for the direct determination of phosphorus in biological solid samples is demonstrated. Two different methodologies, based on the monitoring of either atomic or molecular lines, were compared, paying special attention to the judicious selection of the chemical modifier and the temperature program that will be most adequate to the intended purpose. In order to enable atomic phosphorus monitoring, a high atomization temperature (2650 °C) and a combination of chemical modifiers consisting of palladium, ascorbic acid and tungsten (as permanent modifier) were used. On the other hand, when monitoring PO lines, tungsten coating and vaporization at only 1900 °C proved to be sufficient for attaining reliable results, although attention has to be paid to the possible effect of spectral interferences (e.g., NO lines). Both methods permitted the direct analysis of the samples under investigation, offering a high sample throughput (about 15–20 minutes per determination), good sensitivity (m0 around 5 ng and LODs at the µg g−1 level), RSD values in the 5–10% range, and straightforward calibration with aqueous standards.Keywords
This publication has 46 references indexed in Scilit:
- Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Management of severe hypophosphatemiaNutrition, 2009
- Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry—a critical review with focus on solid sampling and slurry analysisJournal of Analytical Atomic Spectrometry, 2008
- The concentrations of iron, calcium, zinc and phytate in cereals and legumes habitually consumed by infants living in East Lombok, IndonesiaJournal of Food Composition and Analysis, 2007
- Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometryAnalytical and Bioanalytical Chemistry, 2007
- Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissuesAnalytica Chimica Acta, 2007
- Determination of phosphorus by molecular absorption of phosphorus monoxide using a high-resolution continuum source absorption spectrometer and an air–acetylene flameJournal of Analytical Atomic Spectrometry, 2005
- Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of trace amounts of silicon in polyamide. Comparison of the performance of platinum and palladium as chemical modifiersSpectrochimica Acta Part B: Atomic Spectroscopy, 2004
- Direct solid sampling with electrothermal vaporization/atomization: what for and how?TrAC Trends in Analytical Chemistry, 2002
- The vaporization of phosphorus compounds and the use of chemical modifiers for the determination of phosphorus by electrothermal vaporization inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1997