Miguel A. Belarra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miguel A. Belarra has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Martín Resano
University of Zaragoza
22 shared publications - Juan Ramon Castillo
Analytical Spectroscopy and Sensors Group (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, 50009-Zaragoza, Spain
13 shared publications - Esperanza Garcia-Ruiz
Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain
7 shared publications - Cristina Crespo
Aragon Institute of Technology ITAINNOVA, Zaragoza, Spain
5 shared publications - Maite Aramendía
Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain
5 shared publications - Frank Vanhaecke
Atomic & Mass Spectrometry-A&MS Research Group, Department of Chemistry, Ghent University, Campus Sterre, Krijgslaan 281-S12, 9000 Ghent, Belgium
4 shared publications
Latest Publications
- 19 September 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (1) , 59-80
Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
After more than a decade since its commercial introduction, high-resolution continuum source atomic/molecular absorption spectrometry may be facing a mid-life crisis. Certainly, it is no longer a novel technique full of unknown potential, so it would already be time to establish the fields for which it is most suitable. This is, however, not so simple for a number of reasons. In the first place, more than a technique what we are discussing herein is a type of instrumentation with the potential to use two different techniques (atomic or molecular absorption), making it somewhat unique. Furthermore, the two techniques have not been explored equally, and more research on the mechanisms of formation of diatomic molecules is clearly needed. In the second place, new possibilities have recently appeared in the literature that need to be weighed as well. And there is the still unfulfilled, but nowadays more technically feasible than ever, promise to significantly increase the multi-elemental capabilities. This review critically examines the main research areas currently explored (namely, (i) direct analysis of solids and complex liquid materials, and (ii) determination of non-metals at trace levels via monitoring of molecular species) as well as the new venues (specifically, (i) isotopic analysis via monitoring of molecular species, and (ii) selective detection, quantification and sizing of nanoparticles) while also considering new instrumental developments, in an attempt to properly place high-resolution continuum source atomic/molecular absorption spectrometry in the field of trace element and isotopic analysis.
- 19 September 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (1) , 59-80
Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
After more than a decade since its commercial introduction, high-resolution continuum source atomic/molecular absorption spectrometry may be facing a mid-life crisis. Certainly, it is no longer a novel technique full of unknown potential, so it would already be time to establish the fields for which it is most suitable. This is, however, not so simple for a number of reasons. In the first place, more than a technique what we are discussing herein is a type of instrumentation with the potential to use two different techniques (atomic or molecular absorption), making it somewhat unique. Furthermore, the two techniques have not been explored equally, and more research on the mechanisms of formation of diatomic molecules is clearly needed. In the second place, new possibilities have recently appeared in the literature that need to be weighed as well. And there is the still unfulfilled, but nowadays more technically feasible than ever, promise to significantly increase the multi-elemental capabilities. This review critically examines the main research areas currently explored (namely, (i) direct analysis of solids and complex liquid materials, and (ii) determination of non-metals at trace levels via monitoring of molecular species) as well as the new venues (specifically, (i) isotopic analysis via monitoring of molecular species, and (ii) selective detection, quantification and sizing of nanoparticles) while also considering new instrumental developments, in an attempt to properly place high-resolution continuum source atomic/molecular absorption spectrometry in the field of trace element and isotopic analysis.
- 23 July 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (12) , 2229-2250
High-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of solid samples and complex materials: a tutorial review
This work tries to provide guidance for the development of new methods aiming at the direct analysis of solid samples or complex liquid materials using HR CS GFAAS.
- 23 July 2014
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (12) , 2229-2250
High-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of solid samples and complex materials: a tutorial review
This work tries to provide guidance for the development of new methods aiming at the direct analysis of solid samples or complex liquid materials using HR CS GFAAS.
- 18 December 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (5) , 1130-1139
Potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry to monitor the Ag body burden in individual Daphnia magna specimens exposed to Ag nanoparticles
This work evaluates the potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) for the direct determination of the Ag body burden in individual specimens of Daphnia magna (a small aquatic invertebrate of approx. 2 mm length typically used in ecotoxicological studies) exposed to different Ag species, and particularly to Ag nanoparticles (NPs). It is shown that this technique offers unique features for this type of application, permitting the direct analysis of these organisms in a very straightforward way (only approx. 2–3 min are required for the analysis of every individual) and constructing the calibration curve with aqueous standards. Moreover, appropriate selection of the detector pixels used for signal quantification makes it feasible to achieve a very broad linear range for any set of experimental conditions, contrary to what occurs for traditional line source-GFAAS. This feature is particularly important for this application, as every Daphnia magna specimen can be measured only once and its Ag content is not known in advance. In this case, the use of central and/or side pixels permits achieving a working range between 3 pg and 1 μg for the 328.068 nm Ag line, thus allowing analysis of all the samples of interest with the same experimental settings.
- 18 December 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (5) , 1130-1139
Potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry to monitor the Ag body burden in individual Daphnia magna specimens exposed to Ag nanoparticles
This work evaluates the potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) for the direct determination of the Ag body burden in individual specimens of Daphnia magna (a small aquatic invertebrate of approx. 2 mm length typically used in ecotoxicological studies) exposed to different Ag species, and particularly to Ag nanoparticles (NPs). It is shown that this technique offers unique features for this type of application, permitting the direct analysis of these organisms in a very straightforward way (only approx. 2–3 min are required for the analysis of every individual) and constructing the calibration curve with aqueous standards. Moreover, appropriate selection of the detector pixels used for signal quantification makes it feasible to achieve a very broad linear range for any set of experimental conditions, contrary to what occurs for traditional line source-GFAAS. This feature is particularly important for this application, as every Daphnia magna specimen can be measured only once and its Ag content is not known in advance. In this case, the use of central and/or side pixels permits achieving a working range between 3 pg and 1 μg for the 328.068 nm Ag line, thus allowing analysis of all the samples of interest with the same experimental settings.
- 1 May 2012
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 71-72, 24-30
Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry
- 1 May 2012
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 71-72, 24-30
Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry
- 2 March 2012
- Published by Wiley
- p. 199-219
Green Analytical Atomic Spectrometry
- 15 October 2010
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (12) , 1864-1873
Solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry to monitor the biodistribution of gold nanoparticles in mice tissue after intravenous administration
In this work, the capabilities of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (GFAAS) for the direct determination of the Au content in different body compartments of mice that were previously exposed to Au nanoparticles (AuNP) capped with different compounds have been investigated. It was concluded that this technique offers interesting features for this type of application, permitting the fast (approx. 15 min per sample) and simple analysis of these materials with minimal sample pretreatment, ensuring a similar analytical response regardless of the functionalizing compound chosen for the NP. The potential of this technique for resolving spectral overlaps with PO molecular lines is shown to be essential to ensure interference-free results for those samples containing only a few tens of ng g−1 of Au (brain tissues), such that accurate results can be obtained using straightforward calibration against aqueous standards even in circumstances that would be very unfavorable for traditional line source GFAAS instrumentation. A detection limit of 5 pg (2 ng g−1) is reported. The usefulness of the method proposed to obtain meaningful conclusions regarding i) the temporal biodistribution of small (approx. 2 nm in diameter) AuNP in mouse organs, and ii) the different behavior observed depending upon the functionalizing compound used (glucose or lactose) is also demonstrated.
- 15 October 2010
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (12) , 1864-1873
Solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry to monitor the biodistribution of gold nanoparticles in mice tissue after intravenous administration
In this work, the capabilities of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (GFAAS) for the direct determination of the Au content in different body compartments of mice that were previously exposed to Au nanoparticles (AuNP) capped with different compounds have been investigated. It was concluded that this technique offers interesting features for this type of application, permitting the fast (approx. 15 min per sample) and simple analysis of these materials with minimal sample pretreatment, ensuring a similar analytical response regardless of the functionalizing compound chosen for the NP. The potential of this technique for resolving spectral overlaps with PO molecular lines is shown to be essential to ensure interference-free results for those samples containing only a few tens of ng g−1 of Au (brain tissues), such that accurate results can be obtained using straightforward calibration against aqueous standards even in circumstances that would be very unfavorable for traditional line source GFAAS instrumentation. A detection limit of 5 pg (2 ng g−1) is reported. The usefulness of the method proposed to obtain meaningful conclusions regarding i) the temporal biodistribution of small (approx. 2 nm in diameter) AuNP in mouse organs, and ii) the different behavior observed depending upon the functionalizing compound used (glucose or lactose) is also demonstrated.
- 6 July 2009
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (10) , 1343-1354
Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry
Phosphorus is an element that is difficult to determine accurately by most analytical techniques. In particular, phosphorus determination by means of electrothermal atomic absorption spectrometry (ETAAS) has been traditionally hampered by (i) the practical inability of using phosphorus resonance lines; (ii) its complex chemical behaviour (e.g., formation of volatile compounds and a tendency to interact with graphite); and, particularly, (iii) the overlap observed between molecular and atomic phosphorus lines, which makes it very difficult to obtain reliable results when using line source-ETAAS. In this work, the potential of high resolution-continuum source ET spectrometry for the direct determination of phosphorus in biological solid samples is demonstrated. Two different methodologies, based on the monitoring of either atomic or molecular lines, were compared, paying special attention to the judicious selection of the chemical modifier and the temperature program that will be most adequate to the intended purpose. In order to enable atomic phosphorus monitoring, a high atomization temperature (2650 °C) and a combination of chemical modifiers consisting of palladium, ascorbic acid and tungsten (as permanent modifier) were used. On the other hand, when monitoring PO lines, tungsten coating and vaporization at only 1900 °C proved to be sufficient for attaining reliable results, although attention has to be paid to the possible effect of spectral interferences (e.g., NO lines). Both methods permitted the direct analysis of the samples under investigation, offering a high sample throughput (about 15–20 minutes per determination), good sensitivity (m0 around 5 ng and LODs at the µg g−1 level), RSD values in the 5–10% range, and straightforward calibration with aqueous standards.
- 6 July 2009
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (10) , 1343-1354
Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry
Phosphorus is an element that is difficult to determine accurately by most analytical techniques. In particular, phosphorus determination by means of electrothermal atomic absorption spectrometry (ETAAS) has been traditionally hampered by (i) the practical inability of using phosphorus resonance lines; (ii) its complex chemical behaviour (e.g., formation of volatile compounds and a tendency to interact with graphite); and, particularly, (iii) the overlap observed between molecular and atomic phosphorus lines, which makes it very difficult to obtain reliable results when using line source-ETAAS. In this work, the potential of high resolution-continuum source ET spectrometry for the direct determination of phosphorus in biological solid samples is demonstrated. Two different methodologies, based on the monitoring of either atomic or molecular lines, were compared, paying special attention to the judicious selection of the chemical modifier and the temperature program that will be most adequate to the intended purpose. In order to enable atomic phosphorus monitoring, a high atomization temperature (2650 °C) and a combination of chemical modifiers consisting of palladium, ascorbic acid and tungsten (as permanent modifier) were used. On the other hand, when monitoring PO lines, tungsten coating and vaporization at only 1900 °C proved to be sufficient for attaining reliable results, although attention has to be paid to the possible effect of spectral interferences (e.g., NO lines). Both methods permitted the direct analysis of the samples under investigation, offering a high sample throughput (about 15–20 minutes per determination), good sensitivity (m0 around 5 ng and LODs at the µg g−1 level), RSD values in the 5–10% range, and straightforward calibration with aqueous standards.
- 1 June 2009
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 64 (6) , 520-529
Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry
- 1 June 2009
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 64 (6) , 520-529
Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry