The vascular connector, design of a new device for sutureless vascular anastomosis
Open Access
- 22 November 2014
- journal article
- research article
- Published by Springer Nature in Annals of Surgical Innovation and Research
- Vol. 8 (1) , 8
Abstract
In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. The new vascular connector (NVC) is a hypothetical design of a vascular device, proposed for creation and maintenance of sutureless vascular anastomosis. Implication of NVC would introduce a new device and technique in establishment of sutureless vascular anastomosis in which surgical approach is minimized and so post-operation disorders. It would eliminate need for suture; shorten clampage and operation time, consequently reducing stress for both, the surgeon and the patient. It enables the creation of vascular anastomosis fast, simple, safe, reliable, with satisfactory patency and stability of anastomosis. Efficacy of NVC needs to be evaluated in further studies, in order to be confirmed for clinical use. The effectiveness of NVC should be verified firstly in vitro and in vivo tests; and by animal experiments. The likelihood of its negative influence in thrombogenicity should be well evaluated. Implication of the new vascular connector (NVC) would be of interest to both patients and the surgeon due to the following main achievements: 1) enables the creation of vascular anastomosis fast and simple, 2) significant shortening of clampage time of blood vessels and operation time-this assumption would be followed by reduced risk of operative and post-operative complications and length of hospital stay or admission to Intensive care unit, 3) safe and reliable, 4) compatible with any blood vessel and standard vascular graft, 5) using the NVC we will reduce in minimum need for replaced blood volume, 6) reduces the cost of treatment. It is anticipated that the NVC would provide shorter operation time and least operative and post-operative complications in creation of sutureless vascular anastomosis.Keywords
This publication has 21 references indexed in Scilit:
- Use of a Novel Penetrating, Sutureless Anastomotic Device in Arterial Microvascular AnastomosesJournal of Reconstructive Microsurgery, 2008
- Sutureless anastomoses of rabbit carotid arteries with BioGlueThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Vein graft anastomoses with magnetsJournal of Plastic, Reconstructive & Aesthetic Surgery, 2007
- The Vascular Join: a new sutureless anastomotic device to perform end-to-end anastomosis. Preliminary results in an animal modelInteractive CardioVascular and Thoracic Surgery, 2006
- Synthesis of biocompatible segmented polyurethanes from aliphatic diisocyanates and diurea diol chain extendersActa Biomaterialia, 2005
- A new mechanical connector for distal coronary artery anastomoses in coronary artery bypass grafting: A randomized, controlled studyThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Side-to-side sutureless vascular anastomosis with magnetsJournal of Vascular Surgery, 2004
- Four-year surveillance study of metal clip anastomoses in peripheral arterial reconstructionInternational Journal of Angiology, 2004
- Clinical experience with devices for facilitated anastomoses in coronary artery bypass surgeryThe Annals of Thoracic Surgery, 2004
- Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses?The Annals of Thoracic Surgery, 2001