Lulzim Vokrri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lulzim Vokrri has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Nexhmi Hyseni
Department of Surgery, University Clinical Center of Kosovo, Prishtina, Republic of Kosovo
2 shared publications Philippe Cinquin
University of Grenoble Alpes/CNRS/TIMC-IMAG UMR 5525 (GMCAO team), Grenoble, France
2 shared publicationsArsim Qavdarbasha
Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo ; Medical Faculty, University of Pristina, Republic of Kosovo ; Veterinary Institute, Pristina, Republic of Kosovo
1 shared publication- Arsim Qavdarbasha
Department of Vascular Surgery, University Clinical Center of Kosovo, Medical Faculty of the University of Pristina, Boulevard "Dëshmoret e Kombit" nn; 10000, Pristina, Republic of Kosovo
1 shared publication Carmine Sessa
Department of Vascular Surgery, University Clinical Center of Grenoble, Grenoble, 38000, France ; University of Grenoble Alpes, Grenoble 38000, France
1 shared publication- Carmine Sessa
Department of Vascular and Thoracic Surgery, University Hospital Centre of Grenoble; Faculté de Médecine, 38706 La Tronche Cedex, France
1 shared publication
Latest Publications
- 18 September 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 66 (6) , 884
The Future of Sutureless Vascular Anastomoses Using the New Vascular Connector
- 18 September 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 66 (6) , 884
The Future of Sutureless Vascular Anastomoses Using the New Vascular Connector
- Open Access
- 1 March 2015
- Published by Taylor & Francis in Vascular Health and Risk Management
- Vol. 11, 211-217
Experimental study of sutureless vascular anastomosis with use of glued prosthesis in rabbits
Objective: The objective of this study is to explore the feasibility and efficacy of a new technique for sutureless vascular anastomosis, using glued prosthesis, as a sole anastomosis fixation method in rabbits. Methods: Ten rabbits were randomly selected to conduct the experiment. Five rabbits underwent direct anastomosis of infrarenal abdominal aorta, with glued prosthesis. In five other rabbits, reconstruction was done by sutured anastomosis. All animals were immediately examined by echo-Doppler for patency of anastomosis. The burst pressure of the glued anastomosis was measured and compared with that of a sutured artery. The animals were euthanized, and tissue samples were taken for histological examination immediately after the experiment. Results: Compared to conventional anastomoses, sutureless vascular anastomoses required shorter time of creation and significantly reduced blood loss (P Conclusion: This technique may provide a feasible and successful alternative in vascular surgery. However, further long-term studies are necessary to elucidate the break pressure and degree of inflammation at the anastomotic site.
- 1 March 2015
- Published by Taylor & Francis in Vascular Health and Risk Management
- Vol. 11, 211-217
Open AccessExperimental study of sutureless vascular anastomosis with use of glued prosthesis in rabbits
Objective: The objective of this study is to explore the feasibility and efficacy of a new technique for sutureless vascular anastomosis, using glued prosthesis, as a sole anastomosis fixation method in rabbits. Methods: Ten rabbits were randomly selected to conduct the experiment. Five rabbits underwent direct anastomosis of infrarenal abdominal aorta, with glued prosthesis. In five other rabbits, reconstruction was done by sutured anastomosis. All animals were immediately examined by echo-Doppler for patency of anastomosis. The burst pressure of the glued anastomosis was measured and compared with that of a sutured artery. The animals were euthanized, and tissue samples were taken for histological examination immediately after the experiment. Results: Compared to conventional anastomoses, sutureless vascular anastomoses required shorter time of creation and significantly reduced blood loss (P Conclusion: This technique may provide a feasible and successful alternative in vascular surgery. However, further long-term studies are necessary to elucidate the break pressure and degree of inflammation at the anastomotic site.
- Open Access
- 22 November 2014
- Published by Springer Nature in Annals of Surgical Innovation and Research
- Vol. 8 (1) , 8
The vascular connector, design of a new device for sutureless vascular anastomosis
In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. The new vascular connector (NVC) is a hypothetical design of a vascular device, proposed for creation and maintenance of sutureless vascular anastomosis. Implication of NVC would introduce a new device and technique in establishment of sutureless vascular anastomosis in which surgical approach is minimized and so post-operation disorders. It would eliminate need for suture; shorten clampage and operation time, consequently reducing stress for both, the surgeon and the patient. It enables the creation of vascular anastomosis fast, simple, safe, reliable, with satisfactory patency and stability of anastomosis. Efficacy of NVC needs to be evaluated in further studies, in order to be confirmed for clinical use. The effectiveness of NVC should be verified firstly in vitro and in vivo tests; and by animal experiments. The likelihood of its negative influence in thrombogenicity should be well evaluated. Implication of the new vascular connector (NVC) would be of interest to both patients and the surgeon due to the following main achievements: 1) enables the creation of vascular anastomosis fast and simple, 2) significant shortening of clampage time of blood vessels and operation time-this assumption would be followed by reduced risk of operative and post-operative complications and length of hospital stay or admission to Intensive care unit, 3) safe and reliable, 4) compatible with any blood vessel and standard vascular graft, 5) using the NVC we will reduce in minimum need for replaced blood volume, 6) reduces the cost of treatment. It is anticipated that the NVC would provide shorter operation time and least operative and post-operative complications in creation of sutureless vascular anastomosis.
- 22 November 2014
- Published by Springer Nature in Annals of Surgical Innovation and Research
- Vol. 8 (1) , 8
Open AccessThe vascular connector, design of a new device for sutureless vascular anastomosis
In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. The new vascular connector (NVC) is a hypothetical design of a vascular device, proposed for creation and maintenance of sutureless vascular anastomosis. Implication of NVC would introduce a new device and technique in establishment of sutureless vascular anastomosis in which surgical approach is minimized and so post-operation disorders. It would eliminate need for suture; shorten clampage and operation time, consequently reducing stress for both, the surgeon and the patient. It enables the creation of vascular anastomosis fast, simple, safe, reliable, with satisfactory patency and stability of anastomosis. Efficacy of NVC needs to be evaluated in further studies, in order to be confirmed for clinical use. The effectiveness of NVC should be verified firstly in vitro and in vivo tests; and by animal experiments. The likelihood of its negative influence in thrombogenicity should be well evaluated. Implication of the new vascular connector (NVC) would be of interest to both patients and the surgeon due to the following main achievements: 1) enables the creation of vascular anastomosis fast and simple, 2) significant shortening of clampage time of blood vessels and operation time-this assumption would be followed by reduced risk of operative and post-operative complications and length of hospital stay or admission to Intensive care unit, 3) safe and reliable, 4) compatible with any blood vessel and standard vascular graft, 5) using the NVC we will reduce in minimum need for replaced blood volume, 6) reduces the cost of treatment. It is anticipated that the NVC would provide shorter operation time and least operative and post-operative complications in creation of sutureless vascular anastomosis.