LVAD Pump Flow Does Not Adequately Increase With Exercise
Open Access
- 28 August 2018
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 43 (3) , 222-228
Abstract
Left ventricular assist devices (LVADs) restore cardiovascular circulatory demand at rest with a spontaneous increase in pump flow to exercise. The relevant contribution of cardiac output provided by the LVAD and ejected through the aortic valve for exercises of different intensities has been barely investigated in patients. The hypothesis of this study was that different responses in continuous recorded pump parameters occur for maximal and submaximal intensity exercises and that the pump flow change has an impact on the oxygen uptake at peak exercise (pVO2). Cardiac and pump parameters such as LVAD flow rate (QLVAD), heart rate (HR), and aortic valve (AV) opening were analyzed from continuously recorded LVAD data during physical exercises of maximal (bicycle ergometer test) and submaximal intensities (6‐min walk test and regular trainings). During all exercise sessions, the LVAD speed was kept constant. Cardiac and pump parameter responses of 16 patients for maximal and submaximal intensity exercises were similar for QLVAD: +0.89 ± 0.52 versus +0.59 ± 0.38 L/min (P = 0.07) and different for HR: +20.4 ± 15.4 versus +7.7 ± 5.8 bpm (P < 0.0001) and AV‐opening with 71% versus 23% of patients (P < 0.0001). Multi‐regression analysis with pVO2 (R2 = 0.77) showed relation to workload normalized by bodyweight (P = 0.0002), HR response (P = 0.001), AV‐opening (P = 0.02), and age (P = 0.06) whereas the change in QLVAD was irrelevant. Constant speed LVADs provide inadequate support for maximum intensity exercises. AV‐opening and improvements in HR show an important role for higher exercise capacities and reflect exercise intensities. Changes in pump flow do not impact pVO2 and are independent of AV‐opening and response in HR. An LVAD speed control may lead to adequate left ventricular support during strenuous physical activities.Keywords
Funding Information
- Austrian Science Fund (KLI357)
This publication has 32 references indexed in Scilit:
- Continuous Monitoring of Cardiac Rhythms in Left Ventricular Assist Device PatientsArtificial Organs, 2013
- Axial and centrifugal continuous-flow rotary pumps: A translation from pump mechanics to clinical practiceThe Journal of Heart and Lung Transplantation, 2013
- Development of a Pump Flow Estimator for Rotary Blood Pumps to Enhance Monitoring of Ventricular FunctionArtificial Organs, 2012
- Relationship Between Pump Speed and Exercise Capacity During HeartMate II Left Ventricular Assist Device Support: Influence of Residual Left Ventricular FunctionEuropean Journal of Heart Failure, 2012
- Exercise Capacity in Patients Supported With Rotary Blood Pumps Is Improved by a Spontaneous Increase of Pump Flow at Constant Pump Speed and by a Rise in Native Cardiac OutputArtificial Organs, 2011
- Continuous Flow Left Ventricular Assist Device Improves Functional Capacity and Quality of Life of Advanced Heart Failure PatientsJACC, 2010
- Assessment of Arterial Blood Pressure During Support With an Axial Flow Left Ventricular Assist DeviceThe Journal of Heart and Lung Transplantation, 2009
- Hemodynamic and Exercise Performance With Pulsatile and Continuous-Flow Left Ventricular Assist DevicesCirculation, 2007
- Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates☆European Journal of Cardio-Thoracic Surgery, 2005
- Reference Equations for the Six-Minute Walk in Healthy AdultsAmerican Journal of Respiratory and Critical Care Medicine, 1998