Computational modeling of neuromuscular activation by transcutaneous electrical nerve stimulation to the lower back
- 21 March 2025
- journal article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035004
Abstract
Objectives. Transcutaneous Electrical Nerve Stimulation (TENS) to the lower back is an established electrical therapy for acute and chronic back pain. The efficacy and mechanisms of lower back TENS depend on the penetration depth of electrical current. We compare the intensity and spatial extent (depth) of current flow in the body during TENS with varied electrode positions/shapes on the human back. Materials and Methods. A high-resolution MRI-derived anatomical model of the back was developed, considering major tissue compartments, including skin and muscles. TENS with upper and lower back electrode positions and varied electrode shapes (square, circular, rectangular) were simulated. An exemplary 50 mA current was applied under quasistatic approximation and quasi-uniform electric field assumption of 6.15 V m−1 (low), 12.3 V m−1 (mid), and 24.6 V m−1 (high) neuromuscular activation thresholds were considered. Results. Under all simulated TENS conditions (50 mA), electric fields at the skin exceed the high threshold (consistent with peripheral nerve activation) and at least some muscle regions exceed the mid threshold. Muscle activation was influenced by the anatomy of muscle in the medial-lateral direction and upper-lower back. The electrode shape had minimal effect on deep tissue current penetration. Conclusions. Our simulations indicate significant current penetration into back tissue (electric fields above low threshold) to >8 cm in all TENS conditions simulated, consistent with nerve and muscle activation. Significance. Anatomically precise models of upper and lower back TENS show current penetration to deep muscle, supporting direct muscle stimulation driving clinical benefits.Keywords
Funding Information
- NIMH (1R01MH111896)
- NINDS (1R01NS 101362)
- NIH (R01 MH112737)
- NCI (1R01NS 112996-01A1)
- New York State Department of Health (DOH01-C31291GG)
This publication has 61 references indexed in Scilit:
- Adaptive current tDCS up to 4 mABrain Stimulation, 2020
- Modeling sequence and quasi-uniform assumption in computational neurostimulation2015
- The “Quasi-Uniform” Assumption in Animal and Computational Models of Non-Invasive Electrical StimulationBrain Stimulation, 2013
- Spinal cord direct current stimulation: finite element analysis of the electric field and current densityMedical & Biological Engineering & Computing, 2011
- Gyri-precise head model of transcranial direct current stimulation: Improved spatial focality using a ring electrode versus conventional rectangular padBrain Stimulation, 2009
- A model for transcutaneous current stimulation: simulations and experimentsMedical & Biological Engineering & Computing, 2008
- Recent advances in research relevant to electric and magnetic field exposure guidelinesBioelectromagnetics, 2008
- Biological effects from electromagnetic field exposure and public exposure standardsBiomedicine & Pharmacotherapy, 2008
- Release of GABA and activation of GABAA in the spinal cord mediates the effects of TENS in ratsBrain Research, 2007
- Effect of electric field induced transmembrane potential on spheroidal cells: theory and experimentEuropean Biophysics Journal, 2003