Marom Bikson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marom Bikson has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Niranjan Khadka
Research and Development, Soterix Medical Inc., Woodbridge, NJ, USA
4 shared publications - Abhishek Datta
Research and Development, Soterix Medical Inc., Woodbridge, NJ, USA
2 shared publications - Angel V. Peterchev
Duke University
2 shared publications - Boshuo Wang
Duke University
2 shared publications - Denys Nikolayev
CNRS, IETRUMR 6164, University of Rennes, Rennes, France
2 shared publications - Gabriel Gaugain
EWAVES, IETR, 263, avenue du Général Leclerc, Rennes, 35042, FRANCE
2 shared publications
Latest Publications
- 1 August 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045066
Morphological bias of the MNI152 brain
The MNI152 template is widely treated as a representative average brain in neuroimaging, computational modeling, and neuromodulation research, yet its fidelity to true population morphology has not been systematically evaluated. In this study, we compared the MNI152 template to 430 individual MRI scans from a publicly available dataset spanning Asian, Black, and White participants. We additionally compared the MNI152 template with the independently developed US200 template, which was generated using a modern diffeomorphic template-building framework, to assess whether a contemporary template better represents human brain morphology. We conducted affine registrations and deformation-based morphometry to detect and quantify gross morphological differences as well as local voxel-level deformations. The MNI152 template consistently required consistent global contraction, and its Jacobian fields revealed spatially heterogeneous deformations, indicating systematic mismatches in both size and shape. In contrast, the US200 template showed mean scaling and deformation values near 1.0, reflecting closer correspondence to real human anatomy. These findings suggest that the MNI152 template is less representative of the morphology of this study population than the US200 template and that linear registration alone cannot eliminate these systematic differences. Reliance on MNI152 may therefore introduce anatomical bias in applications requiring high morphological fidelity. These results further support continued development of modern, unbiased, and potentially demographic-specific templates.
- 1 August 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045066
Morphological bias of the MNI152 brain
The MNI152 template is widely treated as a representative average brain in neuroimaging, computational modeling, and neuromodulation research, yet its fidelity to true population morphology has not been systematically evaluated. In this study, we compared the MNI152 template to 430 individual MRI scans from a publicly available dataset spanning Asian, Black, and White participants. We additionally compared the MNI152 template with the independently developed US200 template, which was generated using a modern diffeomorphic template-building framework, to assess whether a contemporary template better represents human brain morphology. We conducted affine registrations and deformation-based morphometry to detect and quantify gross morphological differences as well as local voxel-level deformations. The MNI152 template consistently required consistent global contraction, and its Jacobian fields revealed spatially heterogeneous deformations, indicating systematic mismatches in both size and shape. In contrast, the US200 template showed mean scaling and deformation values near 1.0, reflecting closer correspondence to real human anatomy. These findings suggest that the MNI152 template is less representative of the morphology of this study population than the US200 template and that linear registration alone cannot eliminate these systematic differences. Reliance on MNI152 may therefore introduce anatomical bias in applications requiring high morphological fidelity. These results further support continued development of modern, unbiased, and potentially demographic-specific templates.
- Open Access
Neuronavigation-free and MRI-free Localization of Deep Brain Targets
Emerging non-invasive brain stimulation modalities, including transcranial focused ultrasound and transcranial interferential stimulation, offer the promise of safely and non-invasively modulating deep brain structures. Accurate targeting of these regions typically involves subject-specific MRI, limiting widespread deployment. Here, we introduce an MRI-free, neuronavigation-free method for localizing deep brain targets using only three simple scalp measurements. These measures define an affine transformation that maps the MNI152 standard head model to an individual’s head geometry. We evaluated our approach on 50 healthy adults, comparing our model◻predicted coordinates against ground-truth coordinates obtained via MRI-based nonlinear normalization. Across ten deep brain targets, our method achieved a mean localization error of 3.82 mm demonstrating a more accessible and cost-efficient alternative than MRI- or neuronavigation-based approaches.
Open AccessNeuronavigation-free and MRI-free Localization of Deep Brain Targets
Emerging non-invasive brain stimulation modalities, including transcranial focused ultrasound and transcranial interferential stimulation, offer the promise of safely and non-invasively modulating deep brain structures. Accurate targeting of these regions typically involves subject-specific MRI, limiting widespread deployment. Here, we introduce an MRI-free, neuronavigation-free method for localizing deep brain targets using only three simple scalp measurements. These measures define an affine transformation that maps the MNI152 standard head model to an individual’s head geometry. We evaluated our approach on 50 healthy adults, comparing our model◻predicted coordinates against ground-truth coordinates obtained via MRI-based nonlinear normalization. Across ten deep brain targets, our method achieved a mean localization error of 3.82 mm demonstrating a more accessible and cost-efficient alternative than MRI- or neuronavigation-based approaches.
- Open Access
- 23 October 2025
- Published by Escola Bahiana de Medicina e Saude Publica in Brain Imaging and Stimulation
- Vol. 4, e6265
Prefrontal coherence in the delta, theta, alpha, and beta frequency bands in response to cathodic high-definition transcranial direct current stimulation in professional basketball players during preparation for free-throw shooting bouts
INTRODUCTION: Cathodic high-definition transcranial direct current stimulation (HD-tDCS has been shown to modulate cerebral activity. OBJECTIVES: This study examined if cathodic high-definition transcranial direct current stimulation (HD-tDCS) could modulate cortical coherence during the preparation for free-throw shooting in professional female basketball players. METHODS AND MATERIALS: The cortical activity was measured using electroencephalography (EEG) and the spectral bands δ (0.5–≤4 Hz), theta θ (>4–≤8 Hz), alpha α (>8–≤13 Hz), and beta β (>13–≤30 Hz) were analyzed. Only successful free throws (n = 1,893) were considered. Multi-channel HD-tDCS (cathodic and sham) was applied for 20 minutes prior to bouts of shooting. RESULTS AND CONCLUSION: For FP1-F3 (channels) coherence, there was an interaction effect for delta (F = 5.93; p = 0.03), theta (F = 11.38; p = 0.008), alpha (F = 15.33; p = 0.004), but not for beta band (F = 0.875; p = 0.37). The post-hoc analysis revealed significant differences between post-cathodic HD-tDCS and pre-cathodic HD-tDCS, and post-cathodic HD-tDCS and post-sham HD-tDCS. These differences were due to increases in these spectral bands’ coherence following the cathodic stimulation. No changes or differences in coherence were observed for other pairs of channels regardless of the HD-tDCS condition. These findings suggest that the effects are relatively focal, inducing changes primarily in the left pre-frontal hemisphere while preserving inter-hemispheric connectivity.
- 23 October 2025
- Published by Escola Bahiana de Medicina e Saude Publica in Brain Imaging and Stimulation
- Vol. 4, e6265
Open AccessPrefrontal coherence in the delta, theta, alpha, and beta frequency bands in response to cathodic high-definition transcranial direct current stimulation in professional basketball players during preparation for free-throw shooting bouts
INTRODUCTION: Cathodic high-definition transcranial direct current stimulation (HD-tDCS has been shown to modulate cerebral activity. OBJECTIVES: This study examined if cathodic high-definition transcranial direct current stimulation (HD-tDCS) could modulate cortical coherence during the preparation for free-throw shooting in professional female basketball players. METHODS AND MATERIALS: The cortical activity was measured using electroencephalography (EEG) and the spectral bands δ (0.5–≤4 Hz), theta θ (>4–≤8 Hz), alpha α (>8–≤13 Hz), and beta β (>13–≤30 Hz) were analyzed. Only successful free throws (n = 1,893) were considered. Multi-channel HD-tDCS (cathodic and sham) was applied for 20 minutes prior to bouts of shooting. RESULTS AND CONCLUSION: For FP1-F3 (channels) coherence, there was an interaction effect for delta (F = 5.93; p = 0.03), theta (F = 11.38; p = 0.008), alpha (F = 15.33; p = 0.004), but not for beta band (F = 0.875; p = 0.37). The post-hoc analysis revealed significant differences between post-cathodic HD-tDCS and pre-cathodic HD-tDCS, and post-cathodic HD-tDCS and post-sham HD-tDCS. These differences were due to increases in these spectral bands’ coherence following the cathodic stimulation. No changes or differences in coherence were observed for other pairs of channels regardless of the HD-tDCS condition. These findings suggest that the effects are relatively focal, inducing changes primarily in the left pre-frontal hemisphere while preserving inter-hemispheric connectivity.
- 27 May 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (3) , 036024
Role of frequency-dependent and capacitive tissue properties in spinal cord stimulation models
Objective. Spinal cord stimulation (SCS) models simulate the electric fields (E-fields) generated in targeted tissues, which in turn govern physiological and then behavioral outcomes. Notwithstanding increasing sophistication and adoption in therapy optimization, SCS models typically calculate E-fields using quasi-static approximation (QSA). QSA, as implemented in neuromodulation models, neglects the frequency-dependent tissue conductivity (dispersion), as well as propagation, capacitive, and inductive effects on the E-field. The objective of this study is to calculate the impact of frequency-dependent tissue conductivity and permittivity in SCS models, across a broad frequency range. Approach. We solved a high-resolution RADO-SCS finite element model to simulate E-field magnitudes in spinal column tissues under voltage-controlled (VC) and current-controlled (CC) SCS. Varied combinations of epidural space and dura conductivity based on prior SCS modeling studies (under the QSA-method), as well as values from the Gabriel (1996 Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies) dataset for 1 Hz, 1 kHz, 2.5 kHz, 16.66 kHz, and 1 MHz were considered. We assessed the relative contribution of epidural space and dura permittivity on peak E-field magnitude and neural activation, and compared results to the QSA-method models. Main results. Across published SCS models, the conductivities of epidural space (considered either fat or mixed tissues; 0.025–0.25 S m−1) and dura (0.02–0.6 S m−1) vary by over an order of magnitude, associated with differences in predicted spinal cord peak E-field magnitudes for VC-SCS (6.55–43.71 V m−1 per V) and CC-SCS (10.94–25.20 V m−1 per mA). These literature variations in conductivity and resulting peak E-field magnitude are greater than from epidural/dura tissue dispersion (1 kHz–1 MHz) based on Gabriel (1996 Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies) database (VC-SCS: 7.26–8.09 V m−1 per V; CC-SCS: 21.14–21.25 V m−1 per mA). Changes in E-field magnitudes were not associated with significant changes in relative spatial profiles of the E-field or activating function. The impact of epidural space/dural permittivity (at 1 kHz) on E-field magnitudes and activating function was minimal (⩽1%) for both SCS modes. Significance. The impact of dispersion/permittivity is significantly less than existing variations in tissue conductivities used across SCS modeling studies. As relative E-field or activating function profiles were not significantly changed by tissue conductivities, any impact of neuronal activation thresholds tracks changes in E-field magnitude. We limited our analysis to a single geometry and epidural/dural properties to isolate the impact of QSA.
- 27 May 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (3) , 036024
Role of frequency-dependent and capacitive tissue properties in spinal cord stimulation models
Objective. Spinal cord stimulation (SCS) models simulate the electric fields (E-fields) generated in targeted tissues, which in turn govern physiological and then behavioral outcomes. Notwithstanding increasing sophistication and adoption in therapy optimization, SCS models typically calculate E-fields using quasi-static approximation (QSA). QSA, as implemented in neuromodulation models, neglects the frequency-dependent tissue conductivity (dispersion), as well as propagation, capacitive, and inductive effects on the E-field. The objective of this study is to calculate the impact of frequency-dependent tissue conductivity and permittivity in SCS models, across a broad frequency range. Approach. We solved a high-resolution RADO-SCS finite element model to simulate E-field magnitudes in spinal column tissues under voltage-controlled (VC) and current-controlled (CC) SCS. Varied combinations of epidural space and dura conductivity based on prior SCS modeling studies (under the QSA-method), as well as values from the Gabriel (1996 Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies) dataset for 1 Hz, 1 kHz, 2.5 kHz, 16.66 kHz, and 1 MHz were considered. We assessed the relative contribution of epidural space and dura permittivity on peak E-field magnitude and neural activation, and compared results to the QSA-method models. Main results. Across published SCS models, the conductivities of epidural space (considered either fat or mixed tissues; 0.025–0.25 S m−1) and dura (0.02–0.6 S m−1) vary by over an order of magnitude, associated with differences in predicted spinal cord peak E-field magnitudes for VC-SCS (6.55–43.71 V m−1 per V) and CC-SCS (10.94–25.20 V m−1 per mA). These literature variations in conductivity and resulting peak E-field magnitude are greater than from epidural/dura tissue dispersion (1 kHz–1 MHz) based on Gabriel (1996 Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies) database (VC-SCS: 7.26–8.09 V m−1 per V; CC-SCS: 21.14–21.25 V m−1 per mA). Changes in E-field magnitudes were not associated with significant changes in relative spatial profiles of the E-field or activating function. The impact of epidural space/dural permittivity (at 1 kHz) on E-field magnitudes and activating function was minimal (⩽1%) for both SCS modes. Significance. The impact of dispersion/permittivity is significantly less than existing variations in tissue conductivities used across SCS modeling studies. As relative E-field or activating function profiles were not significantly changed by tissue conductivities, any impact of neuronal activation thresholds tracks changes in E-field magnitude. We limited our analysis to a single geometry and epidural/dural properties to isolate the impact of QSA.
- 21 March 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035004
Computational modeling of neuromuscular activation by transcutaneous electrical nerve stimulation to the lower back
Objectives. Transcutaneous Electrical Nerve Stimulation (TENS) to the lower back is an established electrical therapy for acute and chronic back pain. The efficacy and mechanisms of lower back TENS depend on the penetration depth of electrical current. We compare the intensity and spatial extent (depth) of current flow in the body during TENS with varied electrode positions/shapes on the human back. Materials and Methods. A high-resolution MRI-derived anatomical model of the back was developed, considering major tissue compartments, including skin and muscles. TENS with upper and lower back electrode positions and varied electrode shapes (square, circular, rectangular) were simulated. An exemplary 50 mA current was applied under quasistatic approximation and quasi-uniform electric field assumption of 6.15 V m−1 (low), 12.3 V m−1 (mid), and 24.6 V m−1 (high) neuromuscular activation thresholds were considered. Results. Under all simulated TENS conditions (50 mA), electric fields at the skin exceed the high threshold (consistent with peripheral nerve activation) and at least some muscle regions exceed the mid threshold. Muscle activation was influenced by the anatomy of muscle in the medial-lateral direction and upper-lower back. The electrode shape had minimal effect on deep tissue current penetration. Conclusions. Our simulations indicate significant current penetration into back tissue (electric fields above low threshold) to >8 cm in all TENS conditions simulated, consistent with nerve and muscle activation. Significance. Anatomically precise models of upper and lower back TENS show current penetration to deep muscle, supporting direct muscle stimulation driving clinical benefits.
- 21 March 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035004
Computational modeling of neuromuscular activation by transcutaneous electrical nerve stimulation to the lower back
Objectives. Transcutaneous Electrical Nerve Stimulation (TENS) to the lower back is an established electrical therapy for acute and chronic back pain. The efficacy and mechanisms of lower back TENS depend on the penetration depth of electrical current. We compare the intensity and spatial extent (depth) of current flow in the body during TENS with varied electrode positions/shapes on the human back. Materials and Methods. A high-resolution MRI-derived anatomical model of the back was developed, considering major tissue compartments, including skin and muscles. TENS with upper and lower back electrode positions and varied electrode shapes (square, circular, rectangular) were simulated. An exemplary 50 mA current was applied under quasistatic approximation and quasi-uniform electric field assumption of 6.15 V m−1 (low), 12.3 V m−1 (mid), and 24.6 V m−1 (high) neuromuscular activation thresholds were considered. Results. Under all simulated TENS conditions (50 mA), electric fields at the skin exceed the high threshold (consistent with peripheral nerve activation) and at least some muscle regions exceed the mid threshold. Muscle activation was influenced by the anatomy of muscle in the medial-lateral direction and upper-lower back. The electrode shape had minimal effect on deep tissue current penetration. Conclusions. Our simulations indicate significant current penetration into back tissue (electric fields above low threshold) to >8 cm in all TENS conditions simulated, consistent with nerve and muscle activation. Significance. Anatomically precise models of upper and lower back TENS show current penetration to deep muscle, supporting direct muscle stimulation driving clinical benefits.
- 1 February 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016028
Frequency-dependent phase entrainment of cortical cell types during tACS: computational modeling evidence
Objective. Transcranial alternating current stimulation (tACS) enables non-invasive modulation of brain activity, holding promise for clinical and research applications. Yet, it remains unclear how the stimulation frequency differentially impacts various neuron types. Here, we aimed to quantify the frequency-dependent behavior of key neocortical cell types. Approach. We used both detailed (anatomical multicompartments) and simplified (three compartments) single-cell modeling approaches based on the Hodgkin–Huxley formalism to study neocortical excitatory and inhibitory cells under various tACS intensities and frequencies within the 5–50 Hz range at rest and during basal 10 Hz activity. Main results. L5 pyramidal cells (PCs) exhibited the highest polarizability at direct current, ranging from 0.21 to 0.25 mm and decaying exponentially with frequency. Inhibitory neurons displayed membrane resonance in the 5–15 Hz range with lower polarizability, although bipolar cells had higher polarizability. Layer 5 PC demonstrated the highest entrainment close to 10 Hz, which decayed with frequency. In contrast, inhibitory neurons entrainment increased with frequency, reaching levels akin to PC. Results from simplified models could replicate phase preferences, while amplitudes tended to follow opposite trends in PC. Significance. tACS-induced membrane polarization is frequency-dependent, revealing observable resonance behavior. Whilst optimal phase entrainment of sustained activity is achieved in PC when tACS frequency matches endogenous activity, inhibitory neurons tend to be entrained at higher frequencies. Consequently, our results highlight the potential for precise, cell-specific targeting for tACS.
- 1 February 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016028
Frequency-dependent phase entrainment of cortical cell types during tACS: computational modeling evidence
Objective. Transcranial alternating current stimulation (tACS) enables non-invasive modulation of brain activity, holding promise for clinical and research applications. Yet, it remains unclear how the stimulation frequency differentially impacts various neuron types. Here, we aimed to quantify the frequency-dependent behavior of key neocortical cell types. Approach. We used both detailed (anatomical multicompartments) and simplified (three compartments) single-cell modeling approaches based on the Hodgkin–Huxley formalism to study neocortical excitatory and inhibitory cells under various tACS intensities and frequencies within the 5–50 Hz range at rest and during basal 10 Hz activity. Main results. L5 pyramidal cells (PCs) exhibited the highest polarizability at direct current, ranging from 0.21 to 0.25 mm and decaying exponentially with frequency. Inhibitory neurons displayed membrane resonance in the 5–15 Hz range with lower polarizability, although bipolar cells had higher polarizability. Layer 5 PC demonstrated the highest entrainment close to 10 Hz, which decayed with frequency. In contrast, inhibitory neurons entrainment increased with frequency, reaching levels akin to PC. Results from simplified models could replicate phase preferences, while amplitudes tended to follow opposite trends in PC. Significance. tACS-induced membrane polarization is frequency-dependent, revealing observable resonance behavior. Whilst optimal phase entrainment of sustained activity is achieved in PC when tACS frequency matches endogenous activity, inhibitory neurons tend to be entrained at higher frequencies. Consequently, our results highlight the potential for precise, cell-specific targeting for tACS.
- 1 January 2025
- Published by The City University of New York
"The Inside History of SCS 2” with Elliot Krames
- 1 January 2025
- Published by The City University of New York
"The Inside History of SCS 2” with Elliot Krames
- Open Access
- 24 July 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 041002
Quasistatic approximation in neuromodulation
We define and explain the quasistatic approximation (QSA) as applied to field modeling for electrical and magnetic stimulation. Neuromodulation analysis pipelines include discrete stages, and QSA is applied specifically when calculating the electric and magnetic fields generated in tissues by a given stimulation dose. QSA simplifies the modeling equations to support tractable analysis, enhanced understanding, and computational efficiency. The application of QSA in neuromodulation is based on four underlying assumptions: (A1) no wave propagation or self-induction in tissue, (A2) linear tissue properties, (A3) purely resistive tissue, and (A4) non-dispersive tissue. As a consequence of these assumptions, each tissue is assigned a fixed conductivity, and the simplified equations (e.g. Laplace’s equation) are solved for the spatial distribution of the field, which is separated from the field’s temporal waveform. Recognizing that electrical tissue properties may be more complex, we explain how QSA can be embedded in parallel or iterative pipelines to model frequency dependence or nonlinearity of conductivity. We survey the history and validity of QSA across specific applications, such as microstimulation, deep brain stimulation, spinal cord stimulation, transcranial electrical stimulation, and transcranial magnetic stimulation. The precise definition and explanation of QSA in neuromodulation are essential for rigor when using QSA models or testing their limits.
- 24 July 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 041002
Open AccessQuasistatic approximation in neuromodulation
We define and explain the quasistatic approximation (QSA) as applied to field modeling for electrical and magnetic stimulation. Neuromodulation analysis pipelines include discrete stages, and QSA is applied specifically when calculating the electric and magnetic fields generated in tissues by a given stimulation dose. QSA simplifies the modeling equations to support tractable analysis, enhanced understanding, and computational efficiency. The application of QSA in neuromodulation is based on four underlying assumptions: (A1) no wave propagation or self-induction in tissue, (A2) linear tissue properties, (A3) purely resistive tissue, and (A4) non-dispersive tissue. As a consequence of these assumptions, each tissue is assigned a fixed conductivity, and the simplified equations (e.g. Laplace’s equation) are solved for the spatial distribution of the field, which is separated from the field’s temporal waveform. Recognizing that electrical tissue properties may be more complex, we explain how QSA can be embedded in parallel or iterative pipelines to model frequency dependence or nonlinearity of conductivity. We survey the history and validity of QSA across specific applications, such as microstimulation, deep brain stimulation, spinal cord stimulation, transcranial electrical stimulation, and transcranial magnetic stimulation. The precise definition and explanation of QSA in neuromodulation are essential for rigor when using QSA models or testing their limits.
- Open Access
Novel Evoked Synaptic Activity Potentials (ESAPs) elicited by Spinal Cord Stimulation
Spinal cord stimulation (SCS) evokes fast epidural Evoked Compound Action Potential (ECAPs) that represent activity of dorsal column axons, but not necessarily a spinal circuit response. Using a multimodal approach, we identified and characterized a delayed and slower potential evoked by SCS that reflects synaptic activity within the spinal cord. Anesthetized female Sprague Dawley rats were implanted with an epidural SCS lead, epidural motor cortex stimulation electrodes, an epidural spinal cord recoding lead, an intraspinal penetrating recording electrode array, and intramuscular electromyography (EMG) electrodes in the hindlimb and back. We stimulated the motor cortex or the epidural spinal cord and recorded epidural, intraspinal, and EMG responses. SCS pulses produced characteristic propagating ECAPs (composed of P1, N1, and P2 waves with latencies Significance Statement Spinal cord stimulation (SCS) is an established treatment for chronic pain and has applications to other disorders and neurorehabilitation. Notwithstanding decades of trials and research, questions remain about SCS mechanisms of action - and indicators thereof. Recent technological developments have enabled the detection of Evoked Compound Action Potential (ECAPs) – reflecting synchronous activity of the dorsal column axons activated by SCS. However, ECAP is not a direct measure of sensory processing in the dorsal horn. Here, we identify and characterize a novel electrophysiological signal that is evoked and detectable by epidural SCS electrodes and reflects spinal synaptic currents. This new signal, termed an Evoked Synaptic Activity Potential (ESAP), is thus a novel means with which to interrogate spinal gray matter circuits during SCS.
Open AccessNovel Evoked Synaptic Activity Potentials (ESAPs) elicited by Spinal Cord Stimulation
Spinal cord stimulation (SCS) evokes fast epidural Evoked Compound Action Potential (ECAPs) that represent activity of dorsal column axons, but not necessarily a spinal circuit response. Using a multimodal approach, we identified and characterized a delayed and slower potential evoked by SCS that reflects synaptic activity within the spinal cord. Anesthetized female Sprague Dawley rats were implanted with an epidural SCS lead, epidural motor cortex stimulation electrodes, an epidural spinal cord recoding lead, an intraspinal penetrating recording electrode array, and intramuscular electromyography (EMG) electrodes in the hindlimb and back. We stimulated the motor cortex or the epidural spinal cord and recorded epidural, intraspinal, and EMG responses. SCS pulses produced characteristic propagating ECAPs (composed of P1, N1, and P2 waves with latencies Significance Statement Spinal cord stimulation (SCS) is an established treatment for chronic pain and has applications to other disorders and neurorehabilitation. Notwithstanding decades of trials and research, questions remain about SCS mechanisms of action - and indicators thereof. Recent technological developments have enabled the detection of Evoked Compound Action Potential (ECAPs) – reflecting synchronous activity of the dorsal column axons activated by SCS. However, ECAP is not a direct measure of sensory processing in the dorsal horn. Here, we identify and characterize a novel electrophysiological signal that is evoked and detectable by epidural SCS electrodes and reflects spinal synaptic currents. This new signal, termed an Evoked Synaptic Activity Potential (ESAP), is thus a novel means with which to interrogate spinal gray matter circuits during SCS.
- 12 February 2023
- Published by Wiley in European Journal of Neurology
- Vol. 30 (4) , 802-803
Transcranial direct current stimulation and neurovascular modulation
- 12 February 2023
- Published by Wiley in European Journal of Neurology
- Vol. 30 (4) , 802-803
Transcranial direct current stimulation and neurovascular modulation