Continuous Fault Ride-Through Control of Wind Turbine Using Energy Storage Based DVR
- 7 July 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1576-1580
Abstract
Continuous fault ride-through (CFRT) of wind turbines (WTs) requires WTs to go through continuously from a low voltage stage to a high voltage stage which has a different voltage dynamic process compared with single fault ride-through. And CFRT has a long fault duration. One of the solutions to alleviate the mentioned problems is a dynamic voltage restorer (DVR). However, the expensive cost and large storage requirement of the energy storage system (ESS) in dc link hamper the practical implementation of DVRs. To avoid this drawback, this paper presents a novel control consisting of adaptive mode switching and adaptive coordinated control. The adaptive mode switching control combines advantages of two basic DVR compensation solutions to decrease the DVR injected voltage amplitude and compensates for the phase jump. For CFRT, an adaptive coordination coefficient is introduced to distribute the unbalanced energy between ESS and WT rotor inertia. Furthermore, to validate the operation of the proposed control, simulations and HIL results are provided.Keywords
This publication has 13 references indexed in Scilit:
- Unified Power Quality Conditioner With Advanced Dual Control for Performance Improvement of DFIG-Based Wind FarmIEEE Transactions on Sustainable Energy, 2020
- Isolated H‐bridge DC–DC converter integrated transformerless DVR for power quality improvementIET Power Electronics, 2020
- A Novel DVR-ESS-Embedded Wind-Energy Conversion SystemIEEE Transactions on Sustainable Energy, 2017
- Releasable Kinetic Energy-Based Inertial Control of a DFIG Wind Power PlantIEEE Transactions on Sustainable Energy, 2015
- Transient Reconfiguration and Coordinated Control for Power Converters to Enhance the LVRT of a DFIG Wind Turbine With an Energy Storage DeviceIEEE Transactions on Energy Conversion, 2015
- Impact of Wakes on Wind Farm Inertial ResponseIEEE Transactions on Sustainable Energy, 2013
- Advanced Control Strategy of DFIG Wind Turbines for Power System Fault Ride ThroughIEEE Transactions on Power Systems, 2011
- Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid FaultsIEEE Transactions on Power Electronics, 2011
- Feed-Forward Transient Current Control for Low-Voltage Ride-Through Enhancement of DFIG Wind TurbinesIEEE Transactions on Energy Conversion, 2010
- Decoupled control of a four-leg inverter via a new 4/spl times/4 transformation matrixIEEE Transactions on Power Electronics, 2001