Xunjun Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xunjun Chen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Guangchao Geng
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
7 shared publications - Quanyuan Jiang
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
4 shared publications Quanyuan Jiang
College of Electrical Engineering, Zhejiang University, Hangzhou, China
3 shared publications- Zhigang Liu
Southwest Jiaotong University
2 shared publications Cenfeng Wang
1 shared publication- Guorong Li
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication
Latest Publications
- Open Access
- 18 April 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 177
Inertia-aware frequency regulation for renewable energy cluster with energy storage
- 18 April 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 177
Open AccessInertia-aware frequency regulation for renewable energy cluster with energy storage
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (5) , 3950-3961
Distributed Control of Single-Phase Residential Energy Storages for Three-Phase Unbalance Mitigation With Consumer Benefit Preservation
The uneven allocation of single-phase residential systems and rooftop photovoltaic systems in low-voltage distribution networks leads to three-phase active power unbalance, adversely impacting system stability. Residential energy storage systems, commonly installed by individual consumers to reduce electricity bills, present a potential solution for mitigating this issue. However, existing strategies mostly overlook the economic benefits of consumers, limiting practical adoption. Based on the above analysis, this article proposes a distributed control strategy using single-phase residential energy storage to mitigate three-phase active power unbalance at the point of common connection while preserving consumer benefits. The proposed strategy comprises two stages: day-ahead planning and intraday operation. In the day-ahead stage, the optimal economic operation region is determined to enhance operational flexibility without compromising consumer benefits. Then, a planning curve with optimal bidirectional adjustable capacity is developed as a reference for the intraday operation. During intraday operation, each energy storage autonomously compensates for the unbalanced power based on real-time adjustable potential and unbalance information. Finally, the proposed strategy is validated through simulations and hardware-in-loop experiments, achieving a 12.45% reduction in three-phase active power variance in the IEEE 13-bus feeder, which demonstrates its effectiveness and practical feasibility.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (5) , 3950-3961
Distributed Control of Single-Phase Residential Energy Storages for Three-Phase Unbalance Mitigation With Consumer Benefit Preservation
The uneven allocation of single-phase residential systems and rooftop photovoltaic systems in low-voltage distribution networks leads to three-phase active power unbalance, adversely impacting system stability. Residential energy storage systems, commonly installed by individual consumers to reduce electricity bills, present a potential solution for mitigating this issue. However, existing strategies mostly overlook the economic benefits of consumers, limiting practical adoption. Based on the above analysis, this article proposes a distributed control strategy using single-phase residential energy storage to mitigate three-phase active power unbalance at the point of common connection while preserving consumer benefits. The proposed strategy comprises two stages: day-ahead planning and intraday operation. In the day-ahead stage, the optimal economic operation region is determined to enhance operational flexibility without compromising consumer benefits. Then, a planning curve with optimal bidirectional adjustable capacity is developed as a reference for the intraday operation. During intraday operation, each energy storage autonomously compensates for the unbalanced power based on real-time adjustable potential and unbalance information. Finally, the proposed strategy is validated through simulations and hardware-in-loop experiments, achieving a 12.45% reduction in three-phase active power variance in the IEEE 13-bus feeder, which demonstrates its effectiveness and practical feasibility.
- 6 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Selection and DEA evaluation for renewable energy and energy storage with aggregation suitability
- 6 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Selection and DEA evaluation for renewable energy and energy storage with aggregation suitability
- Open Access
- 28 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1)
Data-driven dynamic modeling for inverter-based resources using neural networks
Dynamic models are a cornerstone of power system stability and control. The growing penetration of inverter-based resources, driven by global decarbonization, significantly complicates power system dynamics. For large-scale power systems, existing dynamic models of these resources have long struggled to accurately capture their complex behaviors, limited primarily by explicit formulations based on simplified physical governing equations. This study presents a data-driven modeling approach that uses neural networks to learn and represent these dynamics exclusively from accessible data. Its tailored architecture combining long short-term memory network for temporal dependencies with a cross layer to model nonlinear feature interactions. Physical constraints from an inverter dynamic model are enforced to enhance consistency and prevent implausible outputs. Validated on a real-world power system (including a wind farm, a photovoltaic power station, and a grid-forming battery energy storage station), the proposed model shows superior accuracy and extrapolates across out-of-distribution scenarios. These findings are further confirmed in a large-scale power system and an inverter-dominated system. The presented approach provides an effective methodology to capture and simulate complex inverter dynamics, enabling more reliable transient stability assessment crucial for the secure operation of future grids.
- 28 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1)
Open AccessData-driven dynamic modeling for inverter-based resources using neural networks
Dynamic models are a cornerstone of power system stability and control. The growing penetration of inverter-based resources, driven by global decarbonization, significantly complicates power system dynamics. For large-scale power systems, existing dynamic models of these resources have long struggled to accurately capture their complex behaviors, limited primarily by explicit formulations based on simplified physical governing equations. This study presents a data-driven modeling approach that uses neural networks to learn and represent these dynamics exclusively from accessible data. Its tailored architecture combining long short-term memory network for temporal dependencies with a cross layer to model nonlinear feature interactions. Physical constraints from an inverter dynamic model are enforced to enhance consistency and prevent implausible outputs. Validated on a real-world power system (including a wind farm, a photovoltaic power station, and a grid-forming battery energy storage station), the proposed model shows superior accuracy and extrapolates across out-of-distribution scenarios. These findings are further confirmed in a large-scale power system and an inverter-dominated system. The presented approach provides an effective methodology to capture and simulate complex inverter dynamics, enabling more reliable transient stability assessment crucial for the secure operation of future grids.
- Open Access
- 23 September 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2560-2574
A coordination control between energy storage based DVR and wind turbine for continuous fault ride‐through
Continuous fault ride‐through (CFRT) issues often arise in wind power systems. CFRT results in continuous voltage fluctuations which is characterized by “initially decreasing and then increasing” and can significantly disrupt the normal operation of wind power systems. To mitigate CFRT related problems, one approach is the utilization of energy storage (ES) based dynamic voltage restorers (DVRs). Nevertheless, the prohibitive costs and substantial ES requirements hamper practical implementation. In this article, a control scheme incorporating adaptive mode switching and coordinated control is proposed. First, the adaptive mode switching control leverages the advantages of two DVR compensation methods to reduce the injected voltage amplitude. The mode switching is activated by the DC link voltage and utilizes the PQR transformation to unlock the phase‐locked loop (PLL). Subsequently, an adaptive coordination coefficient is introduced, which considers the margin of ES regulation power and rotor inertia, to maintain power balance during CFRT. This proposed control strategy not only enables wind turbines to seamlessly ride through continuous faults without disconnecting from the grid but also leads to a reduction in the ES compensation requirement. To validate the effectiveness of the proposed approach, simulations based on Simulink and hardware‐in‐loop (HIL) experiments are conducted.
- 23 September 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2560-2574
Open AccessA coordination control between energy storage based DVR and wind turbine for continuous fault ride‐through
Continuous fault ride‐through (CFRT) issues often arise in wind power systems. CFRT results in continuous voltage fluctuations which is characterized by “initially decreasing and then increasing” and can significantly disrupt the normal operation of wind power systems. To mitigate CFRT related problems, one approach is the utilization of energy storage (ES) based dynamic voltage restorers (DVRs). Nevertheless, the prohibitive costs and substantial ES requirements hamper practical implementation. In this article, a control scheme incorporating adaptive mode switching and coordinated control is proposed. First, the adaptive mode switching control leverages the advantages of two DVR compensation methods to reduce the injected voltage amplitude. The mode switching is activated by the DC link voltage and utilizes the PQR transformation to unlock the phase‐locked loop (PLL). Subsequently, an adaptive coordination coefficient is introduced, which considers the margin of ES regulation power and rotor inertia, to maintain power balance during CFRT. This proposed control strategy not only enables wind turbines to seamlessly ride through continuous faults without disconnecting from the grid but also leads to a reduction in the ES compensation requirement. To validate the effectiveness of the proposed approach, simulations based on Simulink and hardware‐in‐loop (HIL) experiments are conducted.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1576-1580
Continuous Fault Ride-Through Control of Wind Turbine Using Energy Storage Based DVR
Continuous fault ride-through (CFRT) of wind turbines (WTs) requires WTs to go through continuously from a low voltage stage to a high voltage stage which has a different voltage dynamic process compared with single fault ride-through. And CFRT has a long fault duration. One of the solutions to alleviate the mentioned problems is a dynamic voltage restorer (DVR). However, the expensive cost and large storage requirement of the energy storage system (ESS) in dc link hamper the practical implementation of DVRs. To avoid this drawback, this paper presents a novel control consisting of adaptive mode switching and adaptive coordinated control. The adaptive mode switching control combines advantages of two basic DVR compensation solutions to decrease the DVR injected voltage amplitude and compensates for the phase jump. For CFRT, an adaptive coordination coefficient is introduced to distribute the unbalanced energy between ESS and WT rotor inertia. Furthermore, to validate the operation of the proposed control, simulations and HIL results are provided.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1576-1580
Continuous Fault Ride-Through Control of Wind Turbine Using Energy Storage Based DVR
Continuous fault ride-through (CFRT) of wind turbines (WTs) requires WTs to go through continuously from a low voltage stage to a high voltage stage which has a different voltage dynamic process compared with single fault ride-through. And CFRT has a long fault duration. One of the solutions to alleviate the mentioned problems is a dynamic voltage restorer (DVR). However, the expensive cost and large storage requirement of the energy storage system (ESS) in dc link hamper the practical implementation of DVRs. To avoid this drawback, this paper presents a novel control consisting of adaptive mode switching and adaptive coordinated control. The adaptive mode switching control combines advantages of two basic DVR compensation solutions to decrease the DVR injected voltage amplitude and compensates for the phase jump. For CFRT, an adaptive coordination coefficient is introduced to distribute the unbalanced energy between ESS and WT rotor inertia. Furthermore, to validate the operation of the proposed control, simulations and HIL results are provided.
- Open Access
- 2 June 2023
- Published by Institution of Engineering and Technology (IET) in IET Electrical Systems in Transportation
- Vol. 13 (2)
Harmonic stability analysis of single‐phase converters in electric multiple units based on an impedance model with harmonic linearization
Low‐frequency oscillation, harmonic oscillation and harmonic instability issues in railway vehicle‐grid systems pose challenges to the system stability and safe operation. Previous studies constructed the linear time‐invariant impedance model of vehicle‐grid system, which ignored the internal frequency coupling and loss of model accuracy. To fill this gap, the impedance modelling method based on the harmonic linearisation method of the vehicle‐grid system is proposed. The derived model provides a clear physical insight into the harmonic coupling relations between ac and dc variables and improves the model accuracy. Then, a systematic analysis of harmonic stability in the railway vehicle‐grid system is analysed based on the proposed model. The electrical and control parameters on system stability at the frequencies above and below the fundamental frequency are summarised. The mechanisms of these oscillation issues in railway vehicle‐grid systems are then discussed. Finally, the model accuracy and stability analysis results are verified by the frequency scan method and hardware‐in‐the‐loop results.
- 2 June 2023
- Published by Institution of Engineering and Technology (IET) in IET Electrical Systems in Transportation
- Vol. 13 (2)
Open AccessHarmonic stability analysis of single‐phase converters in electric multiple units based on an impedance model with harmonic linearization
Low‐frequency oscillation, harmonic oscillation and harmonic instability issues in railway vehicle‐grid systems pose challenges to the system stability and safe operation. Previous studies constructed the linear time‐invariant impedance model of vehicle‐grid system, which ignored the internal frequency coupling and loss of model accuracy. To fill this gap, the impedance modelling method based on the harmonic linearisation method of the vehicle‐grid system is proposed. The derived model provides a clear physical insight into the harmonic coupling relations between ac and dc variables and improves the model accuracy. Then, a systematic analysis of harmonic stability in the railway vehicle‐grid system is analysed based on the proposed model. The electrical and control parameters on system stability at the frequencies above and below the fundamental frequency are summarised. The mechanisms of these oscillation issues in railway vehicle‐grid systems are then discussed. Finally, the model accuracy and stability analysis results are verified by the frequency scan method and hardware‐in‐the‐loop results.
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3848-3858
A Multi-Frequency Input-Admittance Model of Locomotive Rectifier Considering PWM Sideband Harmonic Coupling in Electrical Railways
Electrical railway harmonic instability issues are common in the high-frequency range. The effective frequency of the traditional converter’s small-signal averaging model is below 1/2 switching frequency since the pulse width modulation (PWM) sideband harmonic components are ignored. In this article, the dynamic propagations of perturbation frequency and the generated PWM sideband components are constructed first. Then the locomotive rectifier’s multi-frequency input-admittance model is derived appropriately. Afterward, an admittance conversion approach is used to convert the multi-frequency model into the single-input–single-output (SISO) model whereas retaining the sideband frequency couplings. The proposed SISO model is more accurate than the traditional small-signal averaging model in the frequency range higher than 1/2 switching frequency. It is found that PWM sideband harmonics dominate the locomotive rectifier’s input-admittance characteristic higher than 1/2 switching frequency. Finally, based on the proposed model, the influence of different switching frequencies, control bandwidths, and traction network impedance on system harmonic stability is revealed by the hardware-in-the-loop (HIL) results.
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3848-3858
A Multi-Frequency Input-Admittance Model of Locomotive Rectifier Considering PWM Sideband Harmonic Coupling in Electrical Railways
Electrical railway harmonic instability issues are common in the high-frequency range. The effective frequency of the traditional converter’s small-signal averaging model is below 1/2 switching frequency since the pulse width modulation (PWM) sideband harmonic components are ignored. In this article, the dynamic propagations of perturbation frequency and the generated PWM sideband components are constructed first. Then the locomotive rectifier’s multi-frequency input-admittance model is derived appropriately. Afterward, an admittance conversion approach is used to convert the multi-frequency model into the single-input–single-output (SISO) model whereas retaining the sideband frequency couplings. The proposed SISO model is more accurate than the traditional small-signal averaging model in the frequency range higher than 1/2 switching frequency. It is found that PWM sideband harmonics dominate the locomotive rectifier’s input-admittance characteristic higher than 1/2 switching frequency. Finally, based on the proposed model, the influence of different switching frequencies, control bandwidths, and traction network impedance on system harmonic stability is revealed by the hardware-in-the-loop (HIL) results.
- Open Access
Impedance Modeling and Stability Analysis of the Converters in a Double-Fed Induction Generator (DFIG)-Based System
Harmonic stability of double-fed induction generators (DFIGs) now has become a significant topic because of its harmful impact on power quality issues of the system. Since the double pulse width modulation (PWM) converter is one of the main harmonic sources in DFIGs, it may cause harmonic instability with increasing harmonic contents. Thus, the modeling and stability analyses of PWM converters in DFIGs are essential steps to assess the harmonic stability of DFIGs. Aiming at dual PWM converters, which include the grid side converter (GSC) and the rotor side converter (RSC), this paper divides converters into two parts: circuit modules and control modules. Closed-loop input impedance models of each module are then derived by means of transfer functions. Hence, the stability of the system can be readily predicted through Nyquist diagrams. The contributions of parameters to the system’s harmonic stability are also identified. Finally, time-domain simulations are conducted in a real-time digital simulation (RTDS) system. Simulation results confirm that the established impedance model can effectively reveal the stability of the DFIG-based system and can give critical conditions for the occurrence of harmonic instability.
Open AccessImpedance Modeling and Stability Analysis of the Converters in a Double-Fed Induction Generator (DFIG)-Based System
Harmonic stability of double-fed induction generators (DFIGs) now has become a significant topic because of its harmful impact on power quality issues of the system. Since the double pulse width modulation (PWM) converter is one of the main harmonic sources in DFIGs, it may cause harmonic instability with increasing harmonic contents. Thus, the modeling and stability analyses of PWM converters in DFIGs are essential steps to assess the harmonic stability of DFIGs. Aiming at dual PWM converters, which include the grid side converter (GSC) and the rotor side converter (RSC), this paper divides converters into two parts: circuit modules and control modules. Closed-loop input impedance models of each module are then derived by means of transfer functions. Hence, the stability of the system can be readily predicted through Nyquist diagrams. The contributions of parameters to the system’s harmonic stability are also identified. Finally, time-domain simulations are conducted in a real-time digital simulation (RTDS) system. Simulation results confirm that the established impedance model can effectively reveal the stability of the DFIG-based system and can give critical conditions for the occurrence of harmonic instability.