Heart Rate and Oxygen Saturation Monitoring With a New Wearable Wireless Device in the Intensive Care Unit: Pilot Comparison Trial (Preprint)
Preprint
- 7 February 2020
- preprint
- Published by JMIR Publications Inc. in JMIR Preprints
Abstract
BACKGROUND Continuous cardiac monitoring with wireless sensors is an attractive option for early detection of arrhythmia and conduction disturbances and the prevention of adverse events leading to patient deterioration. We present a new sensor design (SmartCardia), a wearable wireless biosensor patch, for continuous cardiac and oxygen saturation (SpO2) monitoring. OBJECTIVE This study aimed to test the clinical value of a new wireless sensor device (SmartCardia) and its usefulness in monitoring the heart rate (HR) and SpO2 of patients. METHODS We performed an observational study and monitored the HR and SpO2 of patients admitted to the intensive care unit (ICU). We compared the device under test (SmartCardia) with the ICU-grade monitoring system (Dräger-Healthcare). We defined optimal correlation between the gold standard and the wireless system as <10% difference for HR and <4% difference for SpO2. Data loss and discrepancy between the two systems were critically analyzed. RESULTS A total of 58 ICU patients (42 men and 16 women), with a mean age of 71 years (SD 11), were included in this study. A total of 13.49 (SD 5.53) hours per patient were recorded. This represents a total recorded period of 782.3 hours. The mean difference between the HR detected by the SmartCardia patch and the ICU monitor was 5.87 (SD 16.01) beats per minute (bias=–5.66, SD 16.09). For SpO2, the average difference was 3.54% (SD 3.86; bias=2.9, SD 4.36) for interpretable values. SmartCardia’s patch measures SpO2 only under low-to-no activity conditions and otherwise does not report a value. Data loss and noninterpretable values of SpO2 represented 26% (SD 24) of total measurements. CONCLUSIONS The SmartCardia device demonstrated clinically acceptable accuracy for HR and SpO2 monitoring in ICU patients.Keywords
All Related Versions
- Published version: JMIR Biomedical Engineering, 5 (1), e18158.
This publication has 21 references indexed in Scilit:
- Are current wireless monitoring systems capable of detecting adverse events in high-risk surgical patients? A descriptive studyInjury, 2020
- Vital Signs Monitoring with Wearable Sensors in High-risk Surgical PatientsAnesthesiology, 2020
- Beyond ‘failure to rescue’: the time has come for continuous ward monitoringBritish Journal of Anaesthesia, 2019
- Predictive analytics: beyond the buzzAnnals of Intensive Care, 2019
- Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled TrialJournal of Medical Internet Research, 2018
- Vital signs monitoring and nurse–patient interaction: A qualitative observational study of hospital practiceInternational Journal of Nursing Studies, 2016
- Identification of deteriorating patients on general wards; measurement of vital parameters and potential effectiveness of the Modified Early Warning ScoreJournal of Critical Care, 2012
- Comparison of a new reduced lead set ECG with the standard ECG for diagnosing cardiac arrhythmias and myocardial ischemiaJournal of Electrocardiology, 2002
- ACUTE CORONARY CAREThe Lancet, 1993
- Deriving the 12-lead electrocardiogram from four (EASI) electrodesJournal of Electrocardiology, 1988