Heart Rate and Oxygen Saturation Monitoring With a New Wearable Wireless Device in the Intensive Care Unit: Pilot Comparison Trial
Open Access
- 22 April 2020
- journal article
- research article
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 5 (1) , e18158
Abstract
Background: Continuous cardiac monitoring with wireless sensors is an attractive option for early detection of arrhythmia and conduction disturbances and the prevention of adverse events leading to patient deterioration. We present a new sensor design (SmartCardia), a wearable wireless biosensor patch, for continuous cardiac and oxygen saturation (SpO2) monitoring. Objective: This study aimed to test the clinical value of a new wireless sensor device (SmartCardia) and its usefulness in monitoring the heart rate (HR) and SpO2 of patients. Methods: We performed an observational study and monitored the HR and SpO2 of patients admitted to the intensive care unit (ICU). We compared the device under test (SmartCardia) with the ICU-grade monitoring system (Dräger-Healthcare). We defined optimal correlation between the gold standard and the wireless system as <10% difference for HR and <4% difference for SpO2. Data loss and discrepancy between the two systems were critically analyzed. Results: A total of 58 ICU patients (42 men and 16 women), with a mean age of 71 years (SD 11), were included in this study. A total of 13.49 (SD 5.53) hours per patient were recorded. This represents a total recorded period of 782.3 hours. The mean difference between the HR detected by the SmartCardia patch and the ICU monitor was 5.87 (SD 16.01) beats per minute (bias=–5.66, SD 16.09). For SpO2, the average difference was 3.54% (SD 3.86; bias=2.9, SD 4.36) for interpretable values. SmartCardia’s patch measures SpO2 only under low-to-no activity conditions and otherwise does not report a value. Data loss and noninterpretable values of SpO2 represented 26% (SD 24) of total measurements. Conclusions: The SmartCardia device demonstrated clinically acceptable accuracy for HR and SpO2 monitoring in ICU patients.Keywords
All Related Versions
This publication has 21 references indexed in Scilit:
- Are current wireless monitoring systems capable of detecting adverse events in high-risk surgical patients? A descriptive studyInjury, 2020
- Vital Signs Monitoring with Wearable Sensors in High-risk Surgical PatientsAnesthesiology, 2020
- Beyond ‘failure to rescue’: the time has come for continuous ward monitoringBritish Journal of Anaesthesia, 2019
- Predictive analytics: beyond the buzzAnnals of Intensive Care, 2019
- Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled TrialJournal of Medical Internet Research, 2018
- Vital signs monitoring and nurse–patient interaction: A qualitative observational study of hospital practiceInternational Journal of Nursing Studies, 2016
- Identification of deteriorating patients on general wards; measurement of vital parameters and potential effectiveness of the Modified Early Warning ScoreJournal of Critical Care, 2012
- Comparison of a new reduced lead set ECG with the standard ECG for diagnosing cardiac arrhythmias and myocardial ischemiaJournal of Electrocardiology, 2002
- ACUTE CORONARY CAREThe Lancet, 1993