Practical method for predicting intended gait speed via soleus surface EMG signals
Open Access
- 1 May 2020
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 56 (11) , 528-531
Abstract
The lack of patient effort during robot‐assisted gait training (RAGT) is thought to be the main factor behind unsatisfactory rehabilitative efficacy among hemiparetic stroke patients. A key milestone to implement patient‐driven RAGT is to predict gait intent prior to actual joint movement. Here, the authors propose a method of predicting step speed intent via surface electromyogram (EMG) signals from the soleus. Six lower‐limb muscles were initially evaluated on a treadmill, and the results suggest that the soleus EMG signals correlate well with step speed. The authors further propose a simple linear regression model which predicts subsequent step speed via current soleus EMG signals with over‐ground gait sessions, of ∼0.6. The proposed experimental results and simple prediction model should be applicable for RAGT without significant modifications.Keywords
This publication has 10 references indexed in Scilit:
- Robot-assisted gait training for stroke patients: current state of the art and perspectives of roboticsNeuropsychiatric Disease and Treatment, 2017
- Gait Partitioning Methods: A Systematic ReviewSensors, 2016
- Robotic Technologies and Rehabilitation: New Tools for Stroke Patients’ TherapyBioMed Research International, 2013
- Towards more effective robotic gait training for stroke rehabilitation: a reviewJournal of NeuroEngineering and Rehabilitation, 2012
- Rehabilitation of gait after stroke: a review towards a top-down approachJournal of NeuroEngineering and Rehabilitation, 2011
- The Effectiveness of Locomotor Therapy Using Robotic‐Assisted Gait Training in Subacute Stroke Patients: A Randomized Controlled TrialPM&R, 2009
- Metabolic Costs and Muscle Activity Patterns During Robotic- and Therapist-Assisted Treadmill Walking in Individuals With Incomplete Spinal Cord InjuryPhysical Therapy, 2006
- Electromyographic and kinematic nondisabled gait differences at extremely slow overground and treadmill walking speedsJournal of Rehabilitation Research and Development, 2005
- A robust, real-time control scheme for multifunction myoelectric controlIEEE Transactions on Biomedical Engineering, 2003
- Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life?Gait & Posture, 2000