Jaewook Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaewook Kim has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Seung-Jong Kim
Department of Biomedical Engineering, Korea University College of Medicine, Seoul 02841, Republic of Korea
7 shared publications - Yekwang Kim
Department of Biomedical Engineering, Korea University College of Medicine, Seoul 02841, Republic of Korea
6 shared publications - Juhui Moon
Department of Biomedical Engineering, Korea University College of Medicine, Seoul 02841, Republic of Korea
4 shared publications - Seonghyun Kang
Department of Orthopedic Surgery, Korea University Guro Hospital, Korea University Medicine, Seoul, Republic of Korea
3 shared publications - Hak Jun Kim
Department of Orthopedic Surgery, Korea University Guro Hospital, Seoul, Korea
1 shared publication J. Choi
Center for Bionics, Korea Institute of Science and Technology 5, Hwarang‐ro 14‐gil Seongbuk‐gu Seoul 02792 Republic of Korea
1 shared publication
Latest Publications
- Open Access
Application of Smart Insoles in Assessing Dynamic Stability in Patients with Chronic Ankle Instability: A Comparative Study
Chronic ankle instability (CAI), due to its chronic nature and biomechanical complexity, is well-suited for continuous monitoring and tele-rehabilitation using wearable sensor technology. This study assessed whether a smart insole system, equipped with 4 force-sensing resistor sensors and an inertial measurement unit, combined with functional tests and biomechanical indices, could distinguish CAI patients from healthy controls. A total of 21 CAI patients (23.8 ± 5.1 years) and 16 controls (22.62 ± 2.60 years) completed a battery of functional performance tests while wearing the smart insole system. The results showed an increased medial-lateral pressure ratio in the CAI during heel raise (p = 0.031, effect size = 0.82) and hop tests, suggesting an everted foot position. Significant deviations in center-of-pressure trajectory during double-leg heel raises (p = 0.005, effect size = 1.10) suggested asymmetric motion coordination, while compensatory fluctuations of the lifted limb during single-leg balance tests (p = 0.011, effect size = 1.03) were greater in CAI patients. These findings facilitated the development of features to characterize CAI-specific movement patterns. Together, this system shows promise as a quantitative assessment tool for CAI, supporting improved treatment outcomes through tele-rehabilitation.
Open AccessApplication of Smart Insoles in Assessing Dynamic Stability in Patients with Chronic Ankle Instability: A Comparative Study
Chronic ankle instability (CAI), due to its chronic nature and biomechanical complexity, is well-suited for continuous monitoring and tele-rehabilitation using wearable sensor technology. This study assessed whether a smart insole system, equipped with 4 force-sensing resistor sensors and an inertial measurement unit, combined with functional tests and biomechanical indices, could distinguish CAI patients from healthy controls. A total of 21 CAI patients (23.8 ± 5.1 years) and 16 controls (22.62 ± 2.60 years) completed a battery of functional performance tests while wearing the smart insole system. The results showed an increased medial-lateral pressure ratio in the CAI during heel raise (p = 0.031, effect size = 0.82) and hop tests, suggesting an everted foot position. Significant deviations in center-of-pressure trajectory during double-leg heel raises (p = 0.005, effect size = 1.10) suggested asymmetric motion coordination, while compensatory fluctuations of the lifted limb during single-leg balance tests (p = 0.011, effect size = 1.03) were greater in CAI patients. These findings facilitated the development of features to characterize CAI-specific movement patterns. Together, this system shows promise as a quantitative assessment tool for CAI, supporting improved treatment outcomes through tele-rehabilitation.
- Open Access
- 4 March 2024
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 9 (1) , 45
An Able-Bodied Study for Potential Usage of a Knee Scooter as a Constraint-Induced Movement Therapy (CIMT) Gait Training Device
Post-stroke gait is characterized by slow and asymmetrical hemiparetic gait. This is attributed to the paretic lower limb which has limited plantar propulsion. The most effective method to restore paretic limb function is constraint-induced movement therapy (CIMT), which promotes the usage of the paretic limb by restricting the movement of the unafflicted limb. However, due to the necessity of both lower limbs to perform gait, CIMT methods could not be directly applied for gait rehabilitation. In this study, we explore the feasibility of utilizing a knee scooter as a means to facilitate CIMT gait training. We hypothesize that if lower limb kinematics and muscle activation patterns during gait with a knee scooter match that of natural gait, the knee scooter could be utilized for CIMT gait training. We measured the lower-limb joint angles, plantar force, EMG patterns, stride length, and step times of 13 healthy subjects during gait with a knee scooter and natural gait. The results suggest that the gait patterns while using the knee scooter closely resemble those of natural gait.
- 4 March 2024
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 9 (1) , 45
Open AccessAn Able-Bodied Study for Potential Usage of a Knee Scooter as a Constraint-Induced Movement Therapy (CIMT) Gait Training Device
Post-stroke gait is characterized by slow and asymmetrical hemiparetic gait. This is attributed to the paretic lower limb which has limited plantar propulsion. The most effective method to restore paretic limb function is constraint-induced movement therapy (CIMT), which promotes the usage of the paretic limb by restricting the movement of the unafflicted limb. However, due to the necessity of both lower limbs to perform gait, CIMT methods could not be directly applied for gait rehabilitation. In this study, we explore the feasibility of utilizing a knee scooter as a means to facilitate CIMT gait training. We hypothesize that if lower limb kinematics and muscle activation patterns during gait with a knee scooter match that of natural gait, the knee scooter could be utilized for CIMT gait training. We measured the lower-limb joint angles, plantar force, EMG patterns, stride length, and step times of 13 healthy subjects during gait with a knee scooter and natural gait. The results suggest that the gait patterns while using the knee scooter closely resemble those of natural gait.
- Open Access
- 7 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1363
A Proof of Principle Study Conducted by Community-Dwelling Seniors Using a Novel Passive Gait Assist System
It is vital for rehabilitating patients to perform as many task-related exercises as possible. These patients often need either force or trajectory assistance in order to perform gait. While this can be provided in the form of traditional gait rehabilitation or currently emerging robot-assisted gait training, there is a need for an affordable means to assist gait training. In this study, we present a passive gait assistance device that is composed of a spring-bar system attached to an elastic cord and a specialized shoe. The shoe has two straps attached such that both plantar and dorsiflexion torque can be applied to the user depending on the angle of the pulling force. The merit of the devices is that it is an affordable means to provide the user with gait assistance while allowing some freedom of one’s foot movement. We show that, with 20 community-dwelling seniors, our system successfully produces plantar flexion and dorsiflexion torque according to the gait cycle. Furthermore, electromyography analysis suggests that plantar flexor demand during the late stance phase and dorsiflexor demand during the swing phase are significantly reduced.
- 7 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1363
Open AccessA Proof of Principle Study Conducted by Community-Dwelling Seniors Using a Novel Passive Gait Assist System
It is vital for rehabilitating patients to perform as many task-related exercises as possible. These patients often need either force or trajectory assistance in order to perform gait. While this can be provided in the form of traditional gait rehabilitation or currently emerging robot-assisted gait training, there is a need for an affordable means to assist gait training. In this study, we present a passive gait assistance device that is composed of a spring-bar system attached to an elastic cord and a specialized shoe. The shoe has two straps attached such that both plantar and dorsiflexion torque can be applied to the user depending on the angle of the pulling force. The merit of the devices is that it is an affordable means to provide the user with gait assistance while allowing some freedom of one’s foot movement. We show that, with 20 community-dwelling seniors, our system successfully produces plantar flexion and dorsiflexion torque according to the gait cycle. Furthermore, electromyography analysis suggests that plantar flexor demand during the late stance phase and dorsiflexor demand during the swing phase are significantly reduced.
- Open Access
- 4 May 2023
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 8 (2) , 56
Biomechanical Analysis of the Unaffected Limb While Using a Hands-Free Crutch
Basic human ambulation relies on a bipedal gait, which has been reported to be directly related to quality of life. However, injuries to the lower limb can cause an inability to walk and require non-weightbearing periods to heal. Among the many ambulatory aids, standard axillary crutches are prescribed. However, due to the disadvantages of having to use both hands, a slow gait, pain, nerve damage, and gait patterns that differ from that of healthy subjects, currently, a new generation of ambulatory aids has emerged. Among such aids, hands-free crutches (HFCs) are of particular interest due to their form factor, which does not require the use of the hands and facilitates a bipedal gait. In this study, we present an assessment of whether any different gait patterns, compared to overground gait, appeared on the unaffected limb during walking with an HFC. The spatiotemporal parameters, plantar force, lower-limb joint angles, and EMG patterns were evaluated. In conclusion, the results from 10 healthy subjects suggest that wearing an HFC causes only slight changes in the biomechanical gait patterns examined in the unaffected limb compared with overground walking without an HFC.
- 4 May 2023
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 8 (2) , 56
Open AccessBiomechanical Analysis of the Unaffected Limb While Using a Hands-Free Crutch
Basic human ambulation relies on a bipedal gait, which has been reported to be directly related to quality of life. However, injuries to the lower limb can cause an inability to walk and require non-weightbearing periods to heal. Among the many ambulatory aids, standard axillary crutches are prescribed. However, due to the disadvantages of having to use both hands, a slow gait, pain, nerve damage, and gait patterns that differ from that of healthy subjects, currently, a new generation of ambulatory aids has emerged. Among such aids, hands-free crutches (HFCs) are of particular interest due to their form factor, which does not require the use of the hands and facilitates a bipedal gait. In this study, we present an assessment of whether any different gait patterns, compared to overground gait, appeared on the unaffected limb during walking with an HFC. The spatiotemporal parameters, plantar force, lower-limb joint angles, and EMG patterns were evaluated. In conclusion, the results from 10 healthy subjects suggest that wearing an HFC causes only slight changes in the biomechanical gait patterns examined in the unaffected limb compared with overground walking without an HFC.
- Open Access
- 8 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12574
Biomechanical Task-Based Gait Analysis Suggests ReWalk Gait Resembles Crutch Gait
Current gait rehabilitation strategies rely heavily on motor learning principles, which involve facilitating active patient participation, high-doses of biomechanical task-related motor activities and accurate feedback. Furthermore, appropriate muscle groups need to be recruited for the joint movements that constitute the biomechanical task-related activities in order to effectively promote motor learning. Recently, exoskeleton-type robots utilizing crutches have been incorporated into overground gait rehabilitation programs. However, it is unclear which gait-related tasks are being trained because the joint movements and muscle recruitment patterns deviate from those of natural gait. This raises concerns because repetitive training with these devices may not lead to desirable rehabilitative gains. In this study, we compare the lower limb joint angles and electromyography patterns of healthy subjects walking with and without ReWalk in accordance with the three major biomechanical tasks required by bipedal gait: weight acceptance (WA), single-limb support, and limb advancement. Furthermore, we investigate whether the physical constraints of ReWalk, most noticeably the use of crutches and fixed ankle joints, were responsible for the specific changes by conducting additional walking sessions with either crutches or ankle foot orthoses. The results from the six healthy male volunteers suggest that the gait patterns observed with ReWalk deviate significantly from those of natural gait, particularly during the WA, and closely resemble those of crutch gait.
- 8 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12574
Open AccessBiomechanical Task-Based Gait Analysis Suggests ReWalk Gait Resembles Crutch Gait
Current gait rehabilitation strategies rely heavily on motor learning principles, which involve facilitating active patient participation, high-doses of biomechanical task-related motor activities and accurate feedback. Furthermore, appropriate muscle groups need to be recruited for the joint movements that constitute the biomechanical task-related activities in order to effectively promote motor learning. Recently, exoskeleton-type robots utilizing crutches have been incorporated into overground gait rehabilitation programs. However, it is unclear which gait-related tasks are being trained because the joint movements and muscle recruitment patterns deviate from those of natural gait. This raises concerns because repetitive training with these devices may not lead to desirable rehabilitative gains. In this study, we compare the lower limb joint angles and electromyography patterns of healthy subjects walking with and without ReWalk in accordance with the three major biomechanical tasks required by bipedal gait: weight acceptance (WA), single-limb support, and limb advancement. Furthermore, we investigate whether the physical constraints of ReWalk, most noticeably the use of crutches and fixed ankle joints, were responsible for the specific changes by conducting additional walking sessions with either crutches or ankle foot orthoses. The results from the six healthy male volunteers suggest that the gait patterns observed with ReWalk deviate significantly from those of natural gait, particularly during the WA, and closely resemble those of crutch gait.
- Open Access
Biomechanical Analysis Suggests Myosuit Reduces Knee Extensor Demand during Level and Incline Gait
An FDA-approved soft wearable robot, the Myosuit, which was designed to provide hip and knee extension torque has recently been commercialized. While studies have reported reductions in metabolic costs, increased gait speeds, and improvements in clinical test scores, a comprehensive analysis of electromyography (EMG) signals and joint kinematics is warranted because the recruitment of appropriate muscle groups during physiological movement patterns facilitates effective motor learning. Here, we compared the lower limb joint kinematics and EMG patterns while wearing the Myosuit with that of unassisted conditions when performing level overground and incline treadmill gait. The level overground gait sessions (seven healthy subjects) were performed at self-selected speeds and the incline treadmill gait sessions (four healthy subjects) were performed at 2, 3, 4, and 5 km/h. In order to evaluate how the user is assisted, we conducted a biomechanical analysis according to the three major gait tasks: weight acceptance (WA), single-limb support, and limb advancement. The results from the gait sessions suggest that Myosuit not only well preserves the users’ natural patterns, but more importantly reduce knee extensor demand during the WA phase for both level and incline gait.
Open AccessBiomechanical Analysis Suggests Myosuit Reduces Knee Extensor Demand during Level and Incline Gait
An FDA-approved soft wearable robot, the Myosuit, which was designed to provide hip and knee extension torque has recently been commercialized. While studies have reported reductions in metabolic costs, increased gait speeds, and improvements in clinical test scores, a comprehensive analysis of electromyography (EMG) signals and joint kinematics is warranted because the recruitment of appropriate muscle groups during physiological movement patterns facilitates effective motor learning. Here, we compared the lower limb joint kinematics and EMG patterns while wearing the Myosuit with that of unassisted conditions when performing level overground and incline treadmill gait. The level overground gait sessions (seven healthy subjects) were performed at self-selected speeds and the incline treadmill gait sessions (four healthy subjects) were performed at 2, 3, 4, and 5 km/h. In order to evaluate how the user is assisted, we conducted a biomechanical analysis according to the three major gait tasks: weight acceptance (WA), single-limb support, and limb advancement. The results from the gait sessions suggest that Myosuit not only well preserves the users’ natural patterns, but more importantly reduce knee extensor demand during the WA phase for both level and incline gait.
- Open Access
- 1 May 2020
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 56 (11) , 528-531
Practical method for predicting intended gait speed via soleus surface EMG signals
The lack of patient effort during robot‐assisted gait training (RAGT) is thought to be the main factor behind unsatisfactory rehabilitative efficacy among hemiparetic stroke patients. A key milestone to implement patient‐driven RAGT is to predict gait intent prior to actual joint movement. Here, the authors propose a method of predicting step speed intent via surface electromyogram (EMG) signals from the soleus. Six lower‐limb muscles were initially evaluated on a treadmill, and the results suggest that the soleus EMG signals correlate well with step speed. The authors further propose a simple linear regression model which predicts subsequent step speed via current soleus EMG signals with over‐ground gait sessions, of ∼0.6. The proposed experimental results and simple prediction model should be applicable for RAGT without significant modifications.
- 1 May 2020
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 56 (11) , 528-531
Open AccessPractical method for predicting intended gait speed via soleus surface EMG signals
The lack of patient effort during robot‐assisted gait training (RAGT) is thought to be the main factor behind unsatisfactory rehabilitative efficacy among hemiparetic stroke patients. A key milestone to implement patient‐driven RAGT is to predict gait intent prior to actual joint movement. Here, the authors propose a method of predicting step speed intent via surface electromyogram (EMG) signals from the soleus. Six lower‐limb muscles were initially evaluated on a treadmill, and the results suggest that the soleus EMG signals correlate well with step speed. The authors further propose a simple linear regression model which predicts subsequent step speed via current soleus EMG signals with over‐ground gait sessions, of ∼0.6. The proposed experimental results and simple prediction model should be applicable for RAGT without significant modifications.