Abstract
With the increasing power and torque density of the permanent magnet synchronous motor (PMSM), the windings will experience higher electrical and thermal stresses, which may induce the inter-turn short circuit fault (ISCF). This paper proposes a diagnosis method for the ISCF of the PMSM using α-β plane variables in Field-Oriented Control (FOC). The mathematical model of the PMSM with ISCFs in the α-β plane is derived, and the usable fault features existing in the analytical expressions are analyzed. The second-order generalized integrator (SOGI) is utilized to construct the current residual that includes the short-circuit ratio and short-circuit current for identifying the ISCF. The polarity characteristic presents in the α-β plane voltage with different fault phases are explored. The fault factor for fault location is defined through the combination and logical operation of the characteristic variable. The processed fault factor is the DC quantity that is highly sensitive to the ISCF and is independent of motor parameters. The advantage of the proposed method is that the fault factor is derived from the analytical expression of the voltage and current inherently in the α-β plane, avoiding the iterative calculation, additional hardware, signal injection, and the establishment of specialized models for extracting fault characteristics. The experiment result demonstrates that the proposed method can identify and locate the ISCF, and has the robustness to sudden changes in operating conditions and parameter uncertainties.
Funding Information
  • National Natural Science Foundation of China (52407070)

This publication has 36 references indexed in Scilit: