Order of Magnitude Sensitivity Increase in X-ray Fluorescence Computed Tomography (XFCT) Imaging With an Optimized Spectro-Spatial Detector Configuration: Theory and Simulation
- 6 February 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 33 (5) , 1119-1128
Abstract
The purpose of this study was to increase the sensitivity of XFCT imaging by optimizing the data acquisition geometry for reduced scatter X-rays. The placement of detectors and detector energy window were chosen to minimize scatter X-rays. We performed both theoretical calculations and Monte Carlo simulations of this optimized detector configuration on a mouse-sized phantom containing various gold concentrations. The sensitivity limits were determined for three different X-ray spectra: a monoenergetic source, a Gaussian source, and a conventional X-ray tube source. Scatter X-rays were minimized using a backscatter detector orientation (scatter direction > 110° to the primary X-ray beam). The optimized configuration simultaneously reduced the number of detectors and improved the image signal-to-noise ratio. The sensitivity of the optimized configuration was 10 μg/mL (10 pM) at 2 mGy dose with the mono-energetic source, which is an order of magnitude improvement over the unoptimized configuration (102 pM without the optimization). Similar improvements were seen with the Gaussian spectrum source and conventional X-ray tube source. The optimization improvements were predicted in the theoretical model and also demonstrated in simulations. The sensitivity of XFCT imaging can be enhanced by an order of magnitude with the data acquisition optimization, greatly enhancing the potential of this modality for future use in clinical molecular imaging.Keywords
Funding Information
- NCI fellowship (R25T-CA118681)
- (NIH) (1R01-EB016777)
- (NIBIB) (1K99-EB016059)
This publication has 18 references indexed in Scilit:
- Single-protein nanomechanical mass spectrometry in real timeNature Nanotechnology, 2012
- The Effect of Nanoparticle Size, Shape, and Surface Chemistry on Biological SystemsAnnual Review of Biomedical Engineering, 2012
- Micro-CT enables microlocalisation and quantification of Her2-targeted gold nanoparticles within tumour regionsBritish Journal of Radiology, 2011
- The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo studyPhysics in Medicine & Biology, 2011
- Biodistribution and toxicity of engineered gold nanoparticles: a review of in vitro and in vivo studiesChemical Society Reviews, 2011
- X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in miceJournal of Synchrotron Radiation, 2008
- High-resolution X-ray fluorescence microtomography of homogeneous samplesIEEE Transactions on Nuclear Science, 2000
- Gamma Camera Imaging of Platinum in Tumours and Tissues of Patients after Administration of191Pt-CisplatinActa Oncologica, 1999
- Fluorescence tomography using synchrotron radiation at the NSLSHyperfine Interactions, 1987
- The Scattering of Light by Free Electrons according to Dirac's New Relativistic DynamicsNature, 1928