MAMoiz Ahmad

Moiz Ahmad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Moiz Ahmad has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimized Detector Angular Configuration Increases the Sensitivity of X-ray Fluorescence Computed Tomography (XFCT)

    by Moiz Ahmad, Magdalena Bazalova-Carter, Rebecca Fahrig, Lei Xing

    In this work, we demonstrated that an optimized detector angular configuration based on the anisotropic energy distribution of background scattered X-rays improves X-ray fluorescence computed tomography (XFCT) detection sensitivity. We built an XFCT imaging system composed of a bench-top fluoroscopy X-ray source, a CdTe X-ray detector, and a phantom motion stage. We imaged a 6.4-cm-diameter phantom containing different concentrations of gold solution and investigated the effect of detector angular configuration on XFCT image quality. Based on our previous theoretical study, three detector angles were considered. The X-ray fluorescence detector was first placed at 145 ° (approximating back-scatter) to minimize scatter X-rays. XFCT image quality was compared to images acquired with the detector at 60 ° (forward-scatter) and 90 ° (side-scatter). The datasets for the three different detector positions were also combined to approximate an isotropically arranged detector. The sensitivity was optimized with detector in the 145 ° back-scatter configuration counting the 78-keV gold Kβ1 X-rays. The improvement arose from the reduced energy of scattered X-ray at the 145 ° position and the large energy separation from gold K β1 X-rays. The lowest detected concentration in this configuration was 2.5 mgAu/mL (or 0.25% Au with SNR = 4.3). This concentration could not be detected with the 60 °, 90 °, or isotropic configurations (SNRs = 1.3, 0, 2.3, respectively). XFCT imaging dose of 14 mGy was in the range of typical clinical X-ray CT imaging doses. To our knowledge, the sensitivity achieved in this experiment is the highest in any XFCT experiment using an ordinary bench-top X-ray source in a phantom larger than a mouse ( > 3 cm).


  • Open Access

    X-Ray Luminescence and X-Ray Fluorescence Computed Tomography: New Molecular Imaging Modalities

    by Moiz Ahmad, Guillem Pratx, Magdalena Bazalova, Lei Xing

    X-ray luminescence and X-ray fluorescence computed tomography (CT) are two emerging technologies in X-ray imaging that provide functional and molecular imaging capability. Both emission-type tomographic imaging modalities use external X-rays to stimulate secondary emissions, either light or secondary X-rays, which are then acquired for tomographic reconstruction. These modalities surpass the limits of sensitivity in current X-ray imaging and have the potential of enabling X-ray imaging to extract molecular imaging information. These new modalities also promise to break through the spatial resolution limits of other in vivo molecular imaging modalities. This paper reviews the development of X-ray luminescence and X-ray fluorescence CT and their relative merits. The discussion includes current problems and future research directions and the role of these modalities in future molecular imaging applications.


  • Order of Magnitude Sensitivity Increase in X-ray Fluorescence Computed Tomography (XFCT) Imaging With an Optimized Spectro-Spatial Detector Configuration: Theory and Simulation

    by Moiz Ahmad, Magdalena Bazalova, Liangzhong Xiang, Lei Xing

    The purpose of this study was to increase the sensitivity of XFCT imaging by optimizing the data acquisition geometry for reduced scatter X-rays. The placement of detectors and detector energy window were chosen to minimize scatter X-rays. We performed both theoretical calculations and Monte Carlo simulations of this optimized detector configuration on a mouse-sized phantom containing various gold concentrations. The sensitivity limits were determined for three different X-ray spectra: a monoenergetic source, a Gaussian source, and a conventional X-ray tube source. Scatter X-rays were minimized using a backscatter detector orientation (scatter direction > 110° to the primary X-ray beam). The optimized configuration simultaneously reduced the number of detectors and improved the image signal-to-noise ratio. The sensitivity of the optimized configuration was 10 μg/mL (10 pM) at 2 mGy dose with the mono-energetic source, which is an order of magnitude improvement over the unoptimized configuration (102 pM without the optimization). Similar improvements were seen with the Gaussian spectrum source and conventional X-ray tube source. The optimization improvements were predicted in the theoretical model and also demonstrated in simulations. The sensitivity of XFCT imaging can be enhanced by an order of magnitude with the data acquisition optimization, greatly enhancing the potential of this modality for future use in clinical molecular imaging.