Application of a novel shape-memory alloy concentrator in displaced olecranon fractures: a report of the technique and mid-term clinical results
Open Access
- 2 October 2020
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-8
Abstract
Purpose: Olecranon fracture is a common upper limb fracture, and several surgical approaches have been advocated for its fixation. To overcome the complications associated with common techniques, we present a novel shape-memory alloy concentrator, an alternative for tension band compression, to fix olecranon fracture. Methods: Fifty-seven patients (26 men and 31 women) with olecranon fracture, with a mean age of 45 years, were included in this study. Each patient had undergone open reduction and internal fixation using the Nitinol (Ni-Ti) arched shape-memory connector (ASC). The clinical assessments were performed using the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire and the Mayo Elbow Performance (MEP) score, which were both recorded at the final follow-up visit. Results: The patients were followed up for 44 months on average (range, 31 to 56 months). No patients were lost to follow-up, and all of the olecranon fractures healed in an average of 15 weeks (range, 10 to 34 weeks). The mean DASH score was 8.6 (range, 0 to 32.4), and the mean MEP score was 92.5 (range, 74 to 100). Nine patients showed postoperative complications: prominent hardware (2), infection (1), loss of the range of functional motion (5), and heterotopic ossification (1). Conclusion: The ASC may serve as a favorable device for multi-fragmented and comminuted fractures with rare hardware irritation and may also provide continuous concentrative compression to accelerate osseous healing, thereby aiding the restoration and permitting an early rehabilitation with a low incidence of postoperative complications.Keywords
Funding Information
- National Natural Science Foundation of China (81741111, 81571887)
This publication has 42 references indexed in Scilit:
- Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patientsBMC Musculoskeletal Disorders, 2013
- Olecranon FracturesThe Journal of Hand Surgery, 2013
- Results of open reduction and plate osteosynthesis in comminuted fracture of the olecranonJournal of Shoulder and Elbow Surgery, 2011
- Comment on: Shape memory Ni-Ti alloy swan-like bone connector for treatment of humeral shaft nonunionInternational Orthopaedics, 2010
- Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in ChinaInternational Orthopaedics, 2009
- SHAPE MEMORY ALLOYSOperative Neurosurgery, 2009
- THE EFFECT OF COILING VERSUS CLIPPING OF RUPTURED AND UNRUPTURED CEREBRAL ANEURYSMS ON LENGTH OF STAY, HOSPITAL COST, HOSPITAL REIMBURSEMENT, AND SURGEON REIMBURSEMENT AT THE UNIVERSITY OF FLORIDANeurosurgery, 2009
- Biomaterials in orthopaedicsJournal of The Royal Society Interface, 2008
- Rating systems for evaluation of the elbowBritish Medical Bulletin, 2008
- Is tension band wiring technique the "gold standard" for the treatment of olecranon fractures? A long term functional outcome studyJournal of Orthopaedic Surgery and Research, 2008