Higher resolution cine imaging with compressed sensing for accelerated clinical left ventricular evaluation
- 26 October 2016
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 45 (6) , 1693-1699
Abstract
Purpose: To assess the clinical feasibility of a compressed sensing cine magnetic resonance imaging (MRI) sequence of both high temporal and spatial resolution (CS_bSSFP) in comparison to a balanced steady‐state free precession cine (bSSFP) sequence for reliable quantification of left ventricular (LV) volumes and mass.Materials and Methods: Segmented MRI cine images were acquired on a 1.5T scanner in 50 patients in the LV short‐axis stack orientation using a retrospectively gated conventional bSSFP sequence (generalized autocalibrating partially parallel acquisition [GRAPPA] acceleration factor 2), followed by a prospectively triggered CS_bSSFP sequence with net acceleration factor of 8. Image quality was assessed by published criteria. Comparison of sequences was made in LV volumes and mass, image quality score, quantitative regional myocardial wall motion, and imaging time using Pearson's correlation, Bland–Altman and paired 2‐tailed Student's t‐test.Results: Differences (bSSFP minus CS_bSSFP, mean ± SD) and Pearson's correlations were 14.8 ± 16.3 (P = 0.31) and r = 0.98 (P < 0.0001) for end‐diastolic volume (EDV), 8.4 ± 11.3 (P = 0.54) and r = 0.99 (P < 0.0001) for end‐systolic volume (ESV), –0.4 ± 2.5 (P = 0.87) and r = 0.97 (P < 0.0001) for EF, and –0.9 ± 11.8 (P = 0.92) and r = 0.97 (P < 0.0001) for LV mass. Bland–Altman analyses [bias and (limits of agreement)] revealed strong agreement in LVEDV [8.7 ml, (–12.1, 29.6)], LVESV [4.3 ml, (–11.9, 20.6)], LVEF [‐0.02%, (–5.37, 5.33)], and myocardial mass [‐6.1 g, (–14.7, 26.9)]. Image quality was comparable with a similar mean score (P = 0.42), with a good correlation in image quality observed (r = 0.68, P < 0.0001). Quantitative regional myocardial wall motion demonstrated strong correlation between the sequences (r = 0.87, P < 0.0001). Imaging time was significantly shorter for the CS_bSSFP sequence (1.1 ± 0.5 versus 5.6 ± 1.6 min, P < 0.0001).Conclusion: The novel high‐resolution cine CS_bSSFP accurately and reliably quantitates LV volumes and mass, shortens acquisition times, and is clinically feasible.Level of Evidence: 1Technical Efficacy: Stage 2J. MAGN. RESON. IMAGING 2017;45:1693–1699Keywords
This publication has 20 references indexed in Scilit:
- Volumetric Left Ventricular Ejection Fraction is Superior to 2-Dimensional Echocardiography for Risk Stratification of Patients for Primary Prevention Implantable Cardioverter-Defibrillator ImplantationThe American Journal of Cardiology, 2013
- Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteriaJournal of Cardiovascular Magnetic Resonance, 2013
- Standardized cardiovascular magnetic resonance (CMR) protocols 2013 updateJournal of Cardiovascular Magnetic Resonance, 2013
- Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSEMagnetic Resonance in Medicine, 2012
- Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordingsCardiovascular Ultrasound, 2009
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Determination of cardiac volumes and mass with FLASH and SSFP cine sequences at 1.5 vs. 3 Tesla: A validation studyJournal of Magnetic Resonance Imaging, 2006
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal modelJournal of Magnetic Resonance Imaging, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999